AUTOMOTIVE REFRIGERANT RECOVERY/RECYCLING EQUIPMENT INTENDED FOR USE WITH BOTH R12 AND R134A

1995-10-01
J1770_199510
The purpose of this SAE Standard is to establish the specific minimum equipment requirements for recovery/recycling equipment intended for use with both R12 and R134a in a common refrigerant circuit that has been directly removed from, and is intended for reuse in, mobile air-conditioning (A/C) systems. This document does not apply to equipment used for R12 and R134a having a common enclosure with separate circuits for each refrigerant.
Standard

Automotive Refrigerant Recovery/Recycling Equipment Intended for Use With Both R12 and R134a

2010-11-05
J1770_201011
The purpose of this SAE Standard is to establish the specific minimum equipment requirements for recovery/recycling equipment intended for use with both R12 and R134a in a common refrigerant circuit that has been directly removed from, and is intended for reuse in, mobile air-conditioning (A/C) systems. This document does not apply to equipment used for R12 and R134a having a common enclosure with separate circuits for each refrigerant.
Standard

Automotive Refrigerant Recovery/Recycling/Recharging Equipment Intended for use with Both R-1234yf and R-134a

2020-11-13
J3030_202011
The purpose of this SAE Standard is to establish the specific minimum equipment requirements for recovery/recycling/recharge equipment intended for use with both R-1234yf and R-134a in a common refrigerant circuit that has been directly removed from, and is intended for reuse in, mobile air-conditioning (A/C) systems. This document does not apply to equipment used for R-1234yf and R-134a having a common enclosure with separate circuits for each refrigerant, although some amount of separate circuitry for each refrigerant could be used.
Standard

Automotive Refrigerant Recovery/Recycling/Recharging Equipment Intended for use with Both R-1234yf and R-134a

2015-07-08
J3030_201507
The purpose of this SAE Standard is to establish the specific minimum equipment requirements for recovery/recycling/recharge equipment intended for use with both R-1234yf and R-134a in a common refrigerant circuit that has been directly removed from, and is intended for reuse in, mobile air-conditioning (A/C) systems. This document does not apply to equipment used for R-1234yf and R-134a having a common enclosure with separate circuits for each refrigerant, although some amount of separate circuitry for each refrigerant could be used.
Standard

CFC-12 (R-12) Refrigerant Recovery Equipment for Mobile Automotive Air-Conditioning Systems

2011-08-12
J2209_201108
The purpose of this SAE Standard is to provide equipment specifications for CFC-12 (R-12) recovery for return to a refrigerant reclamation facility that will process it to the appropriate ARI Standard (Air Conditioning and Refrigerant Institute) or allow for recycling of the recovered refrigerant in equipment that is certified to meet the requirements of SAE J1991. Under the existing rule, the U.S. EPA requires refrigerant removed from a mobile air-conditioning (A/C) system using recovery equipment certified to meet SAE J2209 can only be recycled using equipment meeting SAE J1991 that is owned by the same company or individual. It is not acceptable that the refrigerant removed from a mobile A/C system, with this equipment, be directly returned to a mobile A/C system. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar CFC-12 (R-12) systems.
Standard

Criteria for Refrigerant Identification Equipment for Use with Mobile Air-Conditioning Systems

2011-05-26
J1771_201105
This SAE Standard applies to refrigerant identification equipment to be used for identifying refrigerant CFC-12 (R-12) and HFC-134a (R-134a) refrigerant when servicing a mobile A/C system or for identifying refrigerant in a container to be used to charge a mobile A/C system. Identification or other refrigerants are the option of the equipment manufacturer.
Standard

HFC-134a (R-134a) Recovery/Recycle/Recharging Equipment for Mobile Air-Conditioning Systems

2020-01-03
J2788_202001
The purpose of this SAE Standard is to establish the specific minimum equipment performance requirements for recovery and recycling of HFC-134a that has been directly removed from, and is intended for reuse in, mobile air-conditioning (A/C) systems. It also is intended to establish requirements for equipment used to recharge HFC-134a to an accuracy level that meets Section 9 of this document and SAE J2099. The requirements apply to the following types of service equipment and their specific applications. a Recovery/recycling equipment b Recovery/recycling-refrigerant charging c Refrigerant recharging equipment only
Standard

HFC-134a (R-134a) Recovery/Recycle/Recharging Equipment for Mobile Air-Conditioning Systems

2010-06-21
J2788_201006
The purpose of this SAE Standard is to establish the specific minimum equipment performance requirements for recovery and recycling of HFC-134a that has been directly removed from, and is intended for reuse in, mobile air-conditioning (A/C) systems. It also is intended to establish requirements for equipment used to recharge HFC-134a to an accuracy level that meets Section 9 of this document and SAE J2099. The requirements apply to the following types of service equipment and their specific applications. a Recovery/Recycling Equipment, b Recovery/Recycling-Refrigerant Charging, c Refrigerant Recharging Equipment Only.
Standard

HFC-134a (R-134a) Refrigerant Recovery Equipment for Mobile Automotive Air-Conditioning Systems

2011-11-21
J1732_201111
The purpose of this SAE Standard is to provide equipment specifications for the recovery of HFC-134a (R-134a) refrigerant to be returned to a refrigerant reclamation facility that will process it to the appropriate ARI 700 Standard or allow for recycling of the recovered refrigerant to SAE J2210 specifications by using Design Certified equipment of the same ownership. It is not acceptable that the refrigerant removed from a mobile air-conditioning (A/C) system, with this equipment be directly returned to a mobile A/C system. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar HFC-134a (R-134a) A/C systems.
Standard

HFC-134a RECYCLING EQUIPMENT FOR MOBILE AIR-CONDITIONING SYSTEMS

1991-12-01
J2210_199112
The purpose of this SAE Recommended Practice is to establish the specific minimum equipment requirements for recycling HFC-134a that has been directly removed from, and is intended for reuse in, mobile air-conditioning (A/C) systems.
Standard

HFC-134a Refrigerant Electronic Leak Detectors, Minimum Performance Criteria

2019-03-20
J2791_201903
This SAE Standard provides testing and functional requirements to meet specified minimum performance criteria for electronic probe-type leak detectors. So they will identify smaller refrigerant leaks when servicing all motor vehicle air conditioning systems, including those engineered with improved sealing and smaller refrigerant charges to address environmental concerns and increase system efficiency. This document does not address any safety issues concerning their design or use.
Standard

Method for Removal of Refrigerant from Mobile Air Conditioning System to Quantify Charge Amount

2017-03-10
J2762_201703
This Standard provides an overview of results and requirements needed to remove refrigerant from a mobile air conditioning system for determining refrigerant emissions (leakage). This reclaim procedure for use on fleet vehicles in a field service environment should produce an accuracy and repeatability sufficient to determine refrigerant loss within 2 g.
Standard

Method for Removal of Refrigerant from Mobile Air Conditioning System to Quantify Charge Amount

2011-02-04
J2762_201102
This Standard provides an overview of results and requirements needed to remove refrigerant from a mobile air conditioning system for determining refrigerant emissions (leakage). This reclaim procedure for use on fleet vehicles in a field service environment should produce an accuracy and repeatability sufficient to determine refrigerant loss within 2 g.
Standard

Minimum Performance Requirements for Non-Refrigerant Tracer Gases and Electronic Tracer Gas Leak Detectors

2023-05-01
J2970_202305
This SAE Standard provides the testing and functional requirements guidance necessary for a leak detection device that uses any non-A/C refrigerant tracer gas, such as helium or a nitrogen-hydrogen blend, to provide functional performance equivalent to a refrigerant electronic leak detector. It explains how a non-refrigerant leak detector’s calibration can be established to provide levels of detection equal to electronic leak detectors that meet SAE J2791 for R-134a and SAE J2913 for R-1234yf.
Standard

Minimum Performance Requirements for Non-Refrigerant Tracer Gasses and Electronic Tracer Gas Leak Detectors

2012-07-19
J2970_201207
This standard provides the testing and functional requirements guidance necessary for a leak detection device that uses any non-A/C refrigerant tracer gas, such as helium or a nitrogen-hydrogen blend, to provide functional performance equivalent to a refrigerant electronic leak detector. It explains how a non- refrigerant leak detector’s calibration can be established to provide levels of detection equal to electronic leak detectors that meet SAE J2791 for R-134a and SAE J2913 for R-1234yf.
Standard

Minimum Performance Requirements for Non-Refrigerant Tracer Gasses and Electronic Tracer Gas Leak Detectors

2015-03-17
J2970_201503
This standard provides the testing and functional requirements guidance necessary for a leak detection device that uses any non-A/C refrigerant tracer gas, such as helium or a nitrogen-hydrogen blend, to provide functional performance equivalent to a refrigerant electronic leak detector. It explains how a non- refrigerant leak detector’s calibration can be established to provide levels of detection equal to electronic leak detectors that meet SAE J2791 for R-134a and SAE J2913 for R-1234yf.