Refine Your Search

Search Results

Viewing 1 to 8 of 8
Technical Paper

Acoustic Attenuation Performance of Perforated Absorbing Silencers

2001-04-30
2001-01-1435
The acoustic attenuation performance of a single-pass, perforated concentric silencer filled with continuous strand fibers is investigated theoretically and experimentally. One-dimensional analytical and three-dimensional boundary element methods are employed to predict the acoustic attenuation in the absence of mean flow. Measured complex characteristic impedance and wave number are used to account for the wave propagation through absorbing fiber. The perforation impedance facing the fiber is also presented in terms of the complex characteristic impedance and wave number. The effects of perforate duct porosity and the fiber density are examined. Comparisons of predictions with the experiments illustrate the need for multidimensional analysis at higher frequencies, while the one-dimensional treatment provides a reasonable accuracy at lower frequencies, as expected. The study also shows a significant improvement in the acoustic attenuation of the silencer due to fiber absorption.
Technical Paper

Acoustic Characteristics of Coupled Dissipative and Reactive Silencers

2003-05-05
2003-01-1643
The acoustic characteristics of a hybrid silencer consisting of two dissipative chambers and a Helmholtz resonator are investigated first computationally and experimentally. Complex wave number and characteristic impedance are used for the dissipative chambers to account for the wave propagation through absorbing material. Three-dimensional boundary element method (BEM) is employed to predict the transmission loss in the absence of mean flow and the predictions are compared with the experimental results obtained from an impedance tube setup. Noting that the long connecting tube between acoustic elements may reduce the transmission loss near the resonance frequency, two alternative hybrid silencers with short connecting tubes are also investigated by BEM. The present study shows the effectiveness of hybrid silencers over a wide frequency range and demonstrates the importance of understanding each acoustic element, as well as their interaction in designing silencers.
Journal Article

Acoustic Emission Processing for Turbocharged GDI Engine Control Applications

2015-04-14
2015-01-1622
In the field of passenger car engines, recent research advances have proven the effectiveness of downsized, turbocharged and direct injection concepts, applied to gasoline combustion systems, to reduce the overall fuel consumption while respecting particularly stringent exhaust emissions limits. Knock and turbocharger control are two of the most critical factors that influence the achievement of maximum efficiency and satisfactory drivability, for this new generation of engines. The sound emitted from an engine encloses many information related to its operating condition. In particular, the turbocharger whistle and the knock clink are unmistakable sounds. This paper presents the development of real-time control functions, based on direct measurement of the engine acoustic emission, captured by an innovative and low cost acoustic sensor, implemented on a platform suitable for on-board application.
Technical Paper

Approximating Engine Tailpipe Orifice Noise Sound Quality using a Surge Tank and In-Duct Measurements

2003-05-05
2003-01-1641
Because of the need to safely vent exhaust gases, most engine dynamometer facilities are not well suited to measuring engine exhaust orifice noise. Depending on the location of the dyno facility within the building, the exhaust system may need to be extended in order to properly vent the exhaust fumes. This additional ducting changes the acoustic modes of the exhaust system which will change the measured orifice noise. Duct additions downstream of the original orifice location also alter the termination impedance such that in-duct pressure measurements with and without the extended exhaust system can vary significantly. In order to minimize the effect of the building's exhaust system on the desired engine exhaust system measurements, the present approach terminates the engine exhaust into a large enclosed volume or surge tank before venting the gases into the building's ventilation system.
Journal Article

Circumferential Variation of Noise at the Blade-Pass Frequency in a Turbocharger Compressor with Ported Shroud

2021-08-31
2021-01-1044
The ported shroud casing treatment for turbocharger compressors offers a wider operating flow range, elevated boost pressures at low compressor mass flow rates, and reduced broadband whoosh noise in spark-ignition internal combustion engine applications. However, the casing treatment elevates tonal noise at the blade-pass frequency (BPF). Typical rotational speeds of compressors employed in practice push BPF noise to high frequencies, which then promote multi-dimensional acoustic wave propagation within the compressor ducting. As a result, in-duct acoustic measurements become sensitive to the angular location of pressure transducers on the duct wall. The present work utilizes a steady-flow turbocharger gas stand featuring a unique rotating compressor inlet duct to quantify the variation of noise measured around the duct at different angular positions.
Technical Paper

Design of a Hybrid Exhaust Silencing System for a Production Engine

2005-05-16
2005-01-2349
A prototype hybrid exhaust silencing system consisting of dissipative and reactive components is designed based on the boundary element method (BEM) with a specific emphasis on its acoustic performance as evaluated relative to a production system. The outer dimensions of the prototype system are comparable to its production counterpart, which has two silencers connected by a pipe. The predicted transmission loss by BEM for the prototype is compared with the experimental results in an impedance tube for both the prototype and production hardware, providing a design guidance for the former. The sound pressure levels measured at the tailpipe exit during the engine ramp-up experiments in a dynamometer laboratory are presented to compare the two systems, providing the final assessment.
Journal Article

Instabilities at the Low-Flow Range of a Turbocharger Compressor

2013-05-13
2013-01-1886
The acoustic and performance characteristics of an automotive centrifugal compressor are studied on a steady-flow turbocharger test bench, with the goal of advancing the current understanding of compression system instabilities at the low-flow range. Two different ducting configurations were utilized downstream of the compressor, one with a well-defined plenum (large volume) and the other with minimized (small) volume of compressed air. The present study measured time-resolved oscillations of in-duct and external pressure, along with rotational speed. An orifice flow meter was incorporated to obtain time-averaged mass flow rate. In addition, fast-response thermocouples captured temperature fluctuations in the compressor inlet and exit ducts along with a location near the inducer tips.
Technical Paper

Study of Whistles with a Generic Sidebranch

1999-05-17
1999-01-1814
The coupling of shear layer instabilities with the acoustic resonances at the interface of two ducts, a main duct and a connecting sidebranch, leads to whistle noise. The present study investigates experimentally the mechanism of such pure tone noise. A generic sidebranch adapter is fabricated to allow for: (1) the ability to mount downstream of the throttle body in the induction system of a production engine; (2) the adjustment of sidebranch length; and (3) the changes in the diameter of the branch duct. Experiments are conducted both in a flow facility and an engine dynamometer facility for the same set of flow rates. The correlation of the whistle noise between these two facilities is examined in terms of frequency and the dimensionless numbers, including Strouhal and Mach.
X