Refine Your Search

Topic

Author

Search Results

Standard

(R) Dedicated Short Range Communications (DSRC) Message Set Dictionary

2009-11-19
HISTORICAL
J2735_200911
This SAE Standard specifies a message set, and its data frames and data elements specifically for use by applications intended to utilize the 5.9 GHz Dedicated Short Range Communications for Wireless Access in Vehicular Environments (DSRC/WAVE, referenced in this document simply as “DSRC”), communications systems. Although the scope of this Standard is focused on DSRC, this message set, and its data frames and data elements have been designed, to the extent possible, to also be of potential use for applications that may be deployed in conjunction with other wireless communications technologies. This Standard therefore specifies the definitive message structure and provides sufficient background information to allow readers to properly interpret the message definitions from the point of view of an application developer implementing the messages according to the DSRC Standards.
Standard

280 RELAY FOOTPRINT

1994-06-01
CURRENT
J1744_199406
This SAE Standard covers a terminal footprint for mini and micro relays used in surface vehicle electrical systems.
Standard

60 V and 600 V Single Core Cables

2001-03-07
HISTORICAL
J2183_200103
This SAE Standard specifies the test methods, dimensions, and requirements for single core 60 V cables intended for use in road vehicle applications where the nominal system voltage ≤60 V DC (25 V AC). It also specifies additional test methods and/or requirements for 600 V cables intended for use in road vehicle applications where the nominal system voltage is >60 V DC (25 V AC) to ≤600 V DC (600 V AC). Where practical, this standard uses ISO 6722 for test methods, dimensions, and requirements. This standard covers ISO conductor sizes which usually differ from SAE conductor sizes. It also covers the individual cores in multicore cables. See ISO 6722 for “Temperature Class Ratings”.
Standard

60 V and 600 V Single-Core Cables

2006-04-25
HISTORICAL
J2183_200604
This Standard specifies the test methods, dimensions, and requirements for single-core 60 V cables intended for use in road vehicle applications where the nominal system voltage ≤ 60 V DC (25 V AC). It also specifies additional test methods and/or requirements for 600 V cables intended for use in road vehicle applications where the nominal system voltage is > 60 V DC (25 V AC) to ≤ 600 V DC (600 V AC). Where practical, this standard uses ISO 6722 for test methods, dimensions, and requirements. This standard covers ISO conductor sizes which usually differ from SAE conductor sizes. It also covers the individual cores in multi-core cables. See ISO 6722 for “Temperature Class Ratings”.
Standard

A/C Compressor Oil Separator Effectiveness Test Standard

2019-07-15
CURRENT
J3112_201907
This SAE Standard establishes the test conditions and reporting method for quantifying refrigerant circuit oil circulation rate (OCR) reduction effectiveness of mobile air conditioning compressors using R-134a and R-1234yf refrigerants that include oil separators and/or other design features for the purpose of reducing the OCR in the refrigerant circuit. This standard and the OCR values it produces are not intended to make judgement on suitability of OCR values with regard to compressor durability.
Standard

A/C Compressor Oil Separator Effectiveness Test Standard

2017-03-07
HISTORICAL
J3112_201703
This SAE Standard establishes the test conditions and reporting method for quantifying refrigerant circuit oil circulation rate (OCR) reduction effectiveness of mobile air conditioning compressors using R-134a and R-1234yf refrigerants that include oil separators and/or other design features for the purpose of reducing the OCR in the refrigerant circuit.
Standard

ACCELERATED EXPOSURE OF AUTOMOTIVE INTERIOR TIRM COMPONENTS USING A CONTROLLED IRRADIANCE WATER COOLED XENON-ARC APPARATUS

1992-03-01
HISTORICAL
J1885_199203
This test method specifies the operating procedures for a controlled irradiance, water cooled xenon-arc apparatus used for the accelerated exposure of various automotive interior trim components. Test durations, as well as any exceptions to the sample preparation and performance evaluation procedures contained in this document, are covered in material specifications of the different automotive manufacturers.
Standard

ACCOMMODATION TOOL REFERENCE POINT

1985-10-01
HISTORICAL
J1516_198510
Reference lines have been developed to which driver workspace accomodation tools can be located in vehicle space. The lines describe horizontal reference point locations as a function of vehicle H-point height (H30). One reference line has been established for use in vehicles with H-point heights (H 30) and steering wheel diameters (W9) less than 405mm and 450mm, respectively. (Class A Vehicles) This point can be used to reference appropriate workspace tools to accommodate a driver population with a male to female ratio of one to one. Separate reference lines have been established for use in vehicles with H-point heights (H30) between 405 and 530mm and steering wheel diameters (W9) between 450 and 560mm with treadle type pedals. (Class B Vehicles) See Fig. 1. Three lines are available for use in Class B vehicles depending on the percentages of males and females in the population the designer wishes to accommodate.
Standard

ACOUSTICAL AND THERMAL MATERIALS TEST PROCEDURE

1989-10-01
HISTORICAL
J1324_198910
This SAE Recommended Practice provides test methods for determining the characteristics of acoustical and thermal materials. Where applicable, methods of test developed by SAE and ASTM have been referenced.