Refine Your Search

Topic

Search Results

Standard

APPLICATION TESTING OF OIL TO AIR OIL COOLERS FOR COOLING PERFORMANCE

1985-11-01
HISTORICAL
J1468_198511
This Recommended Practice is applicable to oil to air oil coolers installed on mobile or stationary equipment. This document outlines the method of procuring the test data to determine operating characteristics of the oil cooling system and the interpretation of the test results.
Standard

APPLICATION TESTING OF OIL-TO-AIR OIL COOLERS FOR COOLING PERFORMANCE

1993-05-20
HISTORICAL
J1468_199305
This SAE Recommended Practice is applicable to oil-to-air oil coolers installed on mobile or stationary equipment. This document outlines the method of procuring the test data to determine operating characteristics of the oil cooling system and the interpretation of the test results.
Standard

Application Testing of Oil-to-Water Oil Coolers for Heat Transfer Performance

2005-06-21
HISTORICAL
J2414_200506
This SAE Recommended Practice is applicable to oil-to-water oil coolers installed on mobile or stationary equipment. Such oil coolers may be used for the purpose of cooling automatic transmission fluid, hydraulic system oil, retarder system fluid, etc. This document outlines the methods of procuring the test data to determine the operating characteristics of the oil cooling system and the interpretation of the results. For information regarding application testing of oil-to-air oil coolers for heat transfer performance, see SAE J1468.
Standard

Application Testing of Oil-to-Water Oil Coolers for Heat Transfer Performance

1999-03-01
HISTORICAL
J2414_199903
This SAE Recommended Practice is applicable to oil-to-water oil coolers installed on mobile or stationary equipment. Such oil coolers may be used for the purpose of cooling automatic transmission fluid, hydraulic system oil, retarder system fluid, etc. This document outlines the methods of procuring the test data to determine the operating characteristics of the oil cooling system and the interpretation of the results. For information regarding application testing of oil-to-air oil coolers for heat transfer performance, see SAE J1468.
Standard

Charge Air Cooler Internal Cleanliness, Leakage, and Nomenclature

2019-09-05
CURRENT
J1726_201909
This SAE Recommended Practice provides test methods and criteria for evaluating the internal cleanliness and air leakage for engine charge air coolers. This SAE Recommended Practice also provides nomenclature and terminology in common use for engine charge air coolers, related charge air cooling system components, and charge air cooling system operational performance parameters.
Standard

Charge Air Cooler Internal Cleanliness, Leakage, and Nomenclature

2010-02-15
HISTORICAL
J1726_201002
This SAE Recommended Practice provides test methods and criteria for evaluating the internal cleanliness and air leakage. This SAE Recommended Practice also provides nomenclature and terminology in common use for engine charge air coolers, related charge air cooling system components, and charge air cooling system operational performance parameters.
Standard

Charge Air Cooler Internal Cleanliness, Leakage, and Nomenclature

2015-07-01
HISTORICAL
J1726_201507
This SAE Recommended Practice provides test methods and criteria for evaluating the internal cleanliness and air leakage for engine charge air coolers. This SAE Recommended Practice also provides nomenclature and terminology in common use for engine charge air coolers, related charge air cooling system components, and charge air cooling system operational performance parameters.
Standard

ENGINE COOLING FAN STRUCTURAL ANALYSIS

1982-04-01
HISTORICAL
J1390_198204
It is necessary to identify and attempt to evaluate the characteristics of an application which can have an effect on fan durability. Failures almost always occur in fatigue, so careful attention should be paid to avoid resonance or forced vibration of the fan. This section considers vibrational inputs, fan natural frequencies, and operating speed as part of the initial structural integrity analysis. A fan application fact sheet (Table 1) is recommended as a form to communicate between user and fan supplier.
Standard

Electric Drive Cooling Fan Motor Mounting

2010-07-08
HISTORICAL
J2873_201007
This SAE Recommended Practice is applicable to Electric Drive Cooling Fan Assemblies used in Light Duty vehicle cooling systems (typically, passenger cars and light duty trucks). This document outlines the Electric Drive Cooling Fan Motor Mounting interface characteristics such that a common standard is possible.
Standard

Electric Drive Cooling Fan Motor Mounting

2016-03-11
CURRENT
J2873_201603
This SAE Recommended Practice is applicable to Electric Drive Cooling Fan Assemblies used in Light Duty vehicle cooling systems (typically, passenger cars and light duty trucks). This document outlines the Electric Drive Cooling Fan Motor Mounting interface characteristics such that a common standard is possible.
Standard

Engine Cooling Fan Structural Analysis

2012-01-09
HISTORICAL
J1390_201201
Three levels of fan structural analysis are included in this practice: 1 Initial Structural Integrity 2 In-vehicle Testing 3 Durability Test Methods The Initial Structural Integrity section describes analytical and test methods used to predict potential resonance and, therefore, possible fatigue accumulation. The In-vehicle (or machine) section enumerates the general procedure used to conduct a fan strain gage test. Various considerations that may affect the outcome of strain gage data have been described for the user of this procedure to adapt/discard depending on the particular application. The Durability Test Methods section describes the detailed test procedures that may be used depending on type of fan, equipment availability, and end objective. Each of the previous levels builds upon information derived from the previous level. Engineering judgment is required as to the applicability of each level to a different vehicle environment or a new fan design.
Standard

Exhaust Gas Recirculation (EGR) Cooler Nomenclature and Application

2011-11-02
HISTORICAL
J2914_201111
This document provides an overview on how and why EGR coolers are utilized, defines commonly used nomenclature, discusses design issues and trade-offs, and identifies common failure modes. The reintroduction of exhaust gas into the combustion chamber is just one component of the emission control strategy for internal combustion (IC) engines, both diesel and gasoline, and is useful in reducing exhaust port emission of Nitrogen Oxides (NOx). Other means of reducing NOx exhaust port emissions are briefly mentioned, but beyond the scope of this document.
Standard

Exhaust Gas Recirculation (EGR) Cooler Nomenclature and Application

2022-11-22
CURRENT
J2914_202211
This document provides an overview on how and why EGR coolers are utilized, defines commonly used nomenclature, discusses design issues and trade-offs, and identifies common failure modes. The reintroduction of selectively cooled exhaust gas into the combustion chamber is just one component of the emission control strategy for internal combustion (IC) engines, both diesel and gasoline, and is useful in reducing exhaust port emission of nitrogen oxides (NOx). Other means of reducing NOx exhaust port emissions are briefly mentioned, but beyond the scope of this document.
Standard

Exhaust Gas Recirculation (EGR) Cooler Nomenclature and Application

2016-08-23
HISTORICAL
J2914_201608
This document provides an overview on how and why EGR coolers are utilized, defines commonly used nomenclature, discusses design issues and trade-offs, and identifies common failure modes. The reintroduction of exhaust gas into the combustion chamber is just one component of the emission control strategy for internal combustion (IC) engines, both diesel and gasoline, and is useful in reducing exhaust port emission of Nitrogen Oxides (NOx). Other means of reducing NOx exhaust port emissions are briefly mentioned, but beyond the scope of this document.
Standard

Glossary of Engine Cooling System Terms

2019-04-22
HISTORICAL
J1004_201904
The objective of this glossary is to establish uniform definitions of parts and terminology for engine cooling systems. Components included are all those through which engine coolant is circulated: water pump, engine oil cooler, transmission and other coolant-oil coolers, charge air coolers, core engine, thermostat, radiator, external coolant tanks, and lines connecting them.
X