Standard

Voltage Regulation and Limits

2022-12-16
CURRENT
J3226_202212
This document defines the test procedures and performance limits of steady state and transient voltage characteristics for 12 V, 24 V, or 48 V electrical power generating systems used in commercial ground vehicles.
Standard

Inverter Requirements for Class Eight Trucks - Truck and Bus

2022-06-07
WIP
J2697
This SAE Recommended Practice is intended to describe the application of single-phase DC to AC inverters, and bidirectional inverter/chargers, which supply power to ac loads in Class heavy duty on-highway trucks (10K GVW). The document identifies appropriate operating performance requirements and adds some insight into inverter selection. - This document applies to factory and after-market installed DC-to-AC inverter systems (Including inverter chargers) providing up 3000 W of 120 VAC line-voltage power as a convenience for operator and passenger use. Such inverters are intended to power user loads not essential to vehicle Operation or safety (e.g., HVAC, TV, microwave ovens, battery chargers for mobile phones or laptop computers, audio equipment, etc.). - Systems incorporate the inverter itself as well as the input, output, control, and signal wiring associated with the inverter.
Standard

Circuit Breakers

2022-05-26
CURRENT
J553_202205
This SAE Standard defines the test conditions, procedures, and performance requirements for circuit breakers in ratings up to and including 200 A. The document includes automatic reset, modified reset, and manually reset types of circuit breakers for 12 VDC, 24 VDC, and 48 VDC electrical systems. Some circuit breakers may have dual voltage ratings (AC and DC); however, this document evaluates DC performance only.
Standard

Cable Marking for Circuit Identification in Multi-Voltage Power Distribution Systems

2021-01-13
CURRENT
J3176_202101
This SAE Standard establishes the minimum circuit identification and requirements for Multi-Voltage Power Distribution Systems (MVPDS) for use on trucks and buses. A Multi-Voltage Power Distribution System is one that distributes two or three voltages, up to 60 VDC, to power the controls, instruments, and devices.
Standard

Inverter Requirements for Class Eight Trucks - Truck and Bus

2020-11-18
CURRENT
J2697_202011
This SAE Recommended Practice is intended to describe the application of single-phase DC to AC inverters, and bidirectional inverter/chargers, which supply power to ac loads in Class heavy duty on-highway trucks (10K GVW). The document identifies appropriate operating performance requirements and adds some insight into inverter selection. This document applies to factory and after-market installed DC-to-AC inverter systems (Including inverter chargers) providing up 3000 W of 120 VAC line-voltage power as a convenience for operator and passenger use. Such inverters are intended to power user loads not essential to vehicle Operation or safety (e.g., HVAC, TV, microwave ovens, battery chargers for mobile phones or laptop computers, audio equipment, etc.). Systems incorporate the inverter itself as well as the input, output, control, and signal wiring associated with the inverter.
Standard

Heavy Duty High Speed Datalink Connector

2020-01-08
CURRENT
J2839_202001
This SAE Recommended Practice defines the performance requirements, size and mating interfaces for M12 style 4 and 5 pole Heavy Duty High Speed Datalink connection systems, and applies to both cable-to-cable and cable-to-device connectors.
Standard

Auxiliary Two-Conductor Electrical Power Connector for Truck-Trailer High-Power Jumper Cable

2019-08-20
CURRENT
J3082_201908
This SAE Standard provides the minimum requirements for high-power, two-conductor jumper cable plug and receptacle for truck-trailer jumper cable systems. It includes the test procedures, design, and performance requirements. This document covers receptacles rated 12 VDC nominal and at more than 30 A (amperes) up to and including 150 A, and is intended for a single circuit with one power conductor and one common return conductor. Single-conductor high-current connectors are not recommended for future designs because of inadequate ground return through fifth wheel/king pin. Cable size selection is to be made by the vehicle OEM for specific applications and the specific voltage drop requirements of those applications.
Standard

Recommended Practice for Identification of Standardized Truck and Tractor Electrical Circuits

2019-01-08
HISTORICAL
J2191_201901
This SAE document defines a recommended practice for implementing circuit identification for electrical power and signal distribution systems of the Class 8 trucks and tractors. This document provides a description of a supplemental circuit identifier that shall be utilized in conjunction with the original equipment manufacturer’s primary circuit identification as used in wire harnesses but does not include electrical or electronic devices which have pigtails. The supplemental circuit identifier is cross-referenced to a specified subsystem of the power and signal distribution system identified in Section 5.
Standard

Combination 11 Conductors and 2 Pairs ECBS Cable

2018-06-03
HISTORICAL
J2742_201806
This SAE standard establishes the minimum construction and performance requirements for a combination cable consisting of 11 conductors and 2 twisted pairs for use on trucks, trailers, and dollies in conjunction with SAE J2691. (15 pole connectors.) The cable includes both power and unjacketed SAE J1939-15 paired signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

Truck Tractor Power Output for Trailer ABS

2018-05-24
HISTORICAL
J2247_201805
This SAE Recommended Practice identifies the minimum truck tractor electrical power output of the stop lamp and ABS (antilock brake system) circuits measured at the primary SAE J560 tractor trailer interface connector(s).
Standard

Coiled Electrical Cable - Truck and Bus

2018-02-15
HISTORICAL
J2222_201802
This SAE Standard establishes the minimum performance and endurance requirements for coiled electrical cables used for hookup between trucks, trailers and dollies. The component standards SAE J2394 (replaced SAE J1067) for cable and SAE J560 for connectors must be consulted to determine the complete performance and endurance requirements of the system. Related TMC Recommended Practices may be consulted for information associated with selection, installation and inspection of these coiled electrical cables. This document is intended to set out requirements for the majority of conditions rather than for specialized applications or environments.
Standard

Seven Conductor Cable for ABS Power - Truck and Bus

2017-12-20
HISTORICAL
J2394_201712
This SAE standard establishes the minimum construction and performance requirements for seven conductor 1/8-2/10-4/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications. While the document’s title refers to ABS Power to differentiate the document from the SAE J1067 standard that it supersedes, the scope applies to both the primary green cable for powering ABS and lighting and the yellow auxiliary cable of the same construction.
Standard

Seven Conductor Cable - Truck and Bus

2016-10-25
HISTORICAL
J1067_201610
This SAE standard establishes the minimum construction and performance requirements for seven conductor 1/8-1/10-5/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications.
Standard

Circuit Breakers

2016-07-12
HISTORICAL
J553_201607
This SAE Standard defines the test conditions, procedures, and performance requirements for circuit breakers in ratings up to and including 200 A. The document includes automatic reset, modified reset, and manually reset types of circuit breakers for 12 V and 24 V DC electrical systems. Some circuit breakers may have dual voltage ratings (AC and DC), however, this document evaluates DC performance only.
Standard

Auxiliary Two Conductor Electrical Power Connector for Truck-Trailer High Power Jumper Cable

2015-11-24
HISTORICAL
J3082_201511
This SAE Standard provides the minimum requirements for high power two conductor jumper cable plug and receptacle for truck-trailer jumper cable systems. It includes the test procedures, design, and performance requirements. This document covers receptacles rated at more than 30A (Ampere) up to and including 150A and is intended for a single circuit with one power conductor and one common return conductor. Single conductor high current connectors are not recommended for future designs because of inadequate ground return through 5th wheel / king pin. Cable size selection is to be made by the vehicle OEM for specific applications and the specific voltage drop requirements of those applications. This SAE Standard covers two variants of high power two conductor connections: a heavy duty version with horizontally aligned pins, typically for lift-gate battery charging and a medium duty version with vertically aligned pins: typically for loads such as power tarpaulins.
Standard

Heavy Duty High Speed Datalink Connector

2015-07-08
HISTORICAL
J2839_201507
This SAE Recommended Practice defines the performance requirements, size and mating interfaces for M12 style 4 and 5 pole Heavy Duty High Speed Datalink connection systems, and applies to both cable-to-cable and cable-to-device connectors.
Standard

Recommended Practice for Identification of Standardized Truck and Tractor Electrical Circuits

2014-02-21
HISTORICAL
J2191_201402
This SAE document defines a recommended practice for implementing circuit identification for electrical power and signal distribution systems of the Class 8 trucks and tractors. This document provides a description of a supplemental circuit identifier that shall be utilized in conjunction with the original equipment manufacturer’s primary circuit identification as used in wire harnesses but does not include electrical or electronic devices which have pigtails. The supplemental circuit identifier is cross-referenced to a specified subsystem of the power and signal distribution system identified in Section 5.
Standard

Truck Tractor Power Output for Trailer ABS

2013-09-05
HISTORICAL
J2247_201309
This SAE Recommended Practice identifies the minimum truck tractor electrical power output of the stop lamp and ABS (antilock brake system) circuits measured at the primary SAE J560 tractor trailer interface connector(s).
Standard

Combination 11 Conductors and 4 Pairs ECBS Cable

2013-04-09
HISTORICAL
J2742_201304
This SAE standard establishes the minimum construction and performance requirements for a combination cable consisting of 11 conductors and 4 twisted pairs for use on trucks, trailers, and dollies in conjunction with SAEJ2691. (15 pole connectors.) The cable includes both power and unjacketed SAE J1939-15 paired signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.