Refine Your Search

Topic

Search Results

Technical Paper

3-D Multiphase Flow Simulation of Coolant Filling and Deaeration Processes in an Engine Coolant System

2024-01-16
2024-26-0310
The thermal performance of an engine coolant system is efficient when the engine head temperature is maintained within its optimum working range. For this, it is desired that air should not be entrapped in the coolant system which can lead to localized hot spots at critical locations. However, it is difficult to eliminate the trapped air pockets completely. So, the target is to minimize the entrapped air as much as possible during the coolant filling and deaeration processes, especially in major components such as the radiator, engine head, pump etc. The filling processes and duration are typically optimized in an engine test stand along with design changes for augmenting the coolant filling efficiency. However, it is expensive and time consuming to identify air entrapped locations in tests, decide on the filling strategy and make the design changes in the piping accordingly.
Technical Paper

An Evaluation of Glycerin (Glycerol) as a Heavy Duty Engine Antifreeze/Coolant Base

2007-10-29
2007-01-4000
In the early years of antifreeze/coolants (1920s & 30s) glycerin saw some usage, but because of higher cost and weaker freeze point depression, it was not competitive with ethylene glycol. Glycerin is a by-product of the manufacture of biodiesel (fatty acid methyl esters) made by reacting natural vegetable or animal fats with methanol. Biodiesel fuel is becoming increasingly important and is expected to gain a large market share in the next several years. Regular diesel fuels blended with 2%, 5%, and 20% biodiesel are now commercially available. The large amount of glycerin generated from high volume usage of biodiesel fuel has resulted in this chemical becoming cost competitive with the glycols currently used in engine coolants. For this reason, and lower toxicity comparable to that of propylene glycol, glycerin deserves to be reconsidered as a base for antifreeze/coolant.
Technical Paper

An Overview of Onboard Coolant Filtration for Heavy Duty Diesel Engines

2005-05-10
2005-01-2014
Coolant filters have been used for nearly 50 years by heavy duty engine manufacturers but little has been published in the technical literature documenting their performance. In heavy duty cooling systems an extender is periodically added to the system to prevent the coolant from becoming corrosive and replenish additives that stop the build-up of deposits which reduce heat transfer. Not only is the coolant filter the most convenient and reliable method to deliver the extender to the cooling system, it also removes debris from the coolant which can cause deposits and wear, aggravate corrosion, and even plug heat exchangers. Additionally, the used coolant filter serves as a diagnostic trouble shooting tool. This paper concentrates on the value or importance of filtering debris from the coolant of heavy duty diesel engine cooling systems. Published literature is reviewed and recent data from lab testing is reported.
Technical Paper

Analysis and Design Validation of Medium Duty Truck Cooling System

2016-09-27
2016-01-8073
Various 1D simulation tools (KULI & LMS Amesim) and 3D simulation tools (ANSYS FLUENT®) can be used to size and evaluate truck cooling system design. In this paper, ANSYS FLUENT is used to analyze and validate the design of medium duty truck cooling systems. LMS Amesim is used to verify the quality of heat exchanger input data. This paper discusses design and simulation of parent and derivative trucks. As a first step, the parent truck was modeled in FLUENT (using standard' k - ε model) with detailed fan and underhood geometry. The fan is modeled using Multiple Reference Frame (MRF) method. Detailed geometry of heat exchangers is skipped. The heat exchangers are represented by regular shape cell zones with porous medium and dual cell heat exchanger models to account for their contributions to the entire system in both flow and temperature distribution. Good agreement is observed between numerical and experimental engine out temperatures at different engine operating conditions.
Journal Article

Boiling Coolant Vapor Fraction Analysis for Cooling the Hydraulic Retarder

2015-04-14
2015-01-1611
The hydraulic retarder is the most stabilized auxiliary braking system [1-2] of heavy-duty vehicles. When the hydraulic retarder is working during auxiliary braking, all of the braking energy is transferred into the thermal energy of the transmission medium of the working wheel. Theoretically, the residual heat-sinking capability of the engine could be used to cool down the transmission medium of the hydraulic retarder, in order to ensure the proper functioning of the hydraulic retarder. Never the less, the hydraulic retarder is always placed at the tailing head of the gearbox, far from the engine, long cooling circuits, which increases the risky leakage risk of the transmission medium. What's more, the development trend of heavy load and high speed vehicle directs the significant increase in the thermal load of the hydraulic retarder, which even higher than the engine power.
Technical Paper

Cold-end Temperature Control Method for the Engine Exhaust Heat Thermoelectric Module

2014-09-30
2014-01-2343
To make full use of engine exhaust heat and further improve the utilization of the energy efficiency of the heavy truck, thermoelectric module is used to contribute to thermoelectric power generation. The hot-end temperature of the module varies with the engine operating condition because it is connected with the exhaust pipe. The cold-end of the thermoelectric module is mainly cooled by engine cooling system. Increasing the temperature difference between the hot-end and cold-end of the thermoelectric module is a good way to improve the thermoelectric conversion efficiency. For the poor controllability of the hot-end temperature of the thermoelectric module, this study puts forward by lowering the cold-end temperature of the thermoelectric module so as to ensure the improvement of the thermoelectric conversion efficiency. The cooling circle for the cold-end of the thermoelectric module which is independent of the engine cooling system is built.
Technical Paper

Cooling Fan Selection in Power Car Application Using CFD and FEA Analysis

2019-04-02
2019-01-0900
This paper describes the methodology used to select an application-based fan that has optimum operating characteristics in terms of cooling air flow rate, fan power, and noise. The selected fan is then evaluated for structural strength. To evaluate different fans, complete rail coach under-hood simulations were carried out using steady-state 3D computational fluid dynamics (CFD) approach. These simulations considered an actual, highly non-uniform flow field. For each fan option, fan power, air flow rate, and surface acoustic power was evaluated. Pressure profiles on the fan blades were studied to assess the effect of non-uniform downstream air passage designs. Surface acoustic power was calculated using broadband noise source (BNS) model in ANSYS Fluent®. Surface pressure profiles over fan blades imported from 3D CFD were used in finite element analysis (FEA) in ANSYS. Analyses were carried out for blade linear and non-linear properties.
Technical Paper

Energy Saving Analysis of Vehicle Hydraulic Retarder Thermal Management System Based on Rankine Cycle

2016-09-18
2016-01-1941
Vehicle hydraulic retarders are applied in heavy-duty trucks and buses as an auxiliary braking device. In traditional cooling systems of hydraulic retarders, the working fluid is introduced into the heat exchanger to transfer heat to the cooling liquid in circulation, whose heat is then dissipated by the engine cooling system. This prevents the waste heat of the working fluid from being used effectively. In hydraulic retarder cooling system based on the Organic Rankine Cycle, the organic working fluid first transfers heat with the hydraulic retarder working fluid in Rankine cycle, and then outputs power through expansion machine. It can both reduce heat load of the engine cooling system, and enhance thermal stability of the hydraulic retarder while recovering and utilizing braking energy. First of all, according to the target vehicle model, hydraulic retarder cooling system model based on Rankine cycle is established.
Technical Paper

Flux Residue and Migration in Charge Air-Cooled Engines

2020-03-27
2019-01-5083
Traditionally, most charge air coolers (CACs) have been constructed using the Nocolok aluminum brazing process. The Nocolok process uses flux, some of which remains after the manufacturing process, and migrates through the intake tract to the engine during normal use. This migration and deposition on engine components can cause a variety of issues with engine operation. Currently the only alternative to Nocolok brazed CACs for engines sensitive to flux migration is vacuum brazing, which comes at a significant price increase. In the effort to reduce cost and increase efficiency, there is interest in whether a Nocolok brazed CAC with a reduced amount of flux residue can be successfully applied to flux-sensitive engines.
Technical Paper

Heavy Truck Driveline Components Modeling and Thermal Analyzing

2009-10-06
2009-01-2905
In heavy truck driveline system, the components often include clutch, transmission, transfer case, drive shaft, etc. A fluid torque converter could be equipped in front of the transmission in order to improve the starting performance. Meanwhile, a hydraulic retarder could be introduced for auxiliary braking so as to adapt the truck to the brake on long downgrade in mountainous regions. Thus, the driveline heat load would have a notable increase. Both the fluid torque converter and the hydraulic retarder would produce a large quantity of heat, and a special cooling system is needed for adjusting the transmission fluid temperature with which the gains are potentially very large [1]. The heat load for driveline is often calculated based on empirical formula. For the heavy truck, however, if the heat value is underestimated, driveline components would suffer from overheated damage.
Technical Paper

Improvements on the Start Performance of Diesel Engine by Fuel Control Strategy Optimization and Heating Measures

2008-06-23
2008-01-1646
The incomplete combustion and misfire of diesel engine during starting result in unwanted white smoke. The histories of combustion and emission in different phases under different start conditions were studied in this paper. The optimization of the fuel injection control strategy under start conditions was performed. When the diesel engine is started under low temperature, the control strategy adapted to start the engine with a certain constant fuel mass injected per cycle, there may be misfire cycles in the initial period or in the transitional process, which is mainly caused by the mismatch between the fuel mass injected per cycle and the instantaneous engine speed. Therefore, an optimized control strategy was put forward, namely, the engine starts with high fuel mass injection in the first several cycles and then decreases step by step during the transitional period until it operates at idle condition. This strategy was validated to decrease significantly the misfire cycles.
Technical Paper

Integrated Cooling Evaporation System for the Hydraulic Retarder

2015-04-14
2015-01-1612
The hydraulic retarder is a significant auxiliary braking device [1] for the heavy duty vehicle. Traditionally, cooling circulatory system of the hydraulic retarder was coupled with the engine cooling system [2], and the thermal energy of the transmission medium would be cooled by the engine radiator ultimately. For this scheme, radiator's spare heat removal capacity could be fully utilized whereas the cooling system is very complicated and is hard to maintain. Furthermore, the corresponding of thermal management system lags behind the power change of the retarder. In this research, integrated cooling evaporation system is developed for the hydraulic retarder, which makes the cooling water contact with the transmission medium through the stator wall, so that it can rapidly response to the thermal variation of the retarder, keep the stability of the oil temperature and meanwhile reduce the risk of cooling medium leakage.
Technical Paper

Modeling and Analyzing for Hydraulic-Driven Cooling System of Heavy Duty Truck

2016-04-05
2016-01-0222
The heavy duty trucks have large engine power and drive continuously in mountainous area, so the heat dissipation of engine is very important. In the traditional cooling system with fixed transmission ratio fan, the cooling capacity is insufficient and the engine is easy to be over-heated when the engine is working in low speed and heavy load conditions. Owning to the bigger size of electric motor compared to the hydraulic motor, it is not suitably applied to the heavy duty trucks. Contrasted with the electric motor, the hydraulic drive cooling system is widely applied in heavy duty trucks due to smaller size, larger power, continuous speed modulation and flexible installation location. However, the low transmission efficiency of the pump-motor system results in high power consumption of the cooling system. In this paper, the mathematical and simulation model of hydraulic-driven fan cooling system is established for the specific engine.
Journal Article

Multi-Domain Simulation Model of a Wheel Loader

2016-09-27
2016-01-8055
Wheel loader subsystems are multi-domain in nature, including controls, mechanisms, hydraulics, and thermal. This paper describes the process of developing a multi-domain simulation of a wheel loader. Working hydraulics, kinematics of the working tool, driveline, engine, and cooling system are modeled in LMS Imagine.Lab Amesim. Contacts between boom/bucket and bucket/ground are defined to constrain the movement of the bucket and boom. The wheel loader has four heat exchangers: charge air cooler, radiator, transmission oil cooler, and hydraulic oil cooler. Heat rejection from engine, energy losses from driveline, and hydraulic subsystem are inputs to the heat exchangers. 3D CFD modeling was done to calibrate airflows through heat exchangers in LMS Amesim. CFD modeling was done in ANSYS FLUENT® using a standard k - ε model with detailed fan and underhood geometry.
Technical Paper

Numerical and Experimental Investigation on Heat Exchange Performance for Heat Dissipation Module for Construction Vehicles

2017-03-28
2017-01-0624
In this work, a XD132 Road Roller from XCMG in China was employed as a research basis to study the heat exchange performance of the heat dissipation module under varied working conditions. The module in the XD132 consists of a cooling fan and three radiators. At first, the numerical investigation on the elementary units of radiators was performed to obtain Colburn j factor and Fanning friction f factor, which were used for the ε-NTU method to predict the radiator performance. The fan was numerically tested in a wind test tunnel to acquire the performance curve. The performance data from both investigations were transformed into the boundary conditions of the numerical vehicle model in a virtual tunnel. A field experiment was carried out to validate the simulation accuracy, and an entrance coefficient was proposed to discuss the performance regularity under four working conditions.
Technical Paper

Parallel Thermal Management System of the Water Medium Retarder

2018-04-03
2018-01-0777
The thermal management system of the water medium retarder using engine coolant (water and ethylene glycol) as transmission medium, omits oil-water heat exchanger in the structure. When the hydraulic retarder is operated, the valve is connected with the retarder and water pump, and then the engine coolant enters the working chamber. The kinetic energy of the vehicle is converted into internal energy of the coolant, and the heat is discharged to the external environment through the engine thermal management system. The braking torque of the water medium hydraulic retarder is determined by the water medium flow rate in the working chamber. The smaller the valve opening degree, the greater the braking torque and the faster the heating transmission fluid. Small valve opening is not conducive to the loss of heat. It will affect the normal working of the engine and hydraulic retarder.
Technical Paper

Pressure Drop and Heat Transfer Analysis of Power Battery Liquid Cooling System

2022-12-16
2022-01-7122
The battery liquid cooling system can ensure that the battery works within a suitable temperature range, improve the safety performance of the battery system, and ensure the cruising range. This paper introduces a design scheme of a stamped double-parallel liquid cooling plate. Based on the STAR-CCM+ simulation software, a thermal simulation model of the battery management system is established to analyze the thermal behavior of the battery system and to study the effect of the inlet mass flow rate on the temperature of the top surface of the batteries. At the same time, with the analysis of the proportion of pressure drop of each component in the liquid cooling plate, an optimization of inserted part in the liquid cooling plate is proposed. The numerical analysis results are compared with the experimental results of the pressure drop to improve the effectiveness of the optimization scheme.
Technical Paper

Research on Heat Dissipation Performance of Automobile Motor Based on Heat Pipe Optimization Design

2022-03-29
2022-01-0729
In new energy vehicles, the electric motor, as the main power source, is developing toward high power density. However, its heat generation problem always affects the overall performance of the motor, so an efficient motor cooling system is especially important. In desert or water-scarce areas, liquid cooling cannot meet the needs of new energy vehicle motor cooling. When glycol or other liquid coolants are low or depleted, motor heat dissipation becomes less effective. Heat pipe is a heat dissipation technology with advantages such as fast thermal response and light weight. In this paper, by improving the heat pipe arrangement and reducing the overall mass of the heat dissipation system, a heat pipe optimization design based on a drive motor heat dissipation scheme is proposed, and the overall stability of the motor working under high temperature conditions is improved.
Technical Paper

Research on Matching for the Rankine Cycle Evaporate-condensate System of Hydraulic Retarder

2016-09-18
2016-01-1938
The hydraulic retarder is an auxiliary braking device used for commercial vehicle in a long slope brake, and its transmission oil generates a lot of heat in its working process. If the heat of transmission doesn’t go through a reasonable management, it will seriously affect the braking performance of hydraulic retarder. To cool down the transmission oil, it will aggravates the load of the engine cooling system, and the long cooling path sometimes causes heat exchange not timely. When the Rankine cycle is used for cooling the hydraulic retarder transmission oil in virtue of its good heat transfer performance in phase change process, it can make the transmission oil temperature controlled more stable. In this new system, the setting parameters of the Evaporate-condensate system will affect the stability of the transmission oil temperature in the hydraulic retarder inlet and the energy recovery efficiency of the system.
Technical Paper

Research on Solar Thermal Energy Warming Diesel Engine Based on Reverse Heat Transfer of Coolant

2020-04-14
2020-01-1343
In winter, the temperature of the coldest month is below -20°C. Low temperature makes it difficult to start a diesel engine, combust sufficiently, which increases fuel consumption and pollutes the environment. The use of an electric power-driven auxiliary heating system increases the battery load and power consumption. Solar thermal energy has the advantages of easy access, clean and pollution-free. The coolant in the cylinder block of the diesel engine has a large contact area within the cylinder and is evenly distributed, which can be used as a heat transfer medium for the warm-up. A one-dimensional heat transfer model of the diesel engine block for the coolant warm-up is developed, and the total heat required for the warm-up is calculated by an iterative method in combination with the warm-up target.