Standard

Truck Tractor Power Outlet for Trailer ABS

2024-01-10
CURRENT
J2247_202401
This SAE Recommended Practice identifies the minimum truck tractor electrical power output of the stop lamp and ABS (antilock brake system) circuits measured at the primary SAE J560 tractor trailer interface connector(s).
Standard

Circuit Breakers

2022-05-26
CURRENT
J553_202205
This SAE Standard defines the test conditions, procedures, and performance requirements for circuit breakers in ratings up to and including 200 A. The document includes automatic reset, modified reset, and manually reset types of circuit breakers for 12 VDC, 24 VDC, and 48 VDC electrical systems. Some circuit breakers may have dual voltage ratings (AC and DC); however, this document evaluates DC performance only.
Standard

Coiled Electrical Cable - Truck and Bus

2020-02-25
CURRENT
J2222_202002
This SAE Standard establishes the minimum performance and endurance requirements for coiled electrical cables used for hookup between trucks, trailers, and dollies for 12 VDC nominal applications. The component standards SAE J2394 (replaced SAE J1067) for cable and SAE J560 for connectors must be consulted to determine the complete performance and endurance requirements of the system. Related TMC Recommended Practices may be consulted for information associated with selection, installation, and inspection of these coiled electrical cables. This document is intended to set out requirements for the majority of conditions rather than for specialized applications or environments.
Standard

Coiled Electrical Cable - Truck and Bus

2018-02-15
HISTORICAL
J2222_201802
This SAE Standard establishes the minimum performance and endurance requirements for coiled electrical cables used for hookup between trucks, trailers and dollies. The component standards SAE J2394 (replaced SAE J1067) for cable and SAE J560 for connectors must be consulted to determine the complete performance and endurance requirements of the system. Related TMC Recommended Practices may be consulted for information associated with selection, installation and inspection of these coiled electrical cables. This document is intended to set out requirements for the majority of conditions rather than for specialized applications or environments.
Standard

Seven Conductor Cable for ABS Power - Truck and Bus

2017-12-20
HISTORICAL
J2394_201712
This SAE standard establishes the minimum construction and performance requirements for seven conductor 1/8-2/10-4/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications. While the document’s title refers to ABS Power to differentiate the document from the SAE J1067 standard that it supersedes, the scope applies to both the primary green cable for powering ABS and lighting and the yellow auxiliary cable of the same construction.
Standard

Positive Temperature Coefficient Overcurrent Protection Devices (PTCs)

2014-12-03
CURRENT
J2685_201412
This SAE Recommended Practice defines the test conditions, procedures, and performance requirements for PTC (positive temperature coefficient of resistance) overcurrent protection devices. PTCs are typically either polymeric (PPTC) or ceramic (CPTC). It is important to note battery voltages versus powernets/system voltage versus max battery voltages: (12 V/14 V/16 V, 24 V/28 V/32 V, and 36 V/42 V/58 V). All voltages are DC. These devices are typically rated with a maximum operating voltage, which for vehicular systems need to be 16 V (for 12 V batteries), 32 V (for 24 V batteries), and 58 V (for 36 V batteries/42 V powernets). PTC devices are considered to be self-resetting after responding to overcurrent conditions and after such condition has been removed from the affected circuit containing the PTC.
Standard

Combination 11 Conductors and 4 Pairs ECBS Cable

2013-04-09
HISTORICAL
J2742_201304
This SAE standard establishes the minimum construction and performance requirements for a combination cable consisting of 11 conductors and 4 twisted pairs for use on trucks, trailers, and dollies in conjunction with SAEJ2691. (15 pole connectors.) The cable includes both power and unjacketed SAE J1939-15 paired signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

Seven Conductor Cable for ABS Power - Truck and Bus

2013-02-01
HISTORICAL
J2394_201302
This SAE standard establishes the minimum construction and performance requirements for seven conductor 1/8-2/10-4/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications. While the document’s title refers to ABS Power to differentiate the document from the SAE J1067 standard that it supersedes, the scope applies to both the primary green cable for powering ABS and lighting and the yellow auxiliary cable of the same construction.
Standard

Coiled Electrical Cable - Truck and Bus

2012-10-24
HISTORICAL
J2222_201210
This SAE Standard establishes the minimum performance and endurance requirements for coiled electrical cables used for hookup between trucks, trailers and dollies. The component standards SAE J2394 (replaced SAE J1067) for cable and SAE J560 for connectors must be consulted to determine the complete performance and endurance requirements of the system. Related TMC Recommended Practices may be consulted for information associated with selection, installation and inspection of these coiled electrical cables. This document is intended to set out requirements for the majority of conditions rather than for specialized applications or environments.
Standard

Coiled Electrical Cable—Truck and Bus

2007-06-12
HISTORICAL
J2222_200706
This SAE Standard establishes the minimum performance and endurance requirements for coiled electrical cables used for hookup between trucks, trailers and dollies. The component standards SAE J2394 (replaced SAE J1067) for cable and SAE J560 for connectors must be consulted to determine the complete performance and endurance requirements of the system. Related TMC Recommended Practices may be consulted for information associated with selection, installation and inspection of these coiled electrical cables. This document is intended to set out requirements for the majority of conditions rather than for specialized applications or environments.
Standard

Positive Temperature Coefficient Overcurrent Protection Devices (PTCs)

2006-05-18
HISTORICAL
J2685_200605
This SAE Recommended Practice defines the test conditions, procedures, and performance requirements for PTC (positive temperature coefficient of resistance) overcurrent protection devices. PTCs are typically either polymeric (PPTC) or ceramic (CPTC). It is important to note battery voltages versus powernets/system voltage versus max battery voltages: (12 V/14 V/16 V, 24 V/28 V/32 V, and 36 V/42 V/58 V). All voltages are DC. These devices are typically rated with a maximum operating voltage, which for vehicular systems need to be 16 V (for 12 V batteries), 32 V (for 24 V batteries), and 58 V (for 36 V batteries/42 V powernets). PTC devices are considered to be self-resetting after responding to overcurrent conditions and after such condition has been removed from the affected circuit containing the PTC.
Standard

Heavy-Duty Wiring Systems for On-Highway Trucks

2004-05-10
HISTORICAL
J2202_200405
This SAE Recommended Practice is intended to describe the application of the primary wiring distribution system of less than 50 V and includes cable sizes 0.5 to 19 mm2 on heavy-duty on-highway trucks. The document identifies appropriate operating performances requirements. This document excludes the male to female connection of the SAE J560 and ISO 3731 connectors.
Standard

Connection and Accessory Locations for Towing Multiple Trailers

2003-08-29
HISTORICAL
J849_200308
This SAE Recommended Practice establishes the recommended locations for the air brake and electrical connections for towing multiple trailers. It applies to all commercial trailers except drop frame and car haul types.