Technical Paper

Development of a Test Protocol for Spacecraft Post-Fire Atmospheric Cleanup and Monitoring

2009-07-12
2009-01-2470
Fire detection, post fire atmospheric monitoring, fire extinguishing, and post fire atmospheric cleaning are vital components of a spacecraft fire response system, Preliminary efforts focused on the technology evaluation of fire detection, post fire atmospheric monitoring and post fire cleanup systems under realistic conditions are described in this paper. While the primary objective of testing is to determine the performance of a smoke mitigation filter, supplemental evaluations measuring the smoke-filled chamber handheld Commercial Off The Shelf (COTS) atmospheric monitoring devices (combustion product monitors) are conducted. The test chamber consists of a 1.4 cubic meter (50 cu. ft.) volume containing a smoke generator.
Technical Paper

Development of Urine Receptacle Assembly for the Crew Exploration Vehicle

2008-06-29
2008-01-2144
The Urine Receptacle Assembly (URA) initially was developed for Apollo as a primary means of urine collection. The aluminum housing with stainless steel honeycomb insert provided all male crewmembers with a non-invasive means of micturating into a urine capturing device and then venting to space. The performance of the URA was a substantial improvement over previous devices but its performance was not well understood. The Crew Exploration Vehicle (CEV) program is exploring the URA as a contingency liquid waste management system for the vehicle. URA improvements are required to meet CEV requirements, including consumables minimization, flow performance, acceptable hygiene standards, crew comfort, and female crewmember capability. This paper presents the results of a historical review of URA performance during the Apollo program, recent URA performance tests on the reduced gravity aircraft under varying flow conditions, and a proposed development plan for the URA to meet CEV needs.
Journal Article

International Space Station USOS Crew Quarters Development

2008-06-29
2008-01-2026
The International Space Station (ISS) United States Operational Segment (USOS) currently provides a Temporary Sleep Station (TeSS) as crew quarters for one crewmember in the Laboratory Module. The Russian Segment provides permanent crew quarters (Kayutas) for two crewmembers in the Service Module. The TeSS provides limited electrical, communication, and ventilation functionality. A new permanent rack sized USOS ISS Crew Quarters (CQ) is being developed. Up to four CQs can be installed into the Node 2 element to increase the ISS crewmember size to six. The new CQs will provide private crewmember space with enhanced acoustic noise mitigation, integrated radiation reduction material, controllable airflow, communication equipment, redundant electrical systems, and redundant caution and warning systems.
Technical Paper

Waste Collector System Technology Comparisons for Constellation Applications

2007-07-09
2007-01-3227
The Waste Collection Systems (WCS) for space vehicles have utilized a variety of hardware for collecting human metabolic wastes. It has typically required multiple missions to resolve crew usability and hardware performance issues that are difficult to duplicate on the ground. New space vehicles should leverage off past WCS systems. Past WCS hardware designs are substantially different and unique for each vehicle. However, each WCS can be analyzed and compared as a subset of ‘technologies’ which encompass fecal collection, urine collection, air systems, and urine pretreatment systems. Technology components from the WCS of various vehicles can then be combined to reduce hardware mass and volume while maximizing use of previous technology and proven human-equipment interfaces. Analysis of past US and Russian WCS are compared and extrapolated to Constellation missions.
Technical Paper

Development of a Rapid Cycling CO2 and H2O Removal Sorbent

2007-07-09
2007-01-3271
The National Aeronautics and Space Administration's (NASA) planned future missions set stringent demands on the design of the Portable Life Support System (PLSS), requiring dramatic reductions in weight, decreased reliance on supplies and greater flexibility for Extravehicular Activity (EVA) duration and objectives. Use of regenerable systems that reduce weight and volume of the space suit life support system is of critical importance to NASA, both for low orbit operations and for long duration manned missions. The carbon dioxide and humidity control unit in the existing PLSS design is relatively large, since it has to remove and store eight hours worth of carbon dioxide (CO2). If the sorbent regeneration can be carried out during the EVA with a relatively high regeneration frequency, the size of the sorbent canister and weight can be significantly reduced.
Technical Paper

Rapid Cycling CO2 and H2O Removal System for EMU

2006-07-17
2006-01-2198
Future National Aeronautics and Space Administration (NASA)-planned missions set stringent demands on the design of the Portable Life Support Systems (PLSS), requiring dramatic reductions in weight, decreased reliance on supplies and greater flexibility on the types of missions. Use of regenerable systems that reduce weight and volume of the Extravehicular Mobility Unit (EMU) is of critical importance to NASA, both for low orbit operations and for long duration manned missions. TDA Research, Inc. (TDA) is developing a high capacity, rapid cycling sorbent to control CO2 and humidity in the space suit ventilation loop. The sorbent can be regenerated using space vacuum during the EVA, eliminating all duration-limiting elements in the life support system. This paper summarizes the results of the sorbent development and testing, and evaluation efforts.
Technical Paper

Corrosion Testing of Brazed Space Station IATCS Materials

2004-07-19
2004-01-2471
Increased nickel concentrations in the IATCS coolant prompted a study of the corrosion rates of nickel-brazed heat exchangers in the system. The testing has shown that corrosion is occurring in a silicon-rich intermetallic phase in the braze filler of coldplates and heat exchangers as the result of a decrease in the coolant pH brought about by cabin carbon dioxide permeation through polymeric flexhoses. Similar corrosion is occurring in the EMU de-ionized water loop. Certain heat exchangers and coldplates have more silicon-rich phase because of their manufacturing method, and those units produce more nickel corrosion product. Silver biocide additions did not induce pitting corrosion at silver precipitate sites.
Technical Paper

Active Thermal Control Systems for Lunar and Martian Exploration

1990-07-01
901243
Extended manned missions to the lunar and martian surfaces pose new challenges for active thermal control systems (ATCS's). Moderate-temperature heat rejection becomes a problem during the lunar day, when the effective sink temperature exceeds that of the heat-rejection system. The martian atmosphere poses unique problems for rejecting moderate-temperature waste heat because of the presence of carbon dioxide and dust. During a recent study, several ATCS options including heat pumps, radiator shading devices, and single-phase flow loops were considered. The ATCS chosen for both lunar and martian habitats consists of a heat pump integral with a nontoxic fluid acquisition and transport loop, and vertically oriented modular reflux-boiler radiators. The heat pump operates only during the lunar day. The lunar and martian transfer vehicles have an internal single-phase water-acquisition loop and an external two-phase ammonia rejection system with rotating inflatable radiators.
Technical Paper

A Fuel Cell Energy Storage System Concept for the Space Station Freedom Extravehicular Mobility Unit

1989-07-01
891582
The paper gives an update on an advanced development effort carried out under NASA Johnson Space Center (NASA/JSC) NAS 9-17775 by Ergenics Power Systems, Inc. (EPSI). The work was initiated in April 1987 to design and build a Fuel Cell Energy Storage System (FCESS) bench-test unit for the Space Station Freedom Extravehicular Mobility Unit (EMU). Fueled by oxygen and hydride stored hydrogen, the FCESS is being considered as an alternative to the EMU zinc-silver oxide battery. Superior cycle life and quick recharge are its main attributes. Design and performance of a non-venting 28V, 34 Ahr system with 7 amp rating are discussed. The FCESS is comprised of a 32-cell proton exchange membrane (PEM) stack, a metal hydride storage vessel and a control subsystem. The stack design incorporates passive product-water removal and thermal integration with the hydride vessel. The hydride vessel stores enough fuel for 5 hours.
Technical Paper

The Shuttle Orbiter Thermal Protection System Materials, Designs, and Flight Performance Overview

1983-07-11
831118
The design requirements for the Orbiter thermal protection system (TPS), the various TPS materials that are used, the different design approaches associated with each of the materials, and the performance experienced during the flight test program are described. The first five flights of the Orbiter Columbia have provided the necessary data to verify the TPS thermal performance, structural integrity, and reusability. The flight performance characteristics of each TPS material are discussed. This discussion is based on postflight inspections and postflight interpretation of the flight instrumentation data. The flights to date indicate that the thermal and structural design requirements for the Orbiter TPS have been met and that the overall performance has been outstanding.
Technical Paper

Regenerable Non-Venting Thermal Control Subsystem for Extravehicular Activity, 1983

1983-07-11
831151
With the advent of manned spacecraft opportunities requiring routine and complex extravehicular activities (EVA) a new concept for heat rejection is mandatory in order to realize maximum crewmember productivity. An optimum extravehicular mobility unit (EMU) thermal control system must be capable of successful operation without requiring expendables and without introducing contaminants into the environment, and be readily regenerable. This paper presents a regenerable non-venting thermal control subsystem requirements specification generated for a Shuttle-related EMU, identifies candidate concepts capable of fulfilling the requirements for each thermal control subsystem application, evaluates each candidate concept with respect to the subsystem requirements, and selects the best approach for each requirement.