Standard

Minimum Standards for Valve, High Pressure Oxygen, Cylinder Shut Off, Manually Operated

2023-04-26
CURRENT
AS1066B
This standard covers all types of manually operated high pressure oxygen, cylinder shut off valves for use in commercial aircraft. It is intended that the valve shall be attached to a pressure cylinder storing oxygen under a nominal pressure of 12.76 MPa (1850 psig) at 21 °C (70 °F). Upon opening the valve, oxygen will be permitted to discharge from the storage cylinder to the valve outlet and to other downstream components of the oxygen system. It shall also be possible to recharge the cylinder through the valve.
Standard

Protective Breathing Equipment for Flight Deck and Cabin Crew Members

2023-01-26
CURRENT
AIR825/10A
This SAE Aerospace Information Report (AIR) provides general information to aircraft engineers, regarding the types of Protective Breathing Equipment (PBE) configurations which are available, the intended functions of such equipment, and the technical approaches which may be used in accomplishing these functions. The term "PBE" or "Protective Breathing Equipment" has been used to refer to various types of equipment, which are used in a variety of applications. This way of using the terminology has been a source of confusion in the aviation industry. One objective of this AIR is to assist the reader in distinguishing between the types of PBE applications. A further objective is to assist in understanding the technical approaches which can be used in each of the major applications. Principles of PBE design are reviewed briefly.
Standard

Demand Oxygen Systems

2023-01-26
CURRENT
AIR825/9
This SAE Aerospace Information Report (AIR) describes the general operating principles of demand oxygen equipment, including variant types such as diluter-demand and pressure breathing equipment. The sources of oxygen supply that can be used in connection with a demand oxygen mask are in principle the same as those used for other oxygen dispensing devices. Except for mention of a few features specifically related to demand equipment, this document does not discuss oxygen sources in detail and the reader is advised to consult other applicable documents that describe the operation of oxygen sources for additional information.
Standard

Metabolic Simulator Testing Systems for Aviation Breathing Equipment

2021-08-11
CURRENT
ARP4259A
This Aerospace Recommended Practice (ARP) describes test equipment and methods used for testing closed cycle or semiclosed cycle breathing devices of short duration that are designed to operate with a high partial pressure of oxygen in the breathing circuit. It is intended to supplement ARP1109 and ARP1398 for applications involving closed cycle or semiclosed cycle breathing equipment which may be evaluated to the requirements of AS8031 and/or AS8047.
Standard

Introduction to Oxygen Equipment for Aircraft

2021-08-11
CURRENT
AIR825/1
The purpose of this document is to give the reader an overview of the document package which makes up AIR825, Introduction to Oxygen Equipment for Aircraft, and a basic overview (see Section 4) of the operational concerns driven by human physiology during altitude exposure.
Standard

Aircraft Oxygen Replenishment Coupling for Civil Transport Aircraft (Design Standard)

2021-03-09
WIP
AS1219B
This SAE Aerospace Design Standard defines a coupling, which is installed in a high pressure (1850 to 2000 psig) oxygen system of a civil transport aircraft for the purpose of mating to ground oxygen replenishment facilities. Dimensions developed from AND10089, Detail Specification Sheet for Fitting End, Design Standard, For Cone Connection.
Standard

Oxygen System and Component Cleaning

2020-10-19
CURRENT
ARP1176B
This SAE Aerospace Recommended Practice (ARP) provides recommended practices for the cleaning of aircraft oxygen equipment, both metallic and non-metallic articles, such as oxygen lines (tubes, hoses, etc.), components (including regulator and valve parts), cylinders, and ground-based equipment that may be used to support aircraft oxygen systems. This document also specifies work area details, methods for selecting suitable cleaning agents, cleaning methods, and test methods for verifying levels of cleanliness. The cleanliness coding scheme specified in this document provides a method for documenting minimum cleanliness level requirements and for identifying compliance.
Standard

Personal Protective Devices for Toxic and Irritating Atmospheres Air Transport Flight Deck (Sedentary) Crewmembers

2020-09-03
WIP
AS8031B
This SAE Aerospace Standard (AS) covers any protection system that serves the stated purpose. This document establishes minimum performance requirements for emergency equipment, which provides flight deck (sedentary) crewmembers with eye and respiratory protection from toxic atmospheres during in-flight emergencies. Defintion of sedentary: "sedentary" is herein defined as those flight deck crewmembers that remain seated at their flight deck stations throughout the emergency. For those "nonsedentary" cabin crewmembers whose duty it is to leave their flight station during an emergency (for example, to actively locate and fight an on-board fire).
Standard

Aircraft Oxygen Replenishment Coupling for Civil Transport Aircraft (Design Standard)

2020-02-28
CURRENT
AS1219A
This SAE Aerospace Design Standard defines a coupling, which is installed in a high pressure (1850 to 2000 psig) oxygen system of a civil transport aircraft for the purpose of mating to ground oxygen replenishment facilities. Dimensions developed from AND10089, Detail Specification Sheet for Fitting End, Design Standard, For Cone Connection.
Standard

Crewmember Demand Oxygen Mask for Transport Category Aircraft

2019-08-14
CURRENT
AS8026B
This standard covers oxygen masks and breathing valves used with both panel mounted and mask mounted demand and pressure-demand oxygen regulators. Mask mounted oxygen regulators are covered under other standards, but when the mask mounted regulator incorporates an integral exhalation valve, the performance of this valve shall meet the requirements of this standard.
Standard

Oxygen Cylinder Installation Guide

2019-04-11
CURRENT
ARP5021B
This document provides guidance for oxygen cylinder installation on commerical aircraft based on airworthiness requirements, and methods practiced within aerospace industry. It covers considerations for oxygen systems from beginning of project phase up to production, maintenance, and servicing. The document is related to requirements of DOT-approved oxygen cylinders, as well to those designed and manufactured to standards of ISO 11119. However, its basic rules may also be applicable to new development pertaining to use of such equipment in an oxygen environment. For information regarding oxygen cylinders itself, also refer to AIR825/12.
Standard

Passenger Hypoxia Protection Utilizing Oxygen Enriched Gas Mixtures

2018-10-18
CURRENT
AIR6036
Currently, existing civil aviation standards address the design and certification of oxygen dispensing devices that utilize oxygen sources supplying at least 99.5% oxygen. This Aerospace Information Report discusses issues relating to the use in the passenger cabin of oxygen enriched breathing gas mixtures having an oxygen content of less than 99.5% and describes one method of showing that passenger oxygen dispensing devices provide suitable hypoxia protection when used with such mixtures.
Standard

Fuel Versus Oxygen: Evaluations and Considerations

2018-10-18
CURRENT
AIR5648A
Specific federal aviation regulations (Titled 14 of the United States Code of Federal Regulations, or 14 CFR) define oxygen system requirements for an in-flight decompression incident. This AIR addresses the operational oxygen system requirements for a decompression incident that may occur at any point during a long-range flight, with an emphasis for a decompression at the equal time point (ETP). This AIR identifies fuel and oxygen management contingencies, and presents possible solutions for the efficient, safe, and optimum fuel/oxygen flight continuation. Oxygen management is a concern to all aircraft, such as single engine types that fly above 10 000 feet and use supplemental oxygen. This document provides a method which can help guide users in developing an oxygen solution for their aircraft.
Standard

Oxygen System and Component Cleaning

2018-10-18
HISTORICAL
ARP1176A
This SAE Aerospace Recommended Practice (ARP) provides recommended practices for cleaning aircraft oxygen equipment such as tubing, pieces, parts (including regulator and valve parts), cylinders and ground-based equipment that may be used to support aircraft oxygen systems. This revision introduces a cleanliness coding scheme that can be referenced as a requirement, and/or referenced to identify compliance to meeting such a requirement. These methods may apply to gaseous and liquid oxygen equipment. This document specifies work area details, methods to select suitable cleaning agents, cleaning methods, test methods to verify cleanliness level, and methods of packaging the components and parts after cleaning. Technicians designated to clean oxygen equipment must be qualified and trained to clean oxygen equipment. This ARP is applicable to metallic and non-metallic parts.
Standard

Minimum Standard for Gaseous Oxygen Pressure Reducers

2017-11-07
HISTORICAL
AS1248A
This standard applies to pressure reducers for gaseous breathing oxygen systems and for all performance profiles without regard to particular inlet or outlet pressures. Attention is given, however, to construction requirements for reducers with maximum supply pressures to 2250 psig (155 bar) and reduced pressures of 50 to 150 psig (3.4 to 10.5 bar).
Standard

Dynamic Testing Systems for Oxygen Breathing Equipment

2017-11-07
CURRENT
ARP1109B
This SAE Aerospace Recommended Practice (ARP) recommends performance requirements for test equipment used in dynamic testing of aviation oxygen breathing equipment. This document describes test equipment and methods used for testing continuous flow, demand and pressure demand regulators and their associated masks as well as filtered protective breathing devices; such articles of oxygen breathing or protective breathing equipment may be tested as individual components or as a complete system.