Refine Your Search

Topic

Author

Search Results

Standard

"Startle Effect" and Crew Performance

2019-05-24
WIP
ARP7218
The scope of this ARP, "Startle Effect" and Crew Performance, includes pilots of turbine powered transport category aircraft and may also pertain to general aviation, the military, and/or other sectors of aircraft operations. It is focused on flight crews certified by the United States, however, may also pertain to crews certified by other countries. The scope describes all phases of training (initial, recurrent, upgrade, remedial, and operational) in both domestic and international flight operations, with the intent of assisting flight crews in responding to "startle effect".
Standard

10 Megabit/sec Network Configuration Digital Time Division Command/Response Multiplex Data Bus

2013-04-29
HISTORICAL
AS5652
This SAE Aerospace Standard (AS) contains requirements for a digital time division command/response multiplex data bus, for use in systems integration that is functionally similar to MIL-STD-1553B with Notice 2 but with a star topology and some deleted functionality. Even with the use of this document, differences may exist between multiplex data buses in different system applications due to particular application requirements and the options allowed in this document. The system designer must recognize this fact and design the multiplex bus controller (BC) hardware and software to accommodate such differences. These designer selected options must exist to allow the necessary flexibility in the design of specific multiplex systems in order to provide for the control mechanism, architectural redundancy, degradation concept, and traffic patterns peculiar to the specific application requirements.
Standard

10 Megabit/sec Network Configuration Digital Time Division Command/Response Multiplex Data Bus

2018-01-18
CURRENT
AS5652A
This SAE Aerospace Standard (AS) contains requirements for a digital time division command/response multiplex data bus, for use in systems integration that is functionally similar to MIL-STD-1553B with Notice 2 but with a star topology and some deleted functionality. Even with the use of this document, differences may exist between multiplex data buses in different system applications due to particular application requirements and the options allowed in this document. The system designer must recognize this fact and design the multiplex bus controller (BC) hardware and software to accommodate such differences. These designer selected options must exist to allow the necessary flexibility in the design of specific multiplex systems in order to provide for the control mechanism, architectural redundancy, degradation concept, and traffic patterns peculiar to the specific application requirements.
Standard

2-D CAD Template for SAE J826 H-point Machine

2022-02-18
CURRENT
J826/2_202202
This document describes the 2-D computer-aided design (CAD) template for the HPM-1 H-point machine or HPD available from SAE. The elements of the HPD include the curve shapes, datum points and lines, and calibration references. The intended purpose for this information is to provide a master CAD reference for design and benchmarking. The content and format of the data files that are available are also described.
Standard

2-D CAD Template for SAE J826 H-point Machine

2016-10-13
HISTORICAL
J826/2_201610
This document describes the 2-D computer-aided design (CAD) template for the HPM-1 H-point machine or HPD available from SAE. The elements of the HPD include the curve shapes, datum points and lines, and calibration references. The intended purpose for this information is to provide a master CAD reference for design and benchmarking. The content and format of the data files that are available are also described.
Standard

3D CAD for SAE J826 H-Point Machine

2021-11-16
CURRENT
J826/3_202111
This document describes the 3D computer-aided design (CAD) parts and file formats for the HPM-1 H-point machine available from SAE. The intended purpose for this information is to provide a master CAD reference for design and benchmarking.
Standard

60 V and 600 V Single Core Cables

2001-03-07
HISTORICAL
J2183_200103
This SAE Standard specifies the test methods, dimensions, and requirements for single core 60 V cables intended for use in road vehicle applications where the nominal system voltage ≤60 V DC (25 V AC). It also specifies additional test methods and/or requirements for 600 V cables intended for use in road vehicle applications where the nominal system voltage is >60 V DC (25 V AC) to ≤600 V DC (600 V AC). Where practical, this standard uses ISO 6722 for test methods, dimensions, and requirements. This standard covers ISO conductor sizes which usually differ from SAE conductor sizes. It also covers the individual cores in multicore cables. See ISO 6722 for “Temperature Class Ratings”.
Standard

60 V and 600 V Single-Core Cables

2006-04-25
HISTORICAL
J2183_200604
This Standard specifies the test methods, dimensions, and requirements for single-core 60 V cables intended for use in road vehicle applications where the nominal system voltage ≤ 60 V DC (25 V AC). It also specifies additional test methods and/or requirements for 600 V cables intended for use in road vehicle applications where the nominal system voltage is > 60 V DC (25 V AC) to ≤ 600 V DC (600 V AC). Where practical, this standard uses ISO 6722 for test methods, dimensions, and requirements. This standard covers ISO conductor sizes which usually differ from SAE conductor sizes. It also covers the individual cores in multi-core cables. See ISO 6722 for “Temperature Class Ratings”.
Standard

60 V and 600 V Single-Core Cables

2012-09-07
CURRENT
J2183_201209
This Standard specifies the test methods, dimensions, and requirements for single-core 60 V cables intended for use in road vehicle applications where the nominal system voltage ≤ 60 V DC (25 V AC). It also specifies additional test methods and/or requirements for 600 V cables intended for use in road vehicle applications where the nominal system voltage is > 60 V DC (25 V AC) to ≤ 600 V DC (600 V AC). Where practical, this standard uses ISO 6722 for test methods, dimensions, and requirements. This standard covers ISO conductor sizes which usually differ from SAE conductor sizes. It also covers the individual cores in multi-core cables. See ISO 6722 for “Temperature Class Ratings”.
Standard

A GUIDE TO THE DEVELOPMENT OF A GROUND STATION FOR ENGINE CONDITION MONITORING

1994-02-01
HISTORICAL
AIR4175
An effective ground station is vital to the successful implementation of an EMS and is a fundamental part of the total monitoring system design. Unlike on-board processing systems which principally use data to indicate when engine maintenance is required, ground stations offer much greater processing power to analyse and manipulate EMS data more comprehensively for both maintenance and logistics purposes. This document reviews the main EMS functions and discusses the operating requirements which will determine the basic design of a ground station, including the interfaces with other maintenance or logistics systems. A brief discussion is also included on some of the more recent advances in EMS ground station technology which have been specifically developed to provide more effective diagnostic capabilities for gas turbine engines. Finally, this document addresses the program management requirements associated with the initial development and on-going support of a ground station.
Standard

A Graphical Model for Interactive Distributed Control

2007-07-19
CURRENT
J2356_200707
The demonstrated architectural model and associated graphical techniques defined herein were developed to provide a simple method of visualizing the general functional operation or behavior of a Distributed Embedded System with a strong emphasis on representing system time characteristics.
Standard

A Guide for the Selection of Quick-Disconnect Couplings for Aerospace Fluid Systems

2013-01-02
HISTORICAL
AIR1047D
The factors involved in the selection of a quick-disconnect are grouped into the following classifications for the purpose of discussion: a Functional considerations. b Weight considerations. c Environmental performance factors. d End fitting types. e Additional considerations. A quick-disconnect coupling as used in this AIR is one that can be rapidly and repetitively connected and disconnected without excessive fluid loss. The relative importance of the design factors depends upon the fluid medium of the particular system in which quick-disconnect is to be used. The effect of the fluid media on each factor is discussed in this report where applicable.
Standard

A TEST FOR EVALUATING THE REARWARD AMPLIFICIATION OF MULTI-ARTICULATED VEHICLES

1993-09-01
HISTORICAL
J2179_199309
The procedure applies to heavy vehicles weighing more than 11 800 kg (26 000 lb) and particularly to those vehicles having two or more articulation joints that allow rotation in a horizontal plane. The procedure pertains to the lateral directional response of multi-articulated vehicles in avoidance maneuvers performed at highway speeds without braking.
Standard

A Tilt Table Procedure for Measuring the Static Rollover Threshold for Heavy Trucks

1998-12-01
HISTORICAL
J2180_199812
The test procedure applies to roll coupled units such as straight trucks, tractor semitrailers, full trailers, B-trains, etc. The test is aimed at evaluating the level of lateral acceleration required to rollover a vehicle or a roll-coupled unit of a vehicle in a steady turning situation. Transient, vibratory, or dynamic rollover situations are not simulated by this test. Furthermore, the accuracy of the test decreases as the tilt angle increases, although this is a small effect at the levels of tilt angle used in testing heavy trucks. The test accuracy is accepted for vehicles that will rollover at lateral acceleration levels below 0.5 g corresponding to a tilt table angle of less than approximately 27 degrees. Even so, the results for heavy trucks with rollover thresholds greater than 0.5 g could be used for comparing their relative static roll stability.
X