Journal Article

Influence of Cold Start and Ambient Temperatures on Greenhouse Gas (GHG) Emissions, Global Warming Potential (GWP) and Fuel Economy for SI Car Real World Driving

2010-04-12
2010-01-0477
The transport sector is one of the major contributors to greenhouse gas emissions. This study investigated three greenhouse gases emitted from road transport using a probe vehicle: CO₂, N₂O and CH₄ emissions as a function of cold start and ambient temperatures. A real-world driving cycle has been developed at Leeds and referred as LU-BS, which has an urban free flow driving pattern. The test vehicle was driven on the same route by the same driver on different days with different ambient temperatures. All the journeys were started from cold. An in-vehicle FTIR emission measurement system was installed on a EURO2 emission compliance SI car for emissions measurement at a rate of 0.5 Hz. This emission measurement system was calibrated on a standard CVS measurement system and showed an excellent agreement on the CO₂ measurement with the CVS results. The N₂O and CH₄ were calibrated by calibration gas bottles.
Technical Paper

Reduction of Exhaust Emissions by a Synthetic Lubricating Oil with Higher Viscosity Grade and Optimized Additive Package for a Heavy Duty DI Diesel Engine Test

2008-10-06
2008-01-2489
A 10W-50 G4 synthetic lubricating oil (EULUBE oil) was tested on a heavy duty DI diesel engine under two steady state conditions. The exhaust emissions were measured and compared to a 10W-30 CF semi-synthetic lubricating oil. The EULUBE oil contained the friction reduction additive to improve the fuel economy. The engine used was a 6 cylinder, turbocharged, intercooled Perkins Phaser Engine, with emission compliance of EURO 2, fitted with an oxidation catalyst. The exhaust samples were taken both upstream and downstream of the catalyst. Gaseous and particulates emissions were measured. Particulate size distribution was measured using ELPI and SMPS. The particulate samples were analysed for VOF, carbon and ash. A MEXA7100 gas analysis system was used for legislated gas analysis such as CO, CO2, NOx and total hydrocarbons. The results showed a significant reduction by synthetic lubricating oil in gaseous hydrocarbon emissions, total particulate mass, particulate carbon and ash.
Technical Paper

The Use of a Water/Lube Oil Heat Exchanger and Enhanced Cooling Water Heating to Increase Water and Lube Oil Heating Rates in Passenger Cars for Reduced Fuel Consumption and CO2 Emissions During Cold Start.

2007-07-23
2007-01-2067
Lubricating oil takes all of the NEDC test cycle time to reach 90°C. Hence, this gives high friction losses throughout the test cycle, which leads to a significant increase in the fuel consumption. In real world driving, particularly in congested traffic, it is shown that lube oil warm-up is even slower than in the NEDC. Euro 1, 2 and 4 Ford Mondeo water and oil warm up rates in real world urban driving were determined and shown to be comparable with the results of Kunze et al. (2) for a BMW on the NEDC. This paper explores the use of forced convective heat exchange between the cooling water and the lube oil during the warm-up period. A technique of a step warm-up of the engine at 32 Nm at 2000 rpm (35% of peak power) was used and the engine lube oil and water temperature monitored. It was shown that the heat exchanger results in an increase in lube oil temperature by 4°C, which increased to 10°C if enhanced heat transfer to the water was used from an exhaust port heat exchanger.
Technical Paper

Influence of Oil Age on Particulate Size Distributions with an On Line Oil Recycler from an IDI Passenger Car Diesel Engine

2004-10-25
2004-01-2905
Mass weighted size distributions of particulate emissions as a function of oil age were investigated using a set of Anderson Impactors on an IDI passenger car engine test. This engine was fitted with an on-line bypass lubricating oil recycler aiming to extend the oil life, reduce fuel consumption and exhaust emissions. A stop start test cycle was used with a cold start each time and a typical cycle period of 2∼3 hours. The whole test was carried out for nearly 500 hours. The first 310 hours of testing were with the oil recycler fitted and thereafter the test continued with the oil recycler disconnected. The results show that 60∼80% of mass particulates were smaller than 1.1 μm in aerodynamic diameter with the oil recycler fitted and this percentage was reduced to 40∼60% after disconnection of the oil recycler. The changes in size distribution with oil age mainly happened in the size ranges of 1.1∼0.65 μm, 0.65∼0.43 μm and <0.43 μm.
Technical Paper

The Influence of an On Line Oil Recycler on Emissions from a Low Emission DI Diesel Engine as a Function of Oil Age

2001-09-24
2001-01-3617
A method of cleaning lubricating oil on line was investigated using a fine 1μm bypass particulate filter followed by a 150°C infra-red heater, to remove water and light diesel fractions in the oil. The impact of this oil recycler on diesel particulate and gaseous emissions was investigated over a 72 hour oil age. Comparison tests were undertaken without and with the recycler on a Euro 2 Perkins Phaser 180Ti, 6-cylinder, 6-litre, turbo-charged inter-cooled DI diesel engine fitted with an oxidation catalyst. Emissions were sampled from both upstream and downstream of the catalyst about every 10 hours. The tests were carried out at 2000rpm and 100kW with 473 Nm load. A stop start test cycle was used with a cold start each time and a typical test period of 2 hours. The results showed that this engine had extremely low particulate emissions and was well inside the Euro 2 emissions limits.
Technical Paper

The Influence of an On Line Oil Recycler on Oil Quality from a Bus in Service Using Synthetic Oil

2001-05-07
2001-01-1969
A method of cleaning lubricating oil on line was investigated using a one micron bypass particulate filter followed by an infra-red heater, to remove water, dissolved gases and light diesel fractions in the oil. The impact of this oil recycler on oil quality was studied using synthetic oil in an on-road bus test. The bus was of Euro-1 emissions standard and equipped with a Cummins 6 cylinder 8.3 litre turbo-charged inter-cooled DI engine. Comparisons tests were undertaken with and without the oil recycler for about 28,000 miles. Oil samples were analysed about every 2000 miles. The results showed that the on line oil recycler achieved significant improvements in the oil quality. With the recycler, the TBN depletion rate was reduced by 52%, the TAN increase rate was reduced by 27% and the carbon accumulation rate in the oil was reduced by 42%. The fuel dilution was reduced by the recycler.
Technical Paper

Oil Quality with Oil Age in an IDI Diesel Passenger Car Using an On Line Lubricating Oil Recycler Under Real World Driving

2001-05-07
2001-01-1898
A method of cleaning lubricating oil on line was investigated using a fine 1 micron bypass particulate filter, followed by an infra-red heater to remove water and light diesel fractions in the oil. A Ford 1.8 litre IDI diesel passenger car was investigated under real world driving conditions. Comparison was made with the oil quality without the recycler. All the tests were carried out on the same vehicle over 7000 miles with and without the recycler. The results showed that the on line oil recycler cleaning system reduced the rate of reduction of TBN and the rate of increase of TAN by 54% and 50% respectively. The reduction in the rate of carbon accumulation in the oil was 42%. There was also a reduction in fuel dilution. All the wear metals in the oil were greatly reduced by the recycler, the iron was reduced by 76%, the lead was reduced by 85% and the aluminum was totally removed.
Technical Paper

The Influence of an Oil Recycler on Emissions with Oil Age for a Refuse Truck Using in Service Testing

2001-03-05
2001-01-0623
A method of cleaning lubricating oil on line was investigated using a fine bypass particulate filter followed by an infra red heater. Two bypass filter sizes of 6 and 1 micron were investigated, both filter sizes were effective but the one micron filter had the greatest benefit. This was tested on two nominally identical EURO 1 emissions compliance refuse trucks, fitted with Perkins Phazer 210Ti 6 litre turbocharged intercooled engines and coded as RT320 and RT321. These vehicles had emissions characteristics that were significantly different, in spite of their similar age and total mileage. RT321 showed an apparent heavier black smoke than RT320. Comparison was made with the emissions on the same vehicles and engines with and without the on-line bypass oil recycler. Engine exhaust emissions were measured about every 400 miles. Both vehicles started the test with an oil drain and fresh lubricating oil.
Technical Paper

Improvements in Lubricating Oil Quality by an On Line Oil Recycler for a Refuse Truck Using in Service Testing

2001-03-05
2001-01-0699
A method of cleaning lubricating oil on line was investigated using a fine bypass particulate filter followed by an infra red heater. Two bypass filter sizes of 6 and 1 micron were investigated, both filter sizes were effective but the one micron filter had the greatest benefit. This was tested on two nominally identical EURO 1 emissions compliance refuse trucks, fitted with Perkins Phazer 210Ti 6 litre turbocharged intercooled engines and coded as RT320 and RT321. These vehicles had lubricating oil deterioration and emissions characteristics that were significantly different, in spite of their similar age and total mileage. RT321 showed an apparent heavier black smoke than RT320. Comparison was made with the oil quality and fuel and lubricating oil consumption on the same vehicles and engines with and without the on-line bypass oil recycler. Engine oils were sampled and analysed about every 400 miles. Both vehicles started the test with an oil drain and fresh lubricating oil.
Technical Paper

The Influence of an On Line Heated Lubricating Oil Recycler on Emissions from an IDI Passenger Car Diesel as a Function of Oil Age

2000-03-06
2000-01-0232
A method of cleaning diesel engine lubricating oil on-line was investigated using a bypass fine particulate filter followed by an infra-red heater to remove water vapour and light diesel fractions in the oil. The impact of this oil recycler on the gaseous and particulate emissions was investigated over a 300 hour oil age period. A Ford 1.8 litre IDI passenger car diesel engine was used with engine out emission sampled every 15-20 hours. The tests were carried out at 2500rpm (52% of the maximum speed) and 12.3 kW with 47 Nm load (43% of the maximum load and 29% of the maximum power). The EGR level at this condition was 15%. A stop start test cycle was used with a cold start each time and a typical test period of 2-3 hours. The results showed that the recycler had its greatest influence on emissions for fresh oil when there was a large reduction in particulate emissions due mainly to large reductions in the ash, carbon and unburned lubricating oil fractions.
Technical Paper

The Influence of an Oil Recycler on Lubricating Oil Quality with Oil Age for a Bus Using in Service Testing

2000-03-06
2000-01-0234
A method of cleaning lubricating oil on line was investigated using a fine bypass particulate filter followed by an infra red heater, to remove water and light diesel fractions in the oil. Two bypass filter sizes of 6 and 1 micron were investigated, both filter sizes were effective but the one micron filter had the greatest benefit. This was tested on two nominally identical Euro 2 emissions compliance single decker buses, fitted with Cummins 6 cylinder 8.3 litre turbocharged intercooled engines. These vehicles had oil deterioration and emissions characteristics that were significantly different, in spite of their similar age and total mileage. Comparison was made with the oil quality on the same vehicles and engines with and without the on-line recycler. Oil samples were analysed about every 2000 miles. All tests started with an oil drain and fresh lubricating oil.