These recommendations cover the general field of airplane cabin pressurization equipment and are subdivided as follows: GENERAL REQUIREMENTS FOR PRESSURIZED AIRPLANES CABIN AIR COMPRESSORS CABIN PRESSURE REGULATING EQUIPMENT ENGINE BLEED AIR DUCT SYSTEMS CABIN PRESSURE DUCTING SYSTEM
These recommendations cover the general field of airplane cabin pressurization equipment and are subdivided as follows: GENERAL REQUIREMENTS FOR PRESSURIZED AIRPLANES CABIN AIR COMPRESSORS CABIN PRESSURE REGULATING EQUIPMENT ENGINE BLEED AIR DUCT SYSTEMS CABIN PRESSURE DUCTING SYSTEM
This SAE Aerospace Information Report (AIR) provides information on aircraft cabin air quality, including: Origins of chemical airborne contaminants during routine operating and failure conditions. Exposure control measures, including design, maintenance, and worker training/education. This AIR does not deal with airflow requirements.
This publication formalizes the applicable design concepts considered acceptable for "draw-through" cooling of electronic (avionic) equipment installed in subsonic and supersonic commercial jet transports. Methods other than draw-through cooling are covered in AIR 728A for high Mach number aircraft.
This document considers the cooling of equipment installed in equipment centers, which usually consist of rack-mounted equipment and panel mounted equipment in the flight deck. Instances where these two locations result in different requirements are identified. This document generally refers to the cooled equipment as E/E equipment, denoting that both electrical and electronic equipment is considered, or as an E/E equipment line-replaceable-unit (LRU). The majority of cooled equipment takes the form of LRUs. The primary focus of this document is E/E equipment which uses forced air cooling to keep the equipment within acceptable environmental limits. These limits ensure the equipment operates reliably and within acceptable tolerances. Cooling may be supplied internally or externally to the E/E equipment case. Some E/E equipment is cooled solely by natural convection, conduction, and radiation to the surrounding environment.
Recommendations of this ARP refer specifically to the application of closed cycle vapor cycle refrigeration systems as a source of cooling in an aircraft air conditioning system. General recommendations for an air conditioning system which may include a vapor cycle system as a cooling source are included in ARP 85, Air Conditioning Equipment, General Requirements for Subsonic Airplanes, ARP 292, Air Conditioning, Helicopters, General Requirements For, and AIR 806, Air Conditioning Design Information for Cargo and High Density Passenger Transport Airplanes, and are not included herein.
Recommendations of this ARP refer specifically to the application of closed cycle vapor cycle refrigeration systems as a source of cooling in an aircraft air conditioning system. General recommendations for an air conditioning system which may include a vapor cycle system as a cooling source are included in ARP 85, Air Conditioning Equipment, General Requirements for Subsonic Airplanes, ARP 292, Air Conditioning, Helicopters, General Requirements For, and AIR 806, Air Conditioning Design Information for Cargo and High Density Passenger Transport Airplanes, and are not included herein.
Recommendations of this ARP refer specifically to the application of closed cycle vapor cycle refrigeration systems as a source of cooling in an aircraft air conditioning system. General recommendations for an air conditioning system which may include a vapor cycle system as a cooling source are included in ARP85, Air Conditioning Equipment, General Requirements for Subsonic Airplanes, ARP292, Air Conditioning, Helicopters, General Requirements For, and AIR806, Air Conditioning Design Information for Cargo and High Density Passenger Transport Airplanes, and are not included herein. Vapor cycle refrigeration system design recommendations are presented in this ARP in the following general areas: a SYSTEM Design Recommendations: (See Section 3) b COMPONENT Design Recommendations: (See Section 4) c Desirable Design Features: (See Section 5)
The purpose of this SAE Aerospace Recommended Practice (ARP) is to establish recommendations for the design, installation and testing of air vehicle vapor cycle refrigeration systems. These recommendations are representative of the refrigerant cycles.
The purpose of this SAE Aerospace Recommended Practice (ARP) is to establish recommendations for the design, installation and testing of air vehicle vapor cycle refrigeration systems. These recommendations are representative of the refrigerant cycles.