This recommended practice contains dimensions and tolerances for spindles in the interface area. Interfacing components include axle spindle, spindle threads, bearing cones, bearing spacer, seal, and wheel hub. This recommended practice is intended for axles commonly used on Class 7 and 8 commercial vehicles. Included are SAE axle configurations FF, FL, I80, L, N, P, R, U, and W.
This specification covers crimp-style aluminum lug terminals and conductor splices for aluminum aircraft wire. Lug terminals and conductor splices are hereafter called “terminals.”
The AS81824 specification covers environment resistant, permanent crimp type, splices having heat shrinkable insulating sleeve and meltable environmental seals or heatless sealing sleeves. The splices may be used with tin, nickel, and silver-plated conductors in applications where the total temperature of the splice application does not exceed 200 °C or as specified in the detail specification.
This SAE Standard covers low voltage primary cable intended for use at a nominal system voltage of 60 VDC (25 VAC) or less in surface vehicle electrical systems. The tests are intended to qualify cables for normal applications with limited exposure to fluids and physical abuse.
This SAE Standard covers low voltage battery cable intended for use at a nominal system voltage of 60 VDC (25 VAC) or less in surface vehicle electrical systems. The tests are intended to qualify cables for normal applications with limited exposure to fluids and physical abuse.
This SAE Recommended Practice describes the test procedures for conducting free motion headform testing of heavy truck cab interior surfaces and components. A description of the test set-up, instrumentation, impact configuration, target locations, and data reduction is included.
This SAE Recommended Practice provides procedures and methods for testing service, spring applied parking, and combination brake actuators with respect to durability, function, and environmental performance. A minimum of six test units designated A, B, C, D, E, and F are to be used to perform all tests per 1.1 and 1.2.
This Recommended Practice is derived from OEM and tier-1 laboratory tests and applies to two-axle multipurpose passenger vehicles, or trucks with a GVWR above 4536 kg (10 000 pounds) equipped with hydraulic disc or drum service brakes. Before conducting testing for a specific brake sizes or under specific test conditions, review, agree upon, and document with the test requestor any deviations from the test procedure. Also, the applicable criteria for the final test results and wear rates deemed as significantly different require definition, assessment, and proper documentation; especially as this will determine whether or not Method B testing is needed. This Recommended Practice does not evaluate or quantify other brake system characteristics such as performance, noise, judder, ABS performance, or braking under extreme temperatures or speeds. Minimum performance requirements are not part of this recommended practice.
This procurement specification covers solid rivets and hollow end rivets made from a corrosion and heat resistant steel of the type identified under the Unified Numbering System as UNS S66286 and of 80 ksi single shear strength at room temperature.
SAE J3078 provides test methods and criteria for the evaluation of the operator enclosure environment in earth-moving machinery as defined in ISO 6165. SAE J3078/1 gives the terms and definitions which are used in other parts of SAE J3078. It is applicable to Off-Road Self-Propelled Work Machines as defined in SAE J1116 and tractors and machinery for agriculture and forestry as defined in ANSI/ASAE S390.
This SAE Recommended Practice establishes methods to determine grade parking performance with respect to:a. Ability of the parking brake system to lock the braked wheels.b. The trailer holding or sliding on the grade, fully loaded, or unloaded.c. Applied manual effort.d. Unburnished or burnished brake lining friction conditions.e. Down and upgrade directions.
This technical information report (IR) presents a methodology to evaluate battery pack liquid leak tightness attributes to be used in a production line to satisfy the functional requirement for IPX7, water ingress requirement, and no sustainable coolant leakage for coolant circuits. The Equivalent Channel Method is used as a suggested production leak tightness requirement for a given battery pack design that will correlate and assure that the battery pack meets or exceeds its functional requirement. Obtaining the specific geometry of the Equivalent Channel (EC) for a given battery pack is done analytically and empirically in consideration of the product design limitations. This document is a precursor to J3277-1, which will present the practices to qualify that product leak tightness is equal or better than the maximum allowed EC for that product using applicable and commercially available leak test technologies.
This document covers the general physical, electrical, functional, testing, and performance requirements for conductive power transfer, primarily for vehicles using a conductive ACD connection capable of transferring DC power. It defines conductive power transfer methods, including the infrastructure electrical contact interface, the vehicle connection interface, the electrical characteristics of the DC supply, and the communication system. It also covers the functional and dimensional requirements for the vehicle connection interface and supply equipment interface. New editions of the documents shall be backwards compatible with the older editions. There are also sub-documents which are identified by a SAE J3105/1, SAE J3105/2, and SAE J3105/3. These will be specific requirements for a specific interface defined in the sub-document.