Technical Paper

3D Simulation Methodology to Predict Passenger Thermal Comfort Inside a Cabin

2021-09-15
2021-28-0132
The vehicle Heating, Ventilation and Air conditioning (HVAC) system is designed to meet both the safety and thermal comfort requirements of the passengers inside the cabin. The thermal comfort requirement, however, is highly subjective and is usually met objectively by carrying out time dependent mapping of parameters like the velocity and temperature at various in-cabin locations. These target parameters are simulated for the vehicle interior for a case of hot soaking and its subsequent cool-down to test the efficacy of the AC system. Typically, AC performance is judged by air temperature at passenger locations, thermal comfort estimation along with time to reach comfortable condition for human. Simulating long transient vehicle cabin for thermal comfort evaluation is computationally expensive and involves complex cabin material modelling.
Technical Paper

Approach to Control the in Cab Noise without Affecting Passenger Comfort in AC Midi Buses

2015-01-14
2015-26-0125
This paper discusses various fruitful iterations / experiments performed to reduce air flow induced noise without compromising on total air flow requirement for thermal comfort and ways to avoid heat ingress inside the bus. Also the paper discusses the devised process for noise reduction through front loading of computer aided engineering and computational fluid dynamics analysis. Air conditioning buses in light commercial vehicle (LCV) segment is growing market in India, especially for applications like staff pick-up and drop, school applications and private fleet owners. The air-conditioning system is typically mounted on bus roof top and located laterally and longitudinally at center. It is an easiest and most feasible way to package air conditioning system to cater the large passenger space (32 to 40 seats) with the conditioned air. This makes air conditioning duct design simple and commercially viable.
Technical Paper

Development of Cost Effective Footpad to Mitigate Lower Leg Injury During Anti Vehicle IED Blast

2013-04-08
2013-01-1246
Improvised Explosive Devices (IEDs) and Anti-Tank (AT) mines are a significant threat for military vehicles and their occupants. These explosive devices are designed for the destruction and damage of armored and other vehicles, by using them in battle fields on routes of army vehicles. The blast event results in effects like shockwave, fragments, fire, gases, blast overpressure as well as the vertical impulse load. A blast event affects occupants inside the vehicle in the form of various types of injuries (lower leg, spinal, chest, head etc) and trauma. The Lower leg is the foremost injured body region in a blast event. The term lower leg is used to designate the tibia, fibula and the foot/ankle complex in this paper. Detonations occurring under a vehicle produce high velocity floorboard flutter/deformation and transmit axial loads to lower leg and create injuries.
Technical Paper

Energy Efficient Air Conditioned Buses

2015-01-14
2015-26-0044
This paper focuses on factors that enhance energy efficiency of air conditioning system on mid-sized, standard and premium buses with engine power from 125 to 280 HP. It covers aspects like light weighting of roof air conditioning system, usage of optimized ducting system with minimal resistance to blowers, deployment of rotary scroll compressor with fast idle control in place of reciprocating piston compressor. The scope of this paper covers AC compressors driven by main engine of vehicle/ bus, study related to auxiliary/donkey engine driven AC compressor is not considered. Context- In order to enhance fuel efficiency in buses an energy efficient air conditioning system should be deployed. This will lead to reduced parasitic load on the engine and translate into direct fuel saving.
Technical Paper

Performance Driven Package Feasibility of Side Restraints Using KBE Tools

2013-01-09
2013-26-0027
Integrating safety features may lead to changes in vehicle interior component designs. Considering this complexity, design guidelines have to take care of aspects which may help in package feasibility studies that consider systems performance requirements. Occupant restraints systems for protection in side crashes generally comprise of Side Airbag (SAB) and Curtain Airbag (IC). These components have to be integrated considering design and styling aspects of interior trims, seat contours and body structure for performance efficient package definition. In side crashes, occupant injury risk increases due to hard contact with intruding structure. This risk could be minimized by cushioning the occupant contact through provision of SAB and Inflatable IC. This paper explains the methodology for deciding the package definitions using Knowlwdge Based Engineering (KBE) tools.
Journal Article

Practical Approach to Develop Low Cost, Energy Efficient Cabin Heating for Extreme Cold Operating Environment

2011-04-12
2011-01-0132
In cold climatic regions (25°C below zero) thermal comfort inside vehicle cabin plays a vital role for safety of driver and crew members. This comfortable and safe environment can be achieved either by utilizing available heat of engine coolant in conjunction with optimized in cab air circulation or by deploying more costly options such as auxiliary heaters, e.g., Fuel Fired, Positive Temperature Coefficient heaters. The typical vehicle cabin heating system effectiveness depends on optimized warm/hot air discharge through instrument panel and foot vents, air directivity to occupant's chest and foot zones and overall air flow distribution inside the vehicle cabin. On engine side it depends on engine coolant warm up and flow rate, coolant pipe routing, coolant leakage through engine thermostat and heater core construction and capacity.