Standard

Procedure for Certification that Requirements for Mobile Air Conditioning System Components, Service Equipment, and Service Technician Training Meet SAE J Standards

2020-02-03
CURRENT
J2911_202002
This SAE standard provides manufacturers/marketers, testing facilities, and providers of technician training with a procedure for certifying compliance with the applicable standard. Manufacturers/marketers or sellers who advertise their products as certified to an SAE J standard shall follow this procedure. Certification of a product is voluntary; however, this certification process is mandatory for those advertising meeting SAE standard(s) requirements. Only certifying to this standard allows those claiming compliance to advertise that their product (unit), component, or service technician training meets all requirements of the applicable SAE standard. Certification of compliance to this and the appropriate standard and use of the SAE label on the product shall only be permitted after all the required information has been submitted to SAE International and it has been posted on the SAE website.
Standard

Procedure for Certification that Requirements for Mobile Air Conditioning System Components, Service Equipment, and Service Technician Training Meet SAE J Standards

2017-11-13
HISTORICAL
J2911_201711
This SAE Standard provides manufacturers/marketers, testing facilities and providers of technician training with a procedure for certifying compliance with the applicable standard. Manufacturers/marketers or sellers who advertise their products as Certified to an SAE J standard shall follow this procedure. Certification of a product is voluntary; however, this certification process is mandatory for those advertising meeting SAE Standard(s) requirements. Only certifying to this standard allows those claiming compliance to advertise that their product (unit), component, or service technician training meets all requirements of the applicable SAE standard. Certification of compliance to this and the appropriate standard and use of the SAE label on the product shall only be permitted after all the required information has been submitted to SAE International and it has been posted on the SAE web site.
Standard

Procedure for Certification that Requirements for Mobile Air Conditioning System Components, Service Equipment, and Service Technician Training Meet SAE J Standards

2016-12-02
HISTORICAL
J2911_201612
This SAE Standard provides manufacturers, testing facilities and providers of technician training with a procedure for certifying compliance with the applicable standard. Manufacturers or seller who advertise their products as Certified to an SAE J standard shall follow this procedure. Certification of a product is voluntary; however, this certification process is mandatory for those advertising meeting SAE Standard(s) requirements. Only certifying to this standard allows those claiming compliance to advertise that their product (unit), component, or service technician training meets all requirements of the applicable SAE standard. Certification of compliance to this and the appropriate standard and use of the SAE label on the product shall only be permitted after all the required information has been submitted to SAE International and it has been posted on the SAE web site.
Standard

HFC-134a Mobile Air Conditioning System Emission Chart

2007-07-12
HISTORICAL
J2727_200707
The original SAE J2727 “Leakage Chart” provided a rating system for comparing mobile A/C systems and was not intended to define mobile A/C system refrigerant leakage. It had been developed from industry experience of expected system refrigerant leakage based upon currently available technologies. The new “System Emissions Chart” now contained in this revision is intended to serve as a means of estimating the annual refrigerant emissions rate (grams per year) from new production A/C systems equipped with specified component technologies. It provides emission values for various component technologies that are currently available, and can be expanded as new technologies are commercialized. This document provides the information to develop an Excel file template “System Emissions Chart” for system emission analysis. The new chart includes automotive compressor technologies, for conventional mobile air conditioning systems as well as fully hermetic compressors.
Standard

HFC-134a (R-134a) Recovery/Recycling Equipment and Recovery/Recycling/Recharging for Mobile Air-Conditioning Systems

2006-12-05
HISTORICAL
J2788_200612
The purpose of this SAE Standard is to establish the specific minimum equipment performance requirements for recovery and recycling of HFC-134a that has been directly removed from, and is intended for reuse in, mobile air-conditioning (A/C) systems. It also is intended to establish requirements for equipment used to recharge HFC-134a to an accuracy level that meets Section 9 of this document and SAE J2099. The requirements apply to the following types of service equipment and their specific applications. a Recovery/Recycling Equipment, b Recovery/Recycling – Refrigerant Charging, c Refrigerant Recharging Equipment Only.
Standard

Safety and Containment of Refrigerant for Mechanical Vapor Compression Systems Used for Mobile Air-conditioning Systems

1999-03-01
HISTORICAL
J639_199903
This SAE Recommended Practice is restricted to mechanical vapor compression refrigerant systems that provide cooling for the occupant’s compartment. This document provides guidelines for refrigerant containment and safety for a mobile air-conditioning (A/C) system. It is not intended to restrict the use of, or further development of, other types of refrigeration systems for passenger compartment cooling. Should other systems be found practical at some future time, this document may be amended or an additional recommended safety practice drawn up for other types of systems. This document only addresses CFC-12 (R-12) and HFC-134a (R-134a) refrigerants. To prevent mobile A/C system refrigerant contamination, all other alternate refrigerants considered for automotive use require unique service fittings.
Standard

Recovery and Recycle Equipment for Mobile Automotive Air-Conditioning Systems

1999-02-01
HISTORICAL
J1990_199902
The purpose of this SAE Standard is to provide equipment specifications for CFC-12 (R-12) recycling equipment. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar CFC-12 (R-12) air-conditioning (A/C) systems. Systems used on mobile vehicles for refrigerating cargo that have hermetically sealed systems are not covered in this document. The equipment in this document is intended for use with refrigerant that has been directly removed from, and intended to be returned to, a mobile A/C system. Should other revisions due to operational or technical requirements occur, this document may be amended.
Standard

Standard of Purity for Use in Mobile Air-Conditioning Systems

1999-02-01
HISTORICAL
J1991_199902
This information applies to refrigerant used to service automobiles, light trucks, and other vehicles with similar CFC-12 (R-12) systems. Systems used on mobile vehicles for refrigerated cargo that have hermetically sealed, rigid pipe, are not covered in this document.
Standard

CFC-12 (R-12) Refrigerant Recovery Equipment for Mobile Automotive Air-Conditioning Systems

1999-02-01
HISTORICAL
J2209_199902
The purpose of this SAE Standard is to provide equipment specifications for CFC-12 (R-12) recovery for return to a refrigerant reclamation facility that will process it to the appropriate ARI Standard (Air Conditioning and Refrigerant Institute) or allow for recycling of the recovered refrigerant in equipment that is certified to meet the requirements of SAE J1991. Under the existing rule, the U.S. EPA requires refrigerant removed from a mobile air-conditioning (A/C) system using recovery equipment certified to meet SAE J2209 can only be recycled using equipment meeting SAE J1991 that is owned by the same company or individual. It is not acceptable that the refrigerant removed from a mobile A/C system, with this equipment, be directly returned to a mobile A/C system. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar CFC-12 (R-12) systems.
Standard

Compatibility of Retrofit Refrigerants with Air-Conditioning System Materials

1998-11-05
HISTORICAL
J1662_199811
The purpose of this SAE Recommended Practice is to provide criteria for determining the compatibility of air-conditioning (A/C) system materials/components with candidate retrofit refrigerants intended to replace CFC-12 (R12) in mobile A/C systems originally designed to use CFC-12 (R-12).
Standard

Procedure Retrofitting CFC-12 (R-12) Mobile Air-Conditioning Systems to HFC-134a (R-134a)

1998-11-01
HISTORICAL
J1661_199811
The purpose of this SAE Recommended Practice is to provide a service procedure for retrofitting a CFC-12 (R-12) system to HFC-134a (R-134a) while preserving performance and integrity of the air-conditioning (A/C) system. The steps outlined in this procedure are complete when combined with good service practices and the vehicle manufacturer's recommendations (if available) for retrofitting their models. Separate service equipment, for CFC-12 (R-12) and HFC-134a (R-134a), including refrigerant recovery/recycle (R/R), service manifolds, vacuum pumps, and charging equipment shall be used to preserve the purity of the refrigerants and the mobile A/C systems. This procedure will minimize release of refrigerant to the atmosphere, and will preserve the integrity of the recycled CFC-12 (R-12) and HFC-134a (R-134a) supplies. This document applies to A/C systems used to cool the passenger compartment of automobiles, light trucks, and other vehicles with similar CFC-12 (R-12) systems.
Standard

SERVICE HOSE FOR AUTOMOTIVE AIR CONDITIONING

1997-03-01
HISTORICAL
J2196_199703
This SAE Standard covers reinforced rubber, reinforced thermoplastic, or otherwise constructed hose, or hose assemblies, intended for conducting liquid and gaseous refrigerants for service connections from mobile air conditioning systems to service equipment such as a manifold gauge set and vacuum pumps or for use internally, in charging stations or service equipment intended for use in servicing mobile air-conditioning systems.
Standard

PERFORMANCE CRITERIA FOR ELECTRONIC REFRIGERANT LEAK DETECTORS

1995-08-01
HISTORICAL
J1627_199508
This SAE Standard applies to electronic probe-type leak detectors used to service motor vehicle passenger compartment air-conditioning systems. This document does not address any safety issues concerning their design or use.