Technical Paper
Simulation of Temperatures of Three Way Catalytic Converter for Motorcycles at Higher Temperatures
2023-10-24
2023-01-1815
For a quick reach to the operating temperatures, the three way catalytic converter is recently located closer to the engine and subjected to higher temperatures than before. At the same time, the three way catalytic converter has upper thermal limits. Therefore, the operating temperatures have to be estimated accurately in the early period of product development. In this research, the four analysis methods are linked with the one-dimensional engine cycle simulation to achieve the goals. Firstly, for the estimation of gas temperatures at the exhaust port of the engine, the combustion analysis using the 3D-CFD was conducted to accurately simulate the way the heat was generated. Then, for the estimation of heat dissipation from the exhaust system to the atmosphere, the heat conduction analysis coupled with the air flow analysis around the vehicle body using the 3D-CFD was conducted.