Refine Your Search

Search Results

Viewing 1 to 5 of 5
Technical Paper

A Portable Unit to Measure Metabolic Rate during Shirtsleeve and Suited EVA Tests

2008-06-29
2008-01-2110
This paper presents a new portable metabolic device (PUMA-Portable Unit for Metabolic Analysis) developed at the NASA Glenn Research Center. PUMA is a battery-operated, wearable unit to measure metabolic rate (minute ventilation, oxygen up-take, carbon dioxide output and heart rate) in a clinical setting, in the field or in remote, extreme environments. The critical sensors in PUMA are located close to the mouth and sampled at 10 Hz to allow intra-breath measurements. PUMA transmits metabolic data wirelessly to a remote computer for data analysis and storage. In addition to it's primary function as a portable metabolic measurement device, the PUMA sensors can also be easily adapted to other applications, including future EVA suits where they could measure metabolic rate for a suited crew member. The first section of the paper discusses the specific technologies and innovations of PUMA.
Technical Paper

Diffusion Limited Supercritical Water Oxidation (SCWO) in Microgravity Environments

2006-07-17
2006-01-2132
Tests designed to quantify the gravitational effects on thermal mixing and reactant injection in a Supercritical Water Oxidation (SCWO) reactor have recently been performed in the Zero Gravity Facility (ZGF) at NASA's Glenn Research Center. An artificial waste stream, comprising aqueous mixtures of methanol, was pressurized to approximately 250 atm and then heated to 450°C. After uniform temperatures in the reactor were verified, a controlled injection of air was initiated through a specially designed injector to simulate diffusion limited reactions typical in most continuous flow reactors. Results from a thermal mapping of the reaction zone in both 1-g and 0-g environments are compared. Additionally, results of a numerical model of the test configuration are presented to illustrate first order effects on reactant mixing and thermal transport in the absence of gravity.
Technical Paper

Fire Suppression Technology in Human-Crewed Spacecraft -A Trade Study

2007-07-09
2007-01-3256
This paper discusses the current state of technology in reduced gravity fire suppression. The focus is on the unique issues associated with the CEV and future spacecraft including operation in reduced gravity and enriched oxygen ambients. Inert gas agents such as carbon dioxide, nitrogen and helium have different minimum extinguishing concentrations (MEC) in microgravity compared to normal gravity; in most instances the MEC in microgravity being higher than in normal gravity. This means that designs based on terrestrial standards will not offer the same factor of safety in microgravity. The results also show that the MEC is a strong function of ambient oxygen concentration in reduced gravity (as expected).
Journal Article

Measurement of Smoke Particle Size under Low-Gravity Conditions

2008-06-29
2008-01-2089
Smoke detection experiments were conducted in the Microgravity Science Glovebox (MSG) on the International Space Station (ISS) during Expedition 15 in an experiment entitled Smoke Aerosol Measurement Experiment (SAME). The preliminary results from these experiments are presented. In order to simulate detection of a prefire overheated-material event, samples of five different materials were heated to temperatures below the ignition point. The smoke generation conditions were controlled to provide repeatable sample surface temperatures and air flow conditions. The smoke properties were measured using particulate aerosol diagnostics that measure different moments of the size distribution. These statistics were combined to determine the count mean diameter which can be used to describe the overall smoke distribution.
Technical Paper

Smoke Particle Sizes in Low-Gravity and Implications for Spacecraft Smoke Detector Design

2009-07-12
2009-01-2468
This paper presents results from a smoke detection experiment entitled Smoke Aerosol Measurement Experiment (SAME) which was conducted in the Microgravity Science Glovebox on the International Space Station (ISS) during Expedition 15. Five different materials representative of those found in spacecraft were pyrolyzed at temperatures below the ignition point with conditions controlled to provide repeatable sample surface temperatures and air flow conditions. The sample materials were Teflon®, Kapton®, cellulose, silicone rubber and dibutylphthalate. The transport time from the smoke source to the detector was simulated by holding the smoke in an aging chamber for times ranging from 10 to1800 seconds. Smoke particle samples were collected on Transmission Electron Microscope (TEM) grids for post-flight analysis.