Refine Your Search

Search Results

Viewing 1 to 6 of 6
Technical Paper

Columbus Active Thermal Control System - Final Integration, Test and Mission Preparation

2007-07-09
2007-01-3030
Columbus has been delivered to Kennedy Space Center (KSC) in summer 2006 for final integration, test and mission preparation. In the frame of these “last” phase activities also the Active Thermal Control System (ATCS) had to be finalized and prepared for the launch resp. mission. Due to unexpected late failures resp. malfunctions detected on component/unit level of the ATCS, refurbishment, integration / exchange of the relevant components and re-testing of their system level functions had to be done. Moreover, the still outstanding system level fluid leakage test of the ATCS had to be revised and completed. In addition to the required late refurbishment, integration and test activities, in certain cases also operational workarounds had to be evaluated. They should help to cope with similar contingency situations during operation of the ATCS on-orbit.
Technical Paper

Columbus Environmental Control System Tests - Verification of ATCS and ECLSS Performance

2005-07-11
2005-01-3117
Verification of the Integrated Overall Thermal Mathematical Model (IOTMM) is one of the last tasks in the thermal and environmental control area of the Columbus module. For this purpose a specific test covering as well thermal-hydraulic performance tests as Environmental Control and Life Support (ECLS) cabin temperature control functions has been defined and performed on the european Columbus Protoflight Model (PFM) in Bremen in 2003. This Environmental Control System test was successful for all Active Thermal Control System (ATCS) related thermal-hydraulic functions and could provide sufficient data for a proper IOTMM correlation. However, it failed to verify the ECLS related functions as cabin temperature control and ventilation. Data, which have been generated during this first test, could not be used for a successful IOTMM correlation related to ECLS subsystem performance and modelling.
Technical Paper

Columbus Launch Preparation - Final System ATCS Tests Summary and Lessons Learned

2008-06-29
2008-01-2033
Final preparation and configuration of the Columbus module at the Kennedy Space Center (KSC) required the performance of system level tests with the Active Thermal Control System (ATCS). These tests represented the very last system level activities having been concluded on the Columbus module before handover to NASA for space shuttle integration. Those very last tests, performed with the ATCS comprised the final ATCS Leakage Test, the final calibration and adjustment of the Water Flow Selection Valves (WFSV) and Water On/Off Valves (WOOV) as well as a sophisticated ATCS Residual Air Removal test. The above listed tests have been successfully performed and test data evaluated for verification closeout as well as input delivery for operational Flight Rules and Procedures. Some of the above mentioned tests have been performed the first time hence, a succeeding lessons learned collection followed in order to improve the perspectives of future tests.
Technical Paper

Development of a Urine and Waste Water Separator

1996-07-01
961407
A new configuration of centrifugal waste liquid separator is presently under development in Microtecnica. Its main feature is the single shaft configuration, which means only one motor drives both the separator sub-assy and the fan, which is unusual for this class of separator. This paper will describe all the reasons for this selection, the features of the system, the performances and the results obtained at the present stage of development.
Technical Paper

Integrated CO2 and Humidity Control by Membrane Gas Absorption

1997-07-14
972560
In a harmonized ESA/NIVR project the performance of membrane gas absorption for the simultaneous removal of carbon dioxide and moisture has been determined experimentally at carbon dioxide and humidity concentration levels representative for spacecraft conditions. Performance data at several experimental conditions have been collected. Removal of moisture can be controlled by the temperature of the absorption liquid. Removal of carbon dioxide is slightly affected by the temperature of the absorption liquid. Based on these measurements a conceptual design for a carbon dioxide and humidity control system for the Crew Transport Vehicle (CTV) is made. For the regeneration step in this design a number of assumptions have been made. The multifunctionality of membrane gas absorption makes it possible to combine a number of functions in one compact system.
Technical Paper

Mode Transition Analyses of the Attached Pressurized Module Cabin Air Loop with EcosimPro

2000-07-10
2000-01-2366
The change in mode status of the Attached Pressurized Module (APM), termed a mode transition, is due to the need of changing the APM configuration triggered by nominal or contingency events, i.e: initial system activation and further de/reactivation, payload activation, crew, ground or station initiated mode changes, etc. Past simulations of the APM Cabin Air Loop, for individual operational modes, have been performed by Dornier. This paper presents the results of the hydraulic and thermal analyses of the APM Cabin Air Loop for mode transition with the new version of the European Space Agency (ESA) supported software EcosimPro. The range of analysis has now been extended to long duration simulation of transitions between modes, which was impractical in the past.