Technical Paper

Simplifying the Structural Design of the Advanced Pedestrian Legform Impactor for Use in Standardized Testing

2018-04-03
2018-01-1049
The advanced Pedestrian Legform Impactor (aPLI) incorporates a number of enhancements for improved lower limb injury prediction capability with respect to its predecessor, the FlexPLI. The aPLI also incorporates a simplified upper body part (SUBP), connected to the lower limb via a mechanical hip joint, that expands the impactor’s applicability to evaluate pedestrian’s lower limb injury risk also in high-bumper cars.As the aPLI has been developed to be used in standardized testing, further considerations on the impactor’s manufacturability, robustness, durability, usability, and repeatability need to be accounted for.. The aim of this study is to define and verify, by means of numerical analysis, a battery of design modifications that may simplify the manufacturing and use of physical aPLIs, without reducing the impactors’ biofidelity. Eight candidate parameters were investigated in a two-step numerical analysis.
Technical Paper

Analysis of Windshield Wiper Reversal Impact and Its Suppression by Structural Design

2015-03-30
2015-01-0108
With the increasing of people's demand for comfort of vehicles, the noise generated by the reverse of windshield wiper causes wide attention. In this paper, as the front windshield wiper of one car is considered, the impacts of the preload of wiper lever spring, the torsional stiffness of blade neck and the flexible connection between the wiper arm and the wiper lever on the vibration excitation applied to the front windshield are analyzed based on the multi-body dynamic model of wiper system. The dynamic model includes the crank pivot, the four linkage mechanism, the wiper blades, the wiper arms and the windscreen glass which has been established considering with elastic contact between the wiper blade and the front windshield. Based on the analysis results the dimensions of cross-section of the wiper blade rubber and the flexible connection between the wiper arm and the wiper lever are designed to reduce the quick-return impact of wiper lever.
Journal Article

An Efficient, One-Dimensional, Finite Element Helical Spring Model for Use in Planar Multi-Body Dynamics Simulation

2013-04-08
2013-01-1118
The helical spring is one of fundamental mechanical elements used in various industrial applications such as valves, suspension mechanisms, shock and vibration absorbers, hand levers, etc. In high speed applications, for instance in the internal combustion engine or in reciprocating compressor valves, helical springs are subjected to dynamic and impact loading, which can result in a phenomenon called “surge”. Hence, proper design and selection of helical springs should consider modeling the dynamic and impact response. In order to correctly characterize the physics of a helical spring and its response to dynamic excitations, a comprehensive model of spring elasticity for various spring coil and wire geometries, spring inertial effects as well as contacts between the windings leading to a non-linear spring force behavior is required. In practical applications, such models are utilized in parametric design and optimization studies.
Technical Paper

Whole-Body Response to Pure Lateral Impact

2010-11-03
2010-22-0014
The objective of the current study was to provide a comprehensive characterization of human biomechanical response to whole-body, lateral impact. Three approximately 50th-percentile adult male PMHS were subjected to right-side pure lateral impacts at 4.3 ± 0.1 m/s using a rigid wall mounted to a rail-mounted sled. Each subject was positioned on a rigid seat and held stationary by a system of tethers until immediately prior to being impacted by the moving wall with 100 mm pelvic offset. Displacement data were obtained using an optoelectronic stereophotogrammetric system that was used to track the 3D motions of the impacting wall sled; seat sled, and reflective targets secured to the head, spine, extremities, ribcage, and shoulder complex of each subject. Kinematic data were also recorded using 3-axis accelerometer cubes secured to the head, pelvis, and spine at the levels of T1, T6, T11, and L3. Chest deformation in the transverse plane was recorded using a single chestband.
Technical Paper

Investigation of Upper Body and Cervical Spine Kinematics of Post Mortem Human Subjects (PMHS) during Low-Speed, Rear-End Impacts

2009-04-20
2009-01-0387
A total of eight low-speed, rear-end impact tests using two Post Mortem Human Subjects (PMHS) in a seated posture are reported. These tests were conducted using a HYGE-style mini-sled. Two test conditions were employed: 8 kph without a headrestraint or 16 kph with a headrestraint. Upper-body kinematics were captured for each test using a combination of transducers and high-speed video. A 3-2-2-2-accelerometer package was used to measure the generalized 3D kinematics of both the head and pelvis. An angular rate sensor and two single-axis linear accelerometers were used to measure angular speed, angular acceleration, and linear acceleration of T1 in the sagittal plane. Two high-speed video cameras were used to track targets rigidly attached to the head, T1, and pelvis. The cervical spine kinematics were captured with a high-speed, biplane x-ray system by tracking radiopaque markers implanted into each cervical vertebra.
Technical Paper

Numerical Investigations of Interactions between the Knee-Thigh-Hip Complex with Vehicle Interior Structures

2005-11-09
2005-22-0005
Although biomechanical studies on the knee-thigh-hip (KTH) complex have been extensive, interactions between the KTH and various vehicular interior design parameters in frontal automotive crashes for newer models have not been reported in the open literature to the best of our knowledge. A 3D finite element (FE) model of a 50th percentile male KTH complex, which includes explicit representations of the iliac wing, acetabulum, pubic rami, sacrum, articular cartilage, femoral head, femoral neck, femoral condyles, patella, and patella tendon, has been developed to simulate injuries such as fracture of the patella, femoral neck, acetabulum, and pubic rami of the KTH complex. Model results compared favorably against regional component test data including a three-point bending test of the femur, axial loading of the isolated knee-patella, axial loading of the KTH complex, axial loading of the femoral head, and lateral loading of the isolated pelvis.
Technical Paper

Development of a Biofidelic Flexible Pedestrian Leg-form Impactor (Flex-PLI 2004) and Evaluation of its Biofidelity at the Component Level and at the Assembly Level

2005-04-11
2005-01-1879
JAMA-JARI has developed a biofidelic flexible pedestrian leg-form impactor (Flex-PLI 2004) by making several modifications to the Flex-PLI 2003 to improve usability, durability and biofidelity. Biofidelity evaluation for the Flex-PLI 2004 was estimated at the component level (thigh, knee, and leg individually) as well as at the assembly level (thigh-knee-leg complex), using an objective impactor biofidelity evaluation system based on a method developed by Rhule et al. to eliminate any subjective prejudice in an impactor biofidelity evaluation. Applying the biofidelity evaluation system to the Flex-PLI 2004, the average impactor biofidelity rank (IBR) score became 1.22 at the component level and 1.26 at the assembly level. These IBR scores mean that the Flex-PLI 2004 has good biofidelity at the component level as well as at the assembly level.
Technical Paper

Brain Injury Prediction for Indy Race Car Drivers Using Finite Element Model of the Human Head

2004-11-30
2004-01-3539
The objective of this work was to evaluate a new tool for assessing brain injury. Many race car drivers have suffered concussion and other brain injuries and are in need of ways of evaluating better head protective systems and equipment. Current assessment guidelines such as HIC may not be adequate for assessing all scenarios. Finite element models of the brain have the potential to provide much better injury prediction for any scenario. At a previous Motorsports conference, results of a MADYMO model of a racing car and driver driven by 3-D accelerations recorded in actual crashes were presented. Model results from nine cases, some with concussion and some not, yielded head accelerations that were used to drive the Wayne State University Head Injury Model (WSUHIM). This model consists of over 310,000 elements and is capable of simulating direct and indirect impacts. It has been extensively validated using published cadaveric test data.
Technical Paper

Sled Test Evaluation of Racecar Head/Neck Restraints Revisited

2004-11-30
2004-01-3516
At the 2002 MSEC, we presented a paper on the sled test evaluation of racecar head/neck restraint performance (Melvin, et al. 2002). Some individuals objected to the 3 msec clip filtering procedures used to eliminate artifactual spikes in the neck tension data for the HANS® device. As a result, we are presenting the same test data with the spikes left in the neck force data to reassure those individuals that these spikes did not significantly affect the results and conclusions of our original paper. In addition we will add new insights into understanding head/neck restraint performance gained during two more years of testing such systems. This paper re-evaluates the performance of three commercially available head/neck restraint systems using a stock car seating configuration and a realistic stock car crash pulse. The tests were conducted at an impact angle of 30 degrees to the right, with a midsize male Hybrid III anthropomorphic test device (ATD) modified for racecar crash testing.
Technical Paper

Below Knee Impact Responses using Cadaveric Specimens

2004-11-01
2004-22-0004
Knee injuries represent about 10% of all injuries suffered during car crashes. Efforts to assess the injury risk to the posterior cruciate ligament (PCL) have been based on a study available in the literature (Viano et al., 1978), in which only two of the five knees tested had PCL ruptures. The aims of the current study were to repeat the study with a higher number of samples, study the effects of other soft tissues on knee response, and assess the adequacy of the experimental setup for the identification of a PCL tolerance. A total of 14 knees were tested using a high-speed materials testing machine. Eight were intact knees (with the patella and all the muscular and ligamentous structures), three were PCL-only knees (patella and all the muscular and ligamentous structures other than the PCL removed), and the last three were PCL-only knees with the tibia protected from bending fracture.
Technical Paper

Effect of Head-Neck Position on Cervical Facet Stretch of Post Mortem Human Subjects during Low Speed Rear End Impacts

2004-11-01
2004-22-0015
The purpose of this study was to determine the effect of head-neck position on cervical facet stretch during low speed rear end impact. Twelve tests were conducted on four Post Mortem Human Subjects (PMHS) in a generic bucket seat environment. Three head positions, namely Normal (neutral), Zero Clearance between the head and head restraint, and Body Forward positions were tested. A high-speed x-ray system was used to record the motion of cervical vertebrae during these tests. Results demonstrate that: a) The maximum mean facet stretch at head restraint contact occurs at MS4 and MS5 for the Body Forward condition, b) The lower neck flexion moment, prior to head contact, shows a non-linear relationship with facet stretch, and c) “Differential rebound” during rear end impact increases facet stretch.
Technical Paper

Improvement of Foot FE Model Based on the Movement of Bones during Heel Impact

2004-03-08
2004-01-0313
Frontal vehicle collisions often result in foot injury of the front seat occupant. Therefore, it is very important to understand the mechanism of the foot injury. For that purpose, several impact experiments have been conducted using a partial human lower extremity. In addition, recently several impact response analyses using a human FE model have been conducted to understand the mechanism. In the present circumstances, a verified FE model is needed, and the verification of kinematical biofidelity is very important in the first place. In this connection, a foot FE model (based on an existing human FE model) was improved to create a foot FE model, which can be used for study of foot injury mechanism in this research. And the kinematics of foot bones of the model was verified by comparing the bone movements of the FE model with the movement of human foot during heel impact.
Technical Paper

Development of an FE Flexible Pedestrian Leg-form Impactor (Flex-PLI 2003R) Model and Evaluation of its Biofidelity

2004-03-08
2004-01-1609
A biofidelic flexible pedestrian leg-form impactor, called Flex-PLI, was developed by the Japan Automobile Manufactures Association, Inc. (JAMA) and the Japan Automobile Research Institute (JARI). Its latest version is called Flex-PLI 2003. The Flex-PLI 2003 responses have been validated at the component level (thigh, leg, and knee independently) but not at the assembly level (thigh-knee-leg complex). Furthermore, there was no FE Flex-PLI model. This research developed a FE Flex-PLI 2003R model (Flex-PLI 2003R means that the thigh and leg mass of Flex-PLI 2003 is adjusted to AM 50). The FE Flex-PLI 2003R model biofidelity has been evaluated at both the component level and the assembly level, where it demonstrated high biofidelity.
Technical Paper

Injury Pattern and Response of Human Thigh under Lateral Loading Simulating Car-Pedestrian Impact

2004-03-08
2004-01-1603
The main objective of the present study is to determine experimentally the injury patterns and response of the human thigh in lateral impacts simulating more closely the real impact conditions in car-pedestrian accidents. We conducted in-vitro experiments on thirteen thighs of eight completely intact Post Mortem Human Subjects (PMHSs). The thigh was hit by a ram at a speed of 35 km/h at the mid-shaft of the femur in each completely intact PMHS. Since the effect of cumulative injuries should be avoided, each thigh was impacted only once. Three impact energies were used; 450J, 600J and 700J. The PMHS motion was not constrained so as to simulate the walking posture of a pedestrian. We analyzed the peak values of the impact force of the ram and the femur acceleration. Injury was assessed by dissecting the lower extremities.
Technical Paper

Development of a Biofidelic Flexible Pedestrian Legform Impactor

2003-10-27
2003-22-0020
The European Enhanced Vehicle-Safety Committee (EEVC) has proposed a test procedure to assess the protection vehicles provide to the lower extremity of pedestrians during a collision. This procedure utilizes a legform impactor developed by the Transport Research Laboratory (TRL). However, the TRL Pedestrian Legform Impactor (TRL-PLI) is composed of rigid long bones (cannot simulate the bone flexibility of the human) and rather stiff knee joint. The differences lead to a lack of biofidelity of the TRL-PLI, i.e., unnaturally stiff responses are observed. This study develops a biofidelic Flexible Pedestrian Legform Impactor (Flex-PLI) that can simulate human bone flexibility and human knee joint stiffness properly. The Flex-PLI can also measure many of the injury parameters, long bone strains at multiple locations, knee ligament elongations, and the compression forces between the femoral condyles and tibial plateau in comparison to the TRL-PLI.
Technical Paper

Advanced Human Modeling for Injury Biomechanics Research

2003-06-17
2003-01-2223
The two main motivations for Wayne State University (WSU) and Henry Ford Hospital (HFH) researchers to develop numerical human surrogates are advanced computing technology and a high-speed x-ray imaging device not available just a decade ago. This paper summarizes the capabilities and limitations of detailed component models of the human body, from head to foot, developed at WSU over the last decade (Zhang et al. 2001, Yang et al. 1998, Shah et al. 2001, Iwamoto et al. 2000, Lee et al. 2001 and Beillas et al. 2001). All of these models were validated against global response data obtained from relevant high-speed cadaveric tests. Additionally, some models were also validated against local kinematics of bones or soft tissues obtained using the high-speed x-ray system. All of these models have been scaled to conform to the key dimensions of a 50th percentile male.
Technical Paper

Injury Pattern and Tolerance of Human Pelvis Under Lateral Loading Simulating Car-pedestrian Impact

2003-03-03
2003-01-0165
Numerous studies of pelvic tolerance to lateral impact aimed at protecting car occupants have been conducted on Post Mortem Human Subjects (PMHSs) in a sitting posture. However, it remains unclear whether or not the results of these studies are relevant when evaluating the injury risk to walking pedestrians impacted by a car. Therefore, the first objective of the present study is to determine the injury tolerance and to describe the injury mechanisms of the human pelvis in lateral impacts simulating car-pedestrian accidents. The second objective is to obtain data for validation of mathematical models of the pelvis. In-vitro experiments were conducted on twelve PMHSs in simulated standing position. The trochanter of each PMHS was hit by a ram at speed of 32 km/h, and the pelvic motion was constrained by a bolt. This type of pelvic constraint is difficult to simulate in mathematical models.
Technical Paper

Mathematical Modeling of Crash-Induced Dynamic Loads on Race Car Drivers

2002-12-02
2002-01-3305
A MADYMO model of a racing car and driver was driven by 3-D accelerations recorded in actual crashes. Helmet, belt restraint, and padding characteristics were obtained from dynamics tests. Model results of HIC, head accelerations and neck forces and moments were studied along with driver injuries to provide insight into the efficacy of current injury assessment parameters used with the head and neck of crash test dummies. The results are also used to discuss the kinematics performance of the crash test dummy neck as modeled by the MADYMO version of the Hybrid III midsize male crash test dummy.
Technical Paper

Sled Test Evaluation of Racecar Head/Neck Restraints

2002-12-02
2002-01-3304
Recent action by some racecar sanctioning bodies making head/neck restraint use mandatory for competitors has resulted in a number of methods attempting to provide head/neck restraint. This paper evaluates the performance of a number of commercially available head/neck restraint systems using a stock car seating configuration and a realistic stock car crash pulse. The tests were conducted at an impact angle of 30 degrees to the right, with a midsize male Hybrid III anthropomorphic test device (ATD) modified for racecar crash testing. A six-point latch and link racing harness restrained the ATD. The goal of the tests was to examine the performance of the head/neck restraint without the influence of the seat or steering wheel. Three head/neck restraint systems were tested using a sled pulse with a 35 mph (56 km/h) velocity change and 50G peak deceleration. Three tests with three samples of each system were performed to assess repeatability.
Technical Paper

Structural Response of Lower Leg Muscles in Compression: A Low Impact Energy Study Employing Volunteers, Cadavers and the Hybrid III

2002-11-11
2002-22-0012
Little has been reported in the literature on the compressive properties of muscle. These data are needed for the development of finite element models that address impact of the muscles, especially in the study of pedestrian impact. Tests were conducted to characterize the compressive response of muscle. Volunteers, cadaveric specimens and a Hybrid III dummy were impacted in the posterior and lateral aspect of the lower leg using a free flying pendulum. Volunteer muscles were tested while tensed and relaxed. The effects of muscle tension were found to influence results, especially in posterior leg impacts. Cadaveric response was found to be similar to that of the relaxed volunteer. The resulting data can be used to identify a material law using an inverse method.