Refine Your Search

Search Results

Viewing 1 to 20 of 20
Journal Article

An Experimental Study on the Fire Response of Vehicles with Compressed Hydrogen Cylinders

2010-04-12
2010-01-0134
To investigate the events that could arise when fighting fires in vehicles with carbon fiber reinforced plastic (CFRP) hydrogen storage cylinders, we conducted experiments to examine whether a hydrogen jet diffusion flame caused by activation of the pressure relief device (PRD) can be extinguished and how spraying water influences the cylinder and PRD. The experiments clarified that the hydrogen jet flame cannot be extinguished easily with water or dry powder extinguishers and that spraying water during activation of the PRD may result in closure of the PRD, but is useful for maintaining the strength of CFRP composite cylinders for vehicles.
Technical Paper

Analysis of HEV Components Efficiency on Fuel Economy

2000-04-02
2000-01-1542
A simulation has been developed at the Japan Automobile Research Institute to predict the fuel economy of HEVs, which are currently being developed in the advanced clean energy vehicle research and development project of MITI/NEDO (ACE Project). The ACE Project includes six types of HEV. The effect of hybrid components efficiency on fuel economy was evaluated by sensitivity coefficient. The results show that the fuel economy of HEVs can improve that of the base vehicle by two times. The sensitivity coefficient of the battery is largest in the FCEV, while that of the motor is largest in the series or series/parallel HEVs.
Technical Paper

Calculation of Hydrogen Consumption for Fuel Cell Vehicles by Exhaust Gas Formulation

2008-04-14
2008-01-0465
The hydrogen consumption of fuel cell vehicles (FCV) can be measured by the gravimetric, pressure and flow methods within a ±1% error. These are the methods acknowledged by ISO and SAE [1, 2], but require the test vehicles to be modified in order to supply hydrogen from an external, rather than the onboard tank. Consequently, technical assistance of the vehicle manufacturer is necessary for this modification, while various components in the test vehicle must be readjusted. For these reasons, a measurement method free of vehicle modification is in great demand. The present study therefore developed an “oxygen balance method” which determines the amount of hydrogen that has reacted with oxygen in the fuel cell stack by measuring the oxygen concentration in exhaust gas.
Journal Article

Combustion Behavior of Leaking Hydrogen and Effects of Ceiling Variations

2011-04-12
2011-01-0254
Hydrogen concentration during combustion in a confined space with a ceiling was investigated. The results indicated that steady-state hydrogen concentration was highest at the ceiling surface for all hydrogen flow rates. When hydrogen concentration was 10-20%, weak flame propagation occurred at the ceiling surface, with the most easily burnable spots being dented areas such as seams, pores and creases on the ceiling surface. The unstable and limited nature of flame propagation at the ceiling surface was attributed to the relationship between temperature and hydrogen concentration in a confined space.
Journal Article

Comparison of fuel economy and exhaust emission tests of 4WD vehicles using single-axis chassis dynamometer and dual-axis chassis dynamometer

2011-08-30
2011-01-2058
The demands of application of dual-axis chassis dynamometers (4WD-CHDY) have increased recently due to the improvement of performance of 4WD-CHDY and an increase in the number of 4WD vehicles which are difficult to convert to 2WD. However, there are few evaluations of any differences between fuel economy and exhaust emission levels in the case of 2WD-CHDY with conversion from 4WD to 2WD (2WD-mode) and 4WD-CHDY without conversion to 2WD (4WD-mode). Fuel economy and exhaust emission tests of 4WD vehicle equipped with a typical 4WD mechanism were performed to investigate any differences between the case of the 2WD-mode and the 4WD-mode. In these tests, we measured ‘work at wheel’ (wheel-work) using wheel torque meters. A comparison of the 2WD-mode and the 4WD-mode reveals a difference of fuel economy (2WD-mode is 1.5% better than that of 4WD-mode) and wheel-work (2WD-mode is 3.9% less than that of 4WD-mode). However, there are almost no differences of exhaust emission levels.
Journal Article

Developing Safety Standards for FCVs and Hydrogen Vehicles

2009-04-20
2009-01-0011
The SAE Fuel Cell Vehicle (FCV) Safety Working Group has been addressing FCV safety for over 9 years. The initial document, SAE J2578, was published in 2002. SAE J2578 has been valuable as a Recommended Practice for FCV development with regard to the identification of hazards and the definition of countermeasures to mitigate these hazards such that FCVs can be operated in the same manner as conventional gasoline internal combustion engine (ICE)-powered vehicles. SAE J2578 is currently being revised so that it will continue to be relevant as FCV development moves forward. For example, test methods were refined to verify the acceptability of hydrogen discharges when parking in residential garages and commercial structures and after crash tests prescribed by government regulation, and electrical requirements were updated to reflect the complexities of modern electrical circuits which interconnect both AC and DC circuits to improve efficiency and reduce cost.
Journal Article

Developing Safety Standards for FCVs and Hydrogen Vehicles

2008-04-14
2008-01-0725
The SAE FCV Safety Working Group has been addressing fuel cell vehicle (FCV) safety for over 8 years. The initial document, SAE J2578, was published in 2002. SAE J2578 has been valuable to FCV development with regard to the identification of hazards and the definition of countermeasures to mitigate these hazards such that FCVs can be operated in the same manner as conventional gasoline internal combustion engine (ICE)-powered vehicles. J2578 is currently being updated to clarify and update requirements so that it will continue to be relevant and useful in the future. An update to SAE J1766 for post-crash electrical safety was also published to reflect unique aspects of FCVs and to harmonize electrical requirements with international standards. In addition to revising SAE J2578 and J1766, the Working Group is also developing a new Technical Information Report (TIR) for vehicular hydrogen systems (SAE J2579).
Technical Paper

Development of Electric Commuter Concept Car “C-ta”

2011-05-17
2011-39-7220
It is becoming more and more necessary to achieve a sustainable low-carbon society by mobility not depending on oil. Electric vehicles are appropriate for such a society, but expensive battery cost and long charging time prohibit the promotion of EVs. One of the solutions is minimizing battery usage by ultra-low fuel efficiency, so we developed an ultrahigh-efficient electric commuter concept car “C-ta”, which requires as small a battery as possible. We assumed that drivers would use the car as a second car for short-distance daily use, such as commuting, shopping, transportation of family, etc. In order to improve fuel efficiency, we mainly considered an ultra-light weight body and chassis, to which CFRP (carbon fiber reinforced plastic) greatly contributes, ultra-low rolling resistance tires, and highly accurate vehicle control technology with four in-wheel motors.
Technical Paper

Development of Fuel Consumption Measurement Methods for Hydrogen Fuel Cell Vehicles

2006-04-03
2006-01-0217
Japan Automobile Research Institute has devised and evaluated the various fuel consumption measurement methods for fuel cell vehicles (FCVs). The examination covers the methods based on measurement of electrical current, hydrogen pressure/temperature, weight and flow rate that are expected to be the same accuracy and convenience as conventional measurement methods such as carbon balance method or fuel flow measurement method. As a result of examining the measurement accuracy for each method with a sonic nozzle used as a standard, it is found that both the pressure method and the weight method fulfill the target accuracy of ±1% and that the flow method is able to improve the accuracy by means of calibration with hydrogen. Also, as a result of applying each method to the fuel consumption test of FCVs, the relative error between the pressure method and weight method is within ±1%.
Technical Paper

Diffusion and Ignition Behavior on the Assumption of Hydrogen Leakage from a Hydrogen-Fueled Vehicle

2007-04-16
2007-01-0428
hydrogen was leaked from the underfloor at a flow rate exceeding 131 NL/min (11.8 g/min), which is the allowable fuel leakage rate at the time of a collision of compressed hydrogen vehicles in Japan, and the resulting distribution of concentration in the engine compartment and the dispersion after stoppage of the leak were investigated. Furthermore, ignition tests were also conducted and the impact on the surroundings (mainly on human bodies) was investigated to verify the safety of the allowable leakage rate. The tests clarified that if hydrogen leaks from the underfloor at a flow rate of 1000 NL/min (89.9 g/min) and is ignited in the engine compartment, people around the vehicle will not be seriously injure. Therefore, it can be said that a flow rate of 131 NL/min (11.8 g/min), the allowable fuel leakage rate at the time of a collision of compressed hydrogen vehicles in Japan, assures a sufficient level of safety.
Technical Paper

Effects of Fuel Properties on the Performance of Advanced Diesel NOx Aftertreatment Devices

2006-10-16
2006-01-3443
In the Japan Clean Air Program II (JCAP II) Diesel WG, effects of fuel properties on the performance of two types of diesel NOx emission aftertreatment devices, a Urea-SCR system and a NOx storage reduction (NSR) catalyst system, were examined. For a Urea-SCR system, the NOx emission reduction performance with and without an oxidation catalyst installed in front of the SCR catalyst at low exhaust gas temperature operation was compared. For an NSR catalyst system, the effect of fuel sulfur on both emissions and fuel economy during 50,000 km driving was examined. Furthermore, effects of other fuel properties such as distillation on exhaust emissions were investigated. The results show that sulfur is the influential factor for both devices. Namely, high NOx emission reduction performance of the Urea-SCR system with the oxidation catalyst at low exhaust gas temperature operation is influenced by sulfur.
Technical Paper

Fire Safety Evaluation of a Vehicle Equipped with Hydrogen Fuel Cylinders: Comparison with Gasoline and CNG Vehicles

2006-04-03
2006-01-0129
In this study, we evaluated the fire safety of vehicles that use compressed hydrogen as fuel. We conducted fire tests on vehicles that used compressed hydrogen and on vehicles that used compressed natural gas and gasoline and compared temperatures around the vehicle and cylinder, internal pressure of the cylinder, irradiant heat around the vehicle, sound pressure levels when the pressure relief device (PRD) was activated, and damage to the vehicle and surrounding flammable objects. The results revealed that vehicles equipped with compressed hydrogen gas cylinders are not more dangerous than CNC or gasoline vehicles, even in the event of a vehicle fire.
Technical Paper

Influence of Ferrocene on Engine and Vehicle Performance

2006-10-16
2006-01-3448
Ferrocene is used as an antiknock additive to replace lead alkyls. To clarify the influence of one metal additive, ferrocene, on engine, following experiments were carried out. The insulation resistance of spark plugs was measured, deposits in the engine were analyzed, and an exhaust emission and fuel economy tests were conducted using gasoline containing ferrocene. The deposit, which contained iron oxides, adhered to the combustion chamber, spark plugs, and exhaust pipe when the engine operated with gasoline containing ferrocene. When vehicles operated with gasoline containing ferrocene, fuel consumption increased and the exhaust temperature rose. In addition, an abnormal electrical discharge pattern was observed in spark plugs operating at high temperatures. Iron-oxide of Fe3O4 is changed into Fe2O3 under high temperatures. Discharge current flows in iron oxides including Fe2O3 because the conductivity of Fe2O3 increases at high temperatures.
Technical Paper

Investigations of Compatibility of ETBE Gasoline with Current Gasoline Vehicles II

2007-07-23
2007-01-2039
JCAPII gasoline workgroup reported vehicle emission study to comprehend the impact of ETBE blending. In previous study, we focused on the compatibility of ETBE blended gasoline with Japanese current gasoline vehicles in-use. Based on recent discussion with ETBE 8% blended gasoline into the market, more information becomes necessary. In this second report, we studied to comprehend the actual emission impact using realistic model fuels using several base stocks. Fuel properties of T50, T90 and aromatic compound content were selected through discussions. Specifications were changed within the range of the market. Both ETBE 0% and 8% were combined for these fuel matrixes. In total, eight fuels and two reference fuels were tested. Two J-ULEV vehicles (one MPI, and a stoichiometric-SIDI) were procured as representatives. We discussed quantitative and qualitative impact toward emissions. Data regarding CO2 and fuel economy change were also reported.
Technical Paper

MR20DD Motoring Fuel Economy Test for 0W-12 and 0W-8 Low Viscosity Engine Oil

2019-12-19
2019-01-2295
The SAE J300 classification was expanded to 0W-12 and 0W-8 viscosity grades in 2015, and lower viscosity engine oils have been studied in the industry. ILSAC GF-6B that will be introduced in 2020 will specify a 0W-16 requirement, but 0W-12 and 0W-8 grades are not considered. Because engine oil equal to or higher than the 0W-20 grade is recommended for almost all engines globally, suitable engine tests for 0W-12 and 0W-8 do not exist. Therefore, the Japan Automobile Manufacturers Association, Petroleum Association of Japan and Society of Automotive Engineers of Japan decided to establish new 0W-12 and 0W-8 low viscosity engine oil specifications. It is referred to as JASO GLV-1, and together with a new fuel economy engine test procedure, these engine oils for better fuel economy will be put on the Japanese market in 2019. Motoring friction torque tests are widely used to ascertain the friction reduction effect of fuel-economy engine oils.
Technical Paper

Safety Evaluation on Fuel Cell Stacks Fire and Toxicity Evaluation of Material Combustion Gas for FCV

2007-04-16
2007-01-0435
Fuel cell vehicles represent a new system, and their safety has not yet been fully proved comparing with present automobile. Thorough safety evaluation is especially needed for the fuel system, which uses hydrogen as fuel, and the electric system, which uses a lot of electricity. The fuel cell stacks that are to be loaded on fuel cell vehicles generate electricity by reacting hydrogen and oxygen through electrolytic polymer membranes which is very thin. The safety of the fuel and electric systems should also be assessed for any abnormality that may be caused by electrolytic polymer membranes for any reasons. The purpose of our tests is to collect basic data to ultimately establish safety standards for fuel cell stacks. Methanol pool flame exposure tests were conducted on stationary use fuel cell stacks of two 200W to evaluate safety in the event of a fire.
Technical Paper

Summary report of Japan Clean Air Program diesel and diesel fuel activities

2007-07-23
2007-01-1952
Diesel emissions are significant issue worldwide, and emissions requirements have become so tough that. the application of after-treatment systems is now indispensable in many countries To meet even more stringent future emissions requirements, it has become apparent that the improvement of market fuel quality is essential as well as the development in engine and exhaust after-treatment technology. Japan Clean Air Program II (JCAP II) is being conducted to assess the direction of future technologies through the evaluation of current automobile and fuel technologies and consequently to realize near zero emissions and carbon dioxide (CO2) emission reduction. In this program, effects of fuel properties on the performance of diesel engines and a vehicle equipped with two types of diesel NOx emission after-treatment devices, a Urea-SCR system and a NOx storage reduction (NSR) catalyst system, were examined.
Technical Paper

Test of Vehicle Ignition Due to Hydrogen Gas Leakage

2006-04-03
2006-01-0126
The distribution of concentrations of hydrogen leaking into the front compartment and the dispersion after the leak was stopped were investigated to obtain basic data for specifying the mounting positions of hydrogen leak detecting sensors and the threshold values of alarms for compressed hydrogen vehicles. Ignition tests were also conducted to investigate the flammability and the environmental impact (i.e. the impact on human bodies). These tests were also conducted with methane to evaluate the protection against hydrogen leaks in vehicles in comparison with natural gas (methane). We found that the concentration of hydrogen in the front compartment reached 23.7 vol% maximum when hydrogen gas was allowed to leak for 600 sec from the center of the bottom of the wheelbase at a rate of 131 NL/min, which is the allowable limit for a fuel leak at the time of collision of compressed hydrogen vehicles in Japan.
Technical Paper

Thermal Behavior in Hydrogen Storage Tank for FCV on Fast Filling (2nd Report)

2008-04-14
2008-01-0463
If a compressed hydrogen tank for vehicles is filled with hydrogen gas more quickly, the gas temperature in the tank will increase. In this study, we conducted hydrogen gas filling tests using the TYPE 3 and TYPE 4 tanks. During the tests, we measured the temperature of the internal liner surface and investigated its relationship with the gas temperature in the tank. We found that the gas temperature in the upper portion of the TYPE 4 tank rose locally during filling and that the temperature of the internal liner surface near that area also rose, resulting in a temperature higher than the gas temperature at the center of the tank. To keep the maximum temperature in the tank below the designed temperature (85°C) during filling and examine the representative tank internal temperatures, it is important to examine filling methods that can suppress local rises of tank internal temperature.
Technical Paper

Validity of Low Ventilation for Accident Processing with Hydrogen Leakage from Hydrogen-Fuelled Vehicle

2013-04-08
2013-01-0211
Appropriate emergency response information is required for first responder before hydrogen fuel cell vehicles will become widespread. This paper investigates experimentally the hydrogen dispersion in the vicinity of a vehicle which accidentally releases hydrogen horizontally with a single volumetric flow of 2000 NL/min in the under-floor section while varying cross and frontal wind effects. This hydrogen flow rate represents normally a full throttle power condition. Forced wind was about maximum 2 m/s. The results indicated that the windward side of the vehicle was safe but that there were chiefly two areas posing risks of fire by hydrogen ignition. One was the leeward side of the vehicle's underbody where a larger region of flammable hydrogen dispersion existed in light wind than in windless conditions. The other was the area around the hydrogen leakage point where most of the leaked hydrogen remained undiffused in an environment with a wind of no stronger than 2 m/s.
X