Refine Your Search

Topic

Author

Search Results

Standard

Nuts, Self-Locking, UNS N07001 730 °C, 1100 MPa, and 1210 MPa Procurement Specification for, Metric

2024-05-09
CURRENT
MA1943C
This procurement specification covers aircraft quality self-locking nuts for wrenching (hex, spline) and anchor (plate, gang channel, shank) types of nuts made from a corrosion and heat-resistant nickel-base alloy of the type identified under the Unified Numbering System as UNS N07001. Tension height nuts having overall length of threaded portion not less than 1.2 times the nominal thread diameter have 1210 MPa minimum tensile strength at room temperature. Shear height nuts having shorter threaded portion have 1100 MPa minimum tensile strength at room temperature. Maximum test temperature of parts is 730 °C.
Standard

Emergency Evacuation Slides, Ramps, Ramp/Slides, and Slide/Rafts

2024-05-01
CURRENT
AS8994
This AS provides the minimum performance requirements for the following types of inflatable emergency evacuation devices (hereinafter referred to as device[s]): 1 Type I - Inflatable Slide: A device suitable for assisting occupants in descending from a floor-level airplane exit or from an airplane wing to the ground. A Type I off-wing slide is a device that does not include a ramp. 2 Type II - Inflatable Slide/Raft: A device suitable for assisting occupants in descending from a floor-level airplane exit or an airplane wing to the ground that is also designed to be used as a life raft. A Type II off-wing slide/raft is a device that does not include a ramp. 3 Type III - Inflatable Exit Ramp: A device suitable for assisting occupants in descending from certain overwing exits to an airplane wing. 4 Type IV - Inflatable Ramp/Slide: A device suitable for assisting occupants from an overwing exit or airplane wing to the ground.
Standard

Splice, Electric, Crimp, Copper, Environment Resistant

2024-04-25
WIP
AS81824F
The AS81824 specification covers environment resistant, permanent crimp type, splices having heat shrinkable insulating sleeve and meltable environmental seals or heatless sealing sleeves. The splices may be used with tin, nickel, and silver-plated conductors in applications where the total temperature of the splice application does not exceed 200 °C or as specified in the detail specification.
Standard

Titanium Alloy Bars, Forgings and Forging Stock, 6.0Al - 6.0V - 2.0Sn, Solution Heat Treated and Aged

2024-04-25
CURRENT
AMS6935D
This specification covers a titanium alloy in the form of bars up through 4.000 inches (101.60 mm) in nominal diameter or least distance between parallel sides, inclusive, forgings of thickness up through 4.000 inches (101.60 mm), inclusive, with bars and forgings having a maximum cross-sectional area of 32 square inches (204.46 cm2), and stock for forging of any size (see 8.6).
Standard

Titanium Alloy Bars, Forgings, and Flash-Welded Rings, 5Al - 2.5V - 4Sn - 1Co - 0.8Fe Annealed

2024-04-25
CURRENT
AMS6903
This specification covers a titanium alloy in the form of bars, forgings, and flash-welded rings up through 12.000 inches (304.80 mm), inclusive, in diameter or least distance between parallel sides, and stock of any size for forging or flash-welded rings. Bars, forgings, and flash-welded rings with a nominal thickness of 3.000 inches (79.20 mm) or greater shall have a maximum cross-sectional area of 113 square inches (729 cm2) (see 8.5).
Standard

Low Voltage Primary Cable

2024-04-25
WIP
J1128
This SAE Standard covers low voltage primary cable intended for use at a nominal system voltage of 60 VDC (25 VAC) or less in surface vehicle electrical systems. The tests are intended to qualify cables for normal applications with limited exposure to fluids and physical abuse.
Standard

Low Voltage Battery Cable

2024-04-25
WIP
J1127
This SAE Standard covers low voltage battery cable intended for use at a nominal system voltage of 60 VDC (25 VAC) or less in surface vehicle electrical systems. The tests are intended to qualify cables for normal applications with limited exposure to fluids and physical abuse.
Standard

Liquid Leak Tightness Evaluation Methodology for EV Battery Packs Informational Report

2024-04-23
CURRENT
J3277_202404
This technical information report (IR) presents a methodology to evaluate battery pack liquid leak tightness attributes to be used in a production line to satisfy the functional requirement for IPX7, water ingress requirement, and no sustainable coolant leakage for coolant circuits. The Equivalent Channel Method is used as a suggested production leak tightness requirement for a given battery pack design that will correlate and assure that the battery pack meets or exceeds its functional requirement. Obtaining the specific geometry of the Equivalent Channel (EC) for a given battery pack is done analytically and empirically in consideration of the product design limitations. This document is a precursor to J3277-1, which will present the practices to qualify that product leak tightness is equal or better than the maximum allowed EC for that product using applicable and commercially available leak test technologies.