Standard

HFC-134a (R-134a) Refrigerant Recovery Equipment for Mobile Automotive Air-Conditioning Systems

1998-11-01
HISTORICAL
J1732_199811
The purpose of this SAE Standard is to provide equipment specifications for the recovery of HFC-134a (R-134a) refrigerant to be returned to a refrigerant reclamation facility that will process it to the appropriate ARI 700 Standard or allow for recycling of the recovered refrigerant to SAE J2210 specifications by using Design Certified equipment of the same ownership. It is not acceptable that the refrigerant removed from a mobile air-conditioning (A/C) system, with this equipment be directly returned to a mobile A/C system. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar HFC-134a (R-134a) A/C systems.
Standard

Procedure Retrofitting CFC-12 (R-12) Mobile Air-Conditioning Systems to HFC-134a (R-134a)

1998-11-01
HISTORICAL
J1661_199811
The purpose of this SAE Recommended Practice is to provide a service procedure for retrofitting a CFC-12 (R-12) system to HFC-134a (R-134a) while preserving performance and integrity of the air-conditioning (A/C) system. The steps outlined in this procedure are complete when combined with good service practices and the vehicle manufacturer's recommendations (if available) for retrofitting their models. Separate service equipment, for CFC-12 (R-12) and HFC-134a (R-134a), including refrigerant recovery/recycle (R/R), service manifolds, vacuum pumps, and charging equipment shall be used to preserve the purity of the refrigerants and the mobile A/C systems. This procedure will minimize release of refrigerant to the atmosphere, and will preserve the integrity of the recycled CFC-12 (R-12) and HFC-134a (R-134a) supplies. This document applies to A/C systems used to cool the passenger compartment of automobiles, light trucks, and other vehicles with similar CFC-12 (R-12) systems.
Standard

Recovery and Recycle Equipment for Mobile Automotive Air-Conditioning Systems

1999-02-01
HISTORICAL
J1990_199902
The purpose of this SAE Standard is to provide equipment specifications for CFC-12 (R-12) recycling equipment. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar CFC-12 (R-12) air-conditioning (A/C) systems. Systems used on mobile vehicles for refrigerating cargo that have hermetically sealed systems are not covered in this document. The equipment in this document is intended for use with refrigerant that has been directly removed from, and intended to be returned to, a mobile A/C system. Should other revisions due to operational or technical requirements occur, this document may be amended.
Standard

EXTRACTION AND RECYCLE EQUIPMENT FOR MOBILE AUTOMOTIVE AIR-CONDITIONING SYSTEMS

1989-10-01
HISTORICAL
J1990_198910
The purpose of this document is to provide equipment specifications for CFC-12 (R-12) recycling and/or recovery, and recharging systems. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar CFC-12 systems. Systems used on mobile vehicles for refrigerated cargo that have hermetically sealed systems are not covered in this document.
Standard

EXTRACTION AND RECYCLE EQUIPMENT FOR MOBILE AUTOMOTIVE AIR-CONDITIONING SYSTEMS

1992-03-01
HISTORICAL
J1990_199203
The purpose of this SAE Standard is to provide equipment specifications for CFC-12 (R-12) recycling equipment. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar CFC-12 air-conditioning systems. Systems used on mobile vehicles for refrigerated cargo that have hermetically sealed systems are not covered in this document. The equipment in this document is intended for use with refrigerant that has been directly removed from, and intended to be returned to, a mobile air-conditioning system. Should other revisions due to operational or technical requirements occur, this document may be amended.
Standard

STANDARD OF PURITY FOR USE IN MOBILE AIR-CONDITIONING SYSTEMS

1989-10-01
HISTORICAL
J1991_198910
This information applies to refrigerant used to service automobiles, light trucks, and other vehicles with similar CFC-12 systems. Systems used on mobile vehicles for refrigerated cargo that have hermetically seated, rigid pipe are not covered in this document.
Standard

Standard of Purity for Use in Mobile Air-Conditioning Systems

1999-02-01
HISTORICAL
J1991_199902
This information applies to refrigerant used to service automobiles, light trucks, and other vehicles with similar CFC-12 (R-12) systems. Systems used on mobile vehicles for refrigerated cargo that have hermetically sealed, rigid pipe, are not covered in this document.
Standard

CFC-12 (R-12) EXTRACTION EQUIPMENT FOR MOBILE AUTOMOTIVE AIR-CONDITIONING SYSTEMS

1992-06-01
HISTORICAL
J2209_199206
The purpose of this SAE Recommended Practice is to provide equipment specifications for CFC-12 (R-12) recovery for return to a refrigerant reclamation facility that will process it to ARI standard 700-88 as a minimum (Air Conditioning and Refrigerant Institute). It is not acceptable that the refrigerant removed from a mobile air-conditioning system, with this equipment, be directly returned to a mobile air-conditioning system. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar R-12 systems.
Standard

CFC-12 (R-12) Refrigerant Recovery Equipment for Mobile Automotive Air-Conditioning Systems

1999-02-01
HISTORICAL
J2209_199902
The purpose of this SAE Standard is to provide equipment specifications for CFC-12 (R-12) recovery for return to a refrigerant reclamation facility that will process it to the appropriate ARI Standard (Air Conditioning and Refrigerant Institute) or allow for recycling of the recovered refrigerant in equipment that is certified to meet the requirements of SAE J1991. Under the existing rule, the U.S. EPA requires refrigerant removed from a mobile air-conditioning (A/C) system using recovery equipment certified to meet SAE J2209 can only be recycled using equipment meeting SAE J1991 that is owned by the same company or individual. It is not acceptable that the refrigerant removed from a mobile A/C system, with this equipment, be directly returned to a mobile A/C system. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar CFC-12 (R-12) systems.
Standard

Procedure for Certification that Requirements for Mobile Air Conditioning System Components, Service Equipment, and Service Technician Training Meet SAE J Standards

2012-01-12
HISTORICAL
J2911_201201
This SAE Standard provides manufacturers, testing facilities and providers of technician training with a procedure for certifying compliance with the appropriate standards. Manufacturers who advertise their products as Certified to an SAE J standard shall follow this procedure. Certification of a product is voluntary, however, this certification process is mandatory for those advertising meeting SAE Standard(s) requirements. Only certifying to this standard allows those claiming compliance to advertise that their product (unit), component, or service meets all requirements of the specific SAE standard. Certification of compliance to this and the appropriate standard and use of the SAE label on the product shall only be permitted after all the required information has been submitted to SAE International and it has been posted on the SAE web site.
Standard

Procedure for Certification that Requirements for Mobile Air Conditioning System Components, Service Equipment, and Service Technician Training Meet SAE J Standards

2011-02-04
HISTORICAL
J2911_201102
This SAE Standard provides manufacturers, testing facilities and providers of technician training with a procedure for certifying compliance with the appropriate standards. Manufacturers who advertise their products as Certified to an SAE J standard shall follow this procedure. Certification of a product is voluntary, however, this certification process is mandatory for those advertising meeting SAE Standard(s) requirements. Only certifying to this standard allows those claiming compliance to advertise that their product (unit), component, or service meets all requirements of the specific SAE standard. Certification of compliance to this and the appropriate standard and use of the SAE label on the product shall only be permitted after all the required information has been submitted to SAE International and it has been posted on the SAE web site.
Standard

HFC-134a Refrigerant Electronic Leak Detectors, Minimum Performance Criteria

2008-09-25
HISTORICAL
J2791_200809
This SAE Standard provides testing and functional requirements to meet specified minimum performance criteria for electronic probe-type leak detectors. So they will identify smaller refrigerant leaks when servicing all motor vehicle air conditioning systems, including those engineered with improved sealing and smaller refrigerant charges to address environmental concerns and increase system efficiency. This document does not address any safety issues concerning their design or use.
Standard

Procedure for Certification that Requirements for Mobile Air Conditioning System Components, Service Equipment, and Service Technician Training Meet SAE J Standards

2013-01-14
HISTORICAL
J2911_201301
This SAE Standard provides manufacturers, testing facilities and providers of technician training with a procedure for certifying compliance with the appropriate standards. Manufacturers or seller who advertise their products as Certified to an SAE J standard shall follow this procedure. Certification of a product is voluntary; however, this certification process is mandatory for those advertising meeting SAE Standard(s) requirements. Only certifying to this standard allows those claiming compliance to advertise that their product (unit), component, or service meets all requirements of the specific SAE standard. Certification of compliance to this and the appropriate standard and use of the SAE label on the product shall only be permitted after all the required information has been submitted to SAE International and it has been posted on the SAE web site.
Standard

R134a Mobile Air Conditioning System Leakage Chart

2005-06-08
HISTORICAL
J2727_200506
Current industry standards do not exist for determining refrigerant emissions from mobile air conditioning systems. Test procedures are not common between production component suppliers in establishing leakage values. This “System Leakage Chart” has been developed from industry experience of expected refrigerant leakage gains from system design resulting from technology changes. It provides a rating value of various technologies that are currently available. The “Leakage Chart” can be expanded as new technologies are offered and/or developed. This document provides the information to develop an Excel file template “Leakage Chart” for making system analysis. It is not the intent of this Standard to define the refrigerant emissions from a mobile air conditioning system. It is to only define a system rating based upon the technology used.
Standard

Safety Standards for Motor Vehicle Refrigerant Vapor Compression Systems

2011-02-04
HISTORICAL
J639_201102
This SAE Standard applies to refrigerant vapor compression systems that provide cooling and/or heating for passenger cars, light trucks and commercial vehicles (on and off road) that use automotive type mobile air conditioning (MAC) systems. Large trucks, buses and other vehicles that do not use typical automotive a/c systems or use refrigerants not listed in this document are not covered by this standard. This standard covers any vehicle with a MAC system using a belt or electric motor driven compressor. This document provides standards for design, assembly, test and service of MAC systems to minimize environmental, health and safety impacts. Also included are cautionary statements for the service industry to alert technicians to the inadvisability and possible health or safety effects associated with venting refrigerant during service. It is not intended to restrict the use, or further development, of other types of refrigeration systems for mobile air conditioning applications.
Standard

Safety Standards for Motor Vehicle Refrigerant Vapor Compresssions Systems

2005-06-20
HISTORICAL
J639_200506
This SAE Standard Practice is restricted to refrigerant vapor compression systems that provide cooling and/or heating for the passenger compartment. This document provides design standards for refrigerant containment and safety for these systems. Also included are cautionary statements for the mobile air conditioning service industry to alert service technicians to the inadvisability and the possible health and safety effects associated with venting refrigerant during service. It is not intended to restrict the use, or further development, of other types of refrigeration systems for passenger compartment cooling. Should other systems be found practical, this document may be amended or an additional standard safety practice created for such systems. This document addresses only CFC-12 (R-12), HFC-134a (R-134a), HFC152a (R-152a) a flammable gas and carbon dioxide (R-744) refrigerants.