Refine Your Search

Topic

Search Results

Standard

DIMENSIONAL AND PERFORMANCE SPECIFICATION FOR AFTER-MARKET GASOLINE ENGINE OIL FILTERS

2021-05-13
CURRENT
USCAR36-1
This specification defines the dimensional and performance requirements for aftermarket spin-on oil filters intended for use on gasoline engines. Filters meeting this specification may also be suitable for use on some diesel applications. Filters meeting these dimensional limits are intended to meet the oil filter fit and package requirements for engine and vehicle designs. Filters meeting the performance requirements are intended to maintain sufficient durability to support typical 10000 mile oil change intervals. Some OEM engines may require special filters for which this specification would not support. Filters that meet or exceed this specification requirements for both dimensional and performance can claim “Conformance to SAE/USCAR - 36 Specifications.” Filters that meet just the performance specifications (ie. may have different thread) can claim “Aligns to SAE/USCAR - 36 Performance Specifications.”
Standard

Dimensional and Performance Specification for After-Market Gasoline Engine Oil Filters

2013-01-30
HISTORICAL
USCAR36
This specification defines the dimensional and performance requirements for aftermarket spin-on oil filters intended for use on gasoline engines. Filters meeting this specification may also be suitable for use on some diesel applications. Filters meeting these dimensional limits are intended to meet the oil filter fit and package requirements for engine and vehicle designs. Filters meeting the performance requirements are intended to maintain sufficient durability to support many of the OEM's recommended oil change intervals. Some OEM engines may require special filters for which this specification would not support.
Standard

ELECTRICAL CONNECTOR ASSEMBLY ERGONOMIC DESIGN CRITERIA

2003-05-03
HISTORICAL
USCAR25
This document describes the design and assembly force guidelines for conventional and mechanical assist (lever and slide-lock) electrical connectors and CPA’s. All possible designs and applications cannot be anticipated in creating these guidelines. Where there are questions of adherence to this document, such as use of an “off-the-shelf” design, always consult the responsible Ergonomics department. Refer to SAE/USCAR-12 Wiring Component Design Guidelines for additional guidelines.
Standard

ELECTRICAL CONNECTOR ASSEMBLY ERGONOMIC DESIGN CRITERIA

2008-09-26
HISTORICAL
USCAR25-1
This document describes the design, assembly force, and packaging guidelines for conventional hand-plug, mechanical assist and twist lock electrical connectors, as well as Connector Position Assurances (CPAs). All possible designs and applications could not be anticipated in creating these guidelines. Where there are questions of adherence to this document, such as use of an “off-the-shelf” design, always consult the responsible Ergonomics Department. Refer to SAE/USCAR-12 Wiring Component Design Guidelines for additional guidelines.
Standard

ELECTRICAL CONNECTOR DESIGN CRITERIA

2016-02-12
HISTORICAL
USCAR12-4
This document gives specific and measurable design criteria to be applied at a design review prior to tooling. The specification is formatted as a checklist to aid in its use. The requirements do not apply in all situations so engineering judgment must be used. This is a specification for design criteria; applicable performance specifications (USCAR-2, etc.) must still be performed. Items in this document are grouped by component as follows: A Terminals B Secondary Terminal Locks C Connectors D Connector Locks E Secondary Connector Locks (Connector Position Assurance, CPA) F Connector Seals G Serviceability H High Voltage (≥60V) Application Requirements I Drawing and General Requirements
Standard

ELECTRICAL CONNECTOR DESIGN CRITERIA

2017-08-17
HISTORICAL
USCAR12-5
This document gives specific and measurable design criteria to be applied at a design review prior to tooling. The specification is formatted as a checklist to aid in its use. The requirements do not apply in all situations so engineering judgment must be used. This is a specification for design criteria; applicable performance specifications (USCAR-2, etc.) must still be performed. Items in this document are grouped by component as follows: A Terminals B Secondary Terminal Locks C Connectors D Connector Locks E Secondary Connector Locks (Connector Position Assurance, CPA) F Connector Seals G Serviceability H High Voltage (≥60V) Application Requirements I Drawing and General Requirements
Standard

ELECTRICAL CONNECTOR DESIGN REQUIREMENTS

2021-01-20
CURRENT
USCAR12-6
This document gives specific and measurable design requirements to be applied at a design review prior to tooling. The specification is formatted as a checklist to aid in its use. The requirements do not apply in all situations so engineering judgment must be used. This is a specification for design; applicable performance specifications (USCAR-2, etc.) must still be performed. Specific requirements in this document are grouped by component using a prefix as shown in Table 1 and are numbered by an item number following the prefix.
Standard

ENGINE OIL PUMP PERFORMANCE AND DURABILITY TEST PROCEDURES

2023-03-23
CURRENT
USCAR46
SAE/USCAR-46 defines test methods and outputs for engine oil pump bench testing. Performance and durability testing are the primary focus of this standard. This is written to specifically address testing of electronically controlled variable displacement pumps but can be adapted to mechanically controlled pumps and other pump technologies as needed. This standard outlines critical inputs and outputs in order to perform the testing and report results, but does not specifically set the acceptance standards or pass/fail criteria. Acceptance criteria must be set by the customer.
Standard

Ergonomics Specification for Electrical Connections

2016-02-15
HISTORICAL
USCAR25-2
This document describes the design relative to assembly force, and hand clearance guidelines for conventional hand-plug, mechanical assist and twist lock electrical connectors, as well as Connector Position Assurances (CPAs). The minimum values associated with this design guide need to be evaluated against other critical characteristics that impact quality, efficiency and other traits of assembly feasibility. All possible designs and applications could not be anticipated in creating these guidelines. Where there are questions of adherence to this document, such as use of an “off-the-shelf” design, always consult the responsible Ergonomics Department.
Standard

Ergonomics Specification for Electrical Connections

2016-03-10
CURRENT
USCAR25-3
This document describes the design relative to assembly force, and hand clearance guidelines for conventional hand-plug, mechanical assist and twist lock electrical connectors, as well as Connector Position Assurances (CPAs). The minimum values associated with this design guide need to be evaluated against other critical characteristics that impact quality, efficiency and other traits of assembly feasibility. All possible designs and applications could not be anticipated in creating these guidelines. Where there are questions of adherence to this document, such as use of an “off-the-shelf” design, always consult the responsible Ergonomics Department.
Standard

GRAIN FLOW PATTERN FOR BOLTS, SCREWS, AND STUDS

2019-03-14
CURRENT
USCAR8-4
This specification covers the grain flow pattern requirements in headed bolts, screws, and studs. The heading practice in the manufacture of the bolt, screw, or stud sets the grain flow pattern, but it is also greatly influenced by the fastener and tooling design as well as cold-forging setup. The use of tooling design simulation software is recommended and a commonly used practice that provides reliable forging predictions for superior grain flow quality.
Standard

LEAD-FREE SOLDER VALIDATION TEST PLAN

2020-11-19
CURRENT
USCAR40-2
This guideline is applicable to existing lead solder production products that will change to lead-free solder processes to meet the ELV Directive 2000/53/EC Annex II, exemption 8B requirements. This guideline is applicable to similar products used by multiple OEM's that have the same manufacturing processes / equipment. The intent is to streamline the supplier’s environmental testing via common qualification to reduce timing, quantities, and costs.
Standard

LEAD-FREE SOLDER VALIDATION TEST PLAN

2011-04-01
HISTORICAL
USCAR40
This guideline is applicable to existing lead solder production products that will change to lead-free solder processes to meet the ELV Directive 2000/53/EC Annex II, exemption 8B requirements. This guideline is applicable to similar products used by multiple OEM's that have the same manufacturing processes / equipment. The intent is to streamline the supplier’s environmental testing via common qualification to reduce timing, quantities, and costs.
Standard

Lead-Free Solder Validation Test Plan

2015-04-22
HISTORICAL
USCAR40-1
This guideline is applicable to existing lead solder production products that will change to lead-free solder processes to meet the ELV Directive 2000/53/EC Annex II, exemption 8B requirements. This guideline is applicable to similar products used by multiple OEM's that have the same manufacturing processes / equipment. The intent is to streamline the supplier’s environmental testing via common qualification to reduce timing, quantities, and costs.
Standard

PERFORMANCE SPECIFICATION FOR AUTOMOTIVE ELECTRICAL CONNECTOR SYSTEMS

2004-05-25
HISTORICAL
USCAR2-4
Procedures included within this specification are intended to cover performance testing at all phases of development, production, and field analysis of electrical terminals, connectors, and components that constitute the electrical connection systems in low voltage (0 - 20 VDC) road vehicle applications. These procedures are only applicable to terminals used for In-Line, Header, and Device Connector systems with and without Shorting Bars. They are not applicable to Edge Board connector systems, > 20 VAC or DC, or to eyelet type terminals.
Standard

PERFORMANCE SPECIFICATION FOR AUTOMOTIVE ELECTRICAL CONNECTOR SYSTEMS

2007-10-08
HISTORICAL
USCAR2-5
Procedures included within this specification are intended to cover performance testing at all phases of development, production, and field analysis of electrical terminals, connectors, and components that constitute the electrical connection systems in low voltage (0 - 20 VDC) road vehicle applications. These procedures are only applicable to terminals used for In-Line, Header, and Device Connector systems with and without Shorting Bars. They are not applicable to Edge Board connector systems, twist lock connector systems, > 20 VAC or DC, or to eyelet type terminals.
Standard

PERFORMANCE SPECIFICATION FOR AUTOMOTIVE ELECTRICAL CONNECTOR SYSTEMS

2022-06-30
CURRENT
USCAR2-8
This specification covers performance testing at all phases of development, production, and field analysis of electrical terminals, connectors, and components that constitute the electrical connection systems in road vehicle applications that are: low voltage (0 to 20 VDC) or Coaxial. Incomplete (mechanical) specifications for jacketed twisted pair connectors are also provided. These procedures are only applicable to terminals used for In-Line, Header, and Device Connector systems. They are not applicable to Edge Board connector systems, twist-lock connector systems, >20 VAC or DC, or to eyelet terminals. No electrical connector, terminal, or related component may be represented as having met USCAR specifications unless conformance to all applicable requirements of this specification have been verified and documented. All required verification and documentation must be done by the supplier of the part or parts.
Standard

PERFORMANCE SPECIFICATION FOR AUTOMOTIVE RF CONNECTOR SYSTEMS

2023-07-10
CURRENT
USCAR17-6
This document contains procedures for testing performance of SMB-style electrical terminals, connectors and components for coaxial cable connection systems intended for road vehicle applications. These are often called FAKRA II designs. This specification does not apply to the Non RF portion of a Hybrid RF connection system. The intent of this specification is to qualify sealed and unsealed RF connectors that operate at frequencies from DC to 6 GHz. The characteristic impedance of the SMB/FAKRA connection system is 50 ohms however this specification does not exclude the use of these RF connectors on non-50 ohm cables or systems. This specification does not apply to single conductor wire or twisted pair connection systems. This specification (along with SAE/USCAR 18) is designed to provide the mechanical and electrical data required to insure that assemblies from various manufacturers will perform reliably in actual conditions.
X