Refine Your Search

Topic

Search Results

Standard

AEROSPACE INFORMATION REPORT FOR CONTINUOUS FLOW OXYGEN HOSE DISCONNECT FITTINGS

1991-09-01
HISTORICAL
AIR1358
This AIR indicates those dimensions, deemed critical by the manufacturer, which are required to be adhered to so that proper mating of the disconnect hose fitting with the correct disconnect be accomplished. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
Standard

Aerospace Information Report for Continuous Flow Oxygen Hose Disconnect Fittings

2009-08-27
HISTORICAL
AIR1358B
This Aerospace Information Report (AIR) indicates those dimensions, deemed critical by the manufacturer to assure proper mating of disconnect hose fittings. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
Standard

Aerospace Information Report for Continuous Flow Oxygen Hose Disconnect Fittings

2000-10-01
HISTORICAL
AIR1358A
This AIR indicates those dimensions, deemed critical by the manufacturer, which are required to be adhered to so that proper mating of the disconnect hose fitting with the correct disconnect be accomplished. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
Standard

Aerospace Information Report for Continuous Flow Oxygen Hose Disconnect Fittings

2014-12-31
CURRENT
AIR1358C
This Aerospace Information Report (AIR) indicates those dimensions, deemed critical by the manufacturer to assure proper mating of disconnect hose fittings. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
Standard

Aircraft Oxygen Replenishment Coupling for Civil Transport Aircraft (Design Standard)

2021-03-09
WIP
AS1219B
This SAE Aerospace Design Standard defines a coupling, which is installed in a high pressure (1850 to 2000 psig) oxygen system of a civil transport aircraft for the purpose of mating to ground oxygen replenishment facilities. Dimensions developed from AND10089, Detail Specification Sheet for Fitting End, Design Standard, For Cone Connection.
Standard

Aircraft Oxygen Replenishment Coupling for Civil Transport Aircraft (Design Standard)

2020-02-28
CURRENT
AS1219A
This SAE Aerospace Design Standard defines a coupling, which is installed in a high pressure (1850 to 2000 psig) oxygen system of a civil transport aircraft for the purpose of mating to ground oxygen replenishment facilities. Dimensions developed from AND10089, Detail Specification Sheet for Fitting End, Design Standard, For Cone Connection.
Standard

Aviator's Breathing Oxygen Purity Standard

2023-08-23
CURRENT
AS8010D
This document defines the minimum degree of purity and maximum levels of certain deleterious impurities allowable for aviator's breathing oxygen at the point of manufacture or generation. It covers gaseous, liquid, and chemically generated oxygen, and oxygen supplied by in situ concentration and in situ electrolysis. Different limits are established for oxygen from different sources, in recognition of differences in the ways the oxygen is stored, dispensed, and utilized, taking into account the safety of the user. These limits are not intended to specifically reflect upon the relative capabilities or merits of various technologies. Procurement documents may specify more stringent limits, where required for specific applications. Medical oxygen is not covered by this standard. In the United States, medical oxygen is a prescription drug and complies with the United States Pharmacopoeia (USP).
Standard

Continuous Flow Oxygen Regulator

2018-10-18
HISTORICAL
AS1197A
This standard covers regulators of the following types: Type I - Automatic Continuous Flow Type II - Adjustable Continuous Flow Type III - Pre-set Continuous Flow Class A - Cylinder Mounted Class B - Line Mounted Special - Composite Continuous Flow (Appendix)
Standard

Crewmember Demand Oxygen Mask For Transport Category Aircraft

2016-06-09
HISTORICAL
AS8026A
This standard covers oxygen masks and breathing valves used with both panel mounted and mask mounted demand and pressure-demand oxygen regulators. Mask mounted oxygen regulators are covered under other standards, but when the mask mounted regulator incorporates an integral exhalation valve, the performance of this valve shall meet the requirements of this standard.
Standard

Crewmember Demand Oxygen Mask for Transport Category Aircraft

2019-08-14
CURRENT
AS8026B
This standard covers oxygen masks and breathing valves used with both panel mounted and mask mounted demand and pressure-demand oxygen regulators. Mask mounted oxygen regulators are covered under other standards, but when the mask mounted regulator incorporates an integral exhalation valve, the performance of this valve shall meet the requirements of this standard.
Standard

DYNAMIC TESTING SYSTEM FOR OXYGEN BREATHING EQUIPMENT

1969-04-01
HISTORICAL
ARP1109
This ARP covers a system and method to be used, at all appropriate altitudes, in testing of breathing oxygen systems consisting of demand regulator, connecting hose, and mask, or regulator and helmet systems, or individual components.
Standard

HIGH PRESSURE OXYGEN SYSTEM FILLER VALVE

1971-07-30
HISTORICAL
AS1225
This AS covers oxygen filler valves for use in aircraft to ensure safe servicing of high pressure oxygen system cylinders. The intent is that the valve shall automatically control the rate of fill such that the temperature rise in the oxygen system caused by compression heating of the gas will be within acceptable limits. In addition, the valve shall have a pressure sensitive closing valve to automatically control the final pressure for a correct amount of oxygen in the system cylinder. The pressure closing level may be manually selected by means of adjustment dials on the valve.
Standard

MINIMUM STANDARD FOR OXYGEN PRESSURE REDUCERS

1991-09-01
HISTORICAL
AS1248
This standard is designed to cover all types of pressure reducers required for oxygen systems and for all performance profiles without regard for a particular inlet pressure or outlet pressure performance curve. Special attention will be given, however, to construction requirements essential in reducers where critical high initial oxygen pressures such as 1850 to 2250 psig (12.76 to 15.51 MN/m2 gauge) at 70° F (21.1° C) are involved.
Standard

MINIMUM STANDARD FOR PORTABLE GASEOUS, OXYGEN EQUIPMENT

1976-02-01
HISTORICAL
AS1046A
This standard is intended to apply to that portable compressed gaseous oxygen equipment used for the administration of supplementary and/or first aid oxygen to one or more occupants of either private or commercial transport aircraft.