Rationale: Note 10 on Dwg. AS1005 that states when machining from bar stock the center body dimensions shall conform to AS1376 Table II
I believe Table II should read Table I and is a typo for the following reasons below: (Note part# AS1005W060606 is the example)
AS1005 dwg for size 06 requires a .120 Min. wall thickness at center body section that cannot be met following table II (works out to .077 undersize) versus .132 following table I (conforming)
Also table I references parts AS1003 thru AS1006 and table II does not referencing parts AS4130 thru AS4141?
Also Dwg.’s of other fittings referenced by table I in the notes read “when machining from bar stock the center body dimensions shall conform to AS1376 Table I”