The scope and purpose of this SAE Recommended Practice is to provide a standard pattern or sequence for the manual control of automatic transmissions in passenger cars and light-duty trucks.
This test procedure is intended to apply to hydraulic pump suction filters and strainers used in automotive automatic transmissions that include hydraulic power pumps. The various paragraphs of Section 5, “Test Procedures,” include a variety of tests and alternative tests that are not applicable to all filters and applications, so the engineer must specify which tests are to be performed for a particular application. These test procedures are intended to evaluate filter functional performance characteristics only, durability is not evaluated under this standard. Filter design requirements must be specified by the engineer on the filter assembly drawing, an applicable engineering specification, or they may be summarized on an application data sheet similar to that found in this recommended practice. See Figure 6, “Filter Assembly Application and Data Sheet.” Pressure circuit filters, both barrier and system contamination control types, are not covered under this standard.
The scope and purpose of this SAE Recommended Practice is to provide a standard pattern or sequence for the manual control of automatic transmissions in passenger cars and light-duty trucks. This generally refers to left hand drive mechanical shift applications.
The following listed definitions are intended to establish terminology and criteria for describing the various kinds of automotive transmissions. A specific arrangement may be described by a combination of several of these definitions.
The purpose of this SAE Recommended Practice is to establish guidelines for the automatic transmission and hydraulic systems engineer to design cast iron sealing rings and select acceptable width, thickness, coatings, and other accepted design details.
The range of test conditions on the dynamometer shall be sufficient to determine the primary operating characteristics corresponding to the full range of vehicle operations. The characteristics to be determined are: a Torque ratio versus speed ratio and output speed. b Input speed versus speed ratio and output speed. c Efficiency versus speed ratio and output speed. d Capacity factor versus speed ratio and output speed. e Input torque versus input speed. NOTE: For more information about these characteristics and the design of hydrodynamic drives, see "Design Practices--Passenger Car Automatic Transmissions," SAE Advances in Engineering, Vol. 5.
The range of test conditions on the dynamometer shall be sufficient to determine the primary operating characteristics corresponding to the full range of vehicle operations. The characteristics to be determined are: 1 Torque ratio versus speed ratio and output speed. 2 Input speed versus speed ratio and output speed. 3 Efficiency versus speed ratio and output speed. 4 Capacity factor versus speed ratio and output speed. 5 Input torque versus input speed. Note: For more information about these characteristics and the design of hydrodynamic drives, see “Design Practices-Passenger Car Automatic Transmissions,” SAE Advances in Engineering, Vol. 5.
The range of test conditions on the dynamometer shall be sufficient to determine the primary operating characteristics corresponding to the full range of vehicle operations. The characteristics to be determined are: a Torque ratio versus speed ratio and output speed b Input speed versus speed ratio and output speed c Efficiency versus speed ratio and output speed d Capacity factor versus speed ratio and output speed e Input torque versus input speed NOTE: For more information about these characteristics and the design of hydrodynamic drives, refer to “Design Practices: Passenger Car Automatic Transmissions,” SAE Advances in Engineering, AE-18 (Third Ed.) or AE-29 (Fourth Ed.).
The range of test conditions on the dynamometer shall be sufficient to determine the primary operating characteristics corresponding to the full range of vehicle operations. The characteristics to be determined are: a Torque ratio versus speed ratio and output speed b Input speed versus speed ratio and output speed c Efficiency versus speed ratio and output speed d Capacity factor versus speed ratio and output speed e Input torque versus input speed NOTE: For more information about these characteristics and the design of hydrodynamic drives, refer to “Design Practices: Passenger Car Automatic Transmissions,” SAE Advances in Engineering, AE-18 (Third Ed.) or AE-29 (Fourth Ed.).
The range of test conditions on the dynamometer shall be sufficient to determine the primary operating characteristics corresponding to the full range of vehicle operations. The characteristics to be determined are: a Torque ratio versus speed ratio and output speed b Input speed versus speed ratio and output speed c Efficiency versus speed ratio and output speed d Capacity factor versus speed ratio and output speed e Input torque versus input speed NOTE: For more information about these characteristics and the design of hydrodynamic drives, see “Design Practices—Passenger Car Automatic Transmissions,” SAE Advances in Engineering, AE18 or AE29
The range of test conditions on the dynamometer shall be sufficient to determine the primary operating characteristics corresponding to the full range of vehicle operations. The characteristics to be determined are: a Torque ratio versus speed ratio and output speed b Input speed versus speed ratio and output speed c Efficiency versus speed ratio and output speed d Capacity factor versus speed ratio and output speed e Input torque versus input speed NOTE—For more information about these characteristics and the design of hydrodynamic drives, see “Design Practices—Passenger Car Automatic Transmissions,” SAE Advances in Engineering, Vol. 5.
Since the torque converter and fluid coupling are commonly used components of automatic transmissions in industry, the SAE appointed a committee to standardize terminology, test procedure, data recording, design symbols, and so forth, in this field. The following committee recommendations will facilitate a clear understanding for engineering discussions, comparisons, and the preparation of technical papers. The recommended usages represent the predominant practice or the acceptable practice. Where agreement is not complete, alternates have been included for clarification. This SAE Recommended Practice deals only with the physical parts and dimensions and does not attempt to standardize the design considerations, such as the actual fluid flow angle resulting from the physical blade shape.