Journal Article
The Effects of Sulfur Poisoning and Desulfation Temperature on the NOx Conversion of LNT+SCR Systems for Diesel Applications
2010-04-12
2010-01-0300
A laboratory study was performed to assess the effects of sulfur poisoning and desulfation temperature on the NO conversion of a LNT+(Cu/SCR) in-situ system. Four LNT+(Cu/SCR) systems were aged for 4.5 hours without sulfur at 600, 700, 750, and 800°C using A/F ratio modulations to represent 23K miles of desulfations at different temperatures. NO conversion tests were performed on the LNT alone and on the LNT+SCR system using a 60 s lean/5 s rich cycle. The catalysts were then sulfur-poisoned at 400°C and desulfated four times and re-evaluated on the 60/5 tests. This test sequence was repeated 3 more times to represent 100K miles of desulfations. After simulating 23K miles of desulfations, the Cu-based SCR catalysts improved the NO conversion of the LNT at low temperatures (e.g., 300°C), although the benefit decreased as the desulfation temperature increased from 600°C to 800°C.