Refine Your Search

Search Results

Viewing 1 to 12 of 12
Technical Paper

ISS IATCS Coolant Loop Biocide Implementation

2008-06-29
2008-01-2159
The proliferation and growth of microorganisms in the Internal Active Thermal Control System (IATCS) aboard the International Space Station (ISS) has been of significant concern since 2001. Initial testing and assessments of biocides to determine bacterial disinfection capability, material compatibility, stability (rate of oxidative degradation and identification of degradation products), solubility, application methodology, impact on coolant toxicity hazard level, and impact on environmental control and life support systems identified a prioritized list of acceptable biocidal agents including glutaraldehyde, ortho-phthalaldehyde (OPA), and methyl isothiazolone. Glutaraldehyde at greater than 25 ppm was eliminated due to NASA concerns with safety and toxicity and methyl isothiazolone was eliminated from further consideration due to ineffectiveness against biofilms and toxicity at higher concentrations.
Technical Paper

Status of the Orion Environmental Control and Life Support Architecture

2008-06-29
2008-01-2085
In 2007, the architecture of the Orion Environmental Control and Life Support System went through a major reassessment driven by overall vehicle weight considerations. The changes were initiated with the challenge to switch from a two fault tolerant based configuration to one that is one fault tolerant. This paper describes this design evolution.
Technical Paper

Liquid Cooling Garment Adaptation to Enhance Surgical Outcomes

2003-07-07
2003-01-2339
Hypothermia is a well documented problem for surgical patients and is historically addressed by the use of a variety of warming aids and devices applied to the patient before, during, and after surgery. Their effectiveness is limited in many surgeries by practical constraints of surgical access, and hypothermia remains a significant concern. Increasing the temperature of the operating room has been proposed as an alternative solution. However, operating room temperatures must be cool enough to limit thermal stress on the surgical team despite the heat transport barriers imposed by protective sterile garments. Space technology in the form of the liquid cooling garment worn by EVA astronauts answers this need. Hamilton Sundstrand Space Systems International (HSSSI) has been working with Hartford Hospital to adapt liquid cooling garment technology for use by surgical teams in order to allow them to work comfortably in warmer operating room environments.
Technical Paper

Advanced, Lightweight, Space Suit Primary Life Support System for Mars Exploration

2001-07-09
2001-01-2167
Hamilton Sundstrand Space Systems International (HSSSI) has been conducting an internal research and development study of an integrated portable life support system design for advanced exploration missions. This design combines several new subsystem and component concepts to achieve dramatic reductions in system weight and consumables and increased reliability and safety. The study includes the design and manufacture of subsystems and components and the assembly and test of an integrated bench top system prototype. The system design and the results of testing and analysis are described.
Technical Paper

Development of a Membrane Based Gas-Liquid Separator for the Space Station Water Processor

2001-07-09
2001-01-2357
The Water Processor developed for the International Space Station includes a high temperature catalytic reactor that utilizes oxygen gas to oxidize dissolved chemicals. The effluent from the reactor is a mixture of gases (O2, CO2, N2) and hot water. Since the crew has requested that drinking water does not contain any free gas at body temperature (37.8 °C or 100 °F), a phase separator operating at elevated temperatures is required downstream of the catalytic reactor. For this application, Hamilton Sundstrand Space Systems International (HSSSI) has developed a passive Gas Liquid Separator (GLS) that relies on a positive barrier - a membrane - to extract the free gas from the inlet two-phase mixture. The membrane selected is a hollow fiber hydrophobic asymmetric membrane with pore size in the ultra-filtration range. This paper outlines the challenges in both design and operation that were overcome during the development of this device.
Technical Paper

Design and Operation of a Low Pressure Electrolyzer (LPE) for Submarine Applications

2001-07-09
2001-01-2441
A Low Pressure Electrolyzer (LPE) is being developed to provide metabolic oxygen aboard US nuclear submarines. The system is derived from a more complex system already developed for the Virginia Class of attack submarines. The LPE generates up to 250 standard cubic feet per hour (SCFH) of oxygen at ambient pressure through electrolysis of water utilizing SPE® (Solid Polymer Electrolyte) technology. The hydrogen is generated at pressures suitable for disposal overboard. The system operates unattended which minimizes crew workload, and can safely shut down without crew intervention. Generating oxygen at ambient pressure significantly reduces risk to personnel and greatly simplifies the system. Reliability, maintainability, safety, and ease of operation are major system design drivers.
Technical Paper

Investigation of Extravehicular Activity Requirements and Techniques at an Arctic Mars Analog Field Science Base

2001-07-09
2001-01-2199
Designing an EVA system for Mars’s exploration will require a thorough understanding of the mission. Data are available from NASA mission studies, preliminary EVA requirements document, and Apollo program experience. However, additional relevant field experience is required to complete the picture. NASA has addressed this through field tests using prototype EVA equipment and field science programs like the Haughton Mars Project on Devon Island. There, a group of scientists conducts scientific exploration in and around an impact crater in a polar desert similar to expected exploration sites on Mars. Hamilton Sundstrand Space Systems Intl. (HSSSI) EVA system engineers participated in the summer 2000 field research program to gain firsthand knowledge of field science activities. By using a Mars EVA system mockup, they were also able to conduct experiments on EVA system impacts on field science tasks. This field experience and some of its results are described in this paper.
Technical Paper

Performance Testing of a New Membrane Evaporator for the Thermoelectric Integrated Membrane Evaporator System (TIMES) Water Processor

2002-07-15
2002-01-2525
The TIMES system was evaluated to determine its ability to process reverse osmosis (RO) brine as one of the Advanced Water Processor steps. Since preliminary testing performed in 1998 showed that the membrane typically used in the process (Nafion 117) offered a very poor ammonia rejection, a search for an alternate membrane exhibiting high ammonia rejection capability was initiated under NASA-JSC funding. This investigation has resulted in the selection of a PolyVinylAlcohol (PVA) composite membrane as a replacement. When processing RO brine and untreated human urine as feeds, the Pervap 2201 membrane showed a 96% ammonia rejection over a large range of ammonia concentration. The water permeation rates in both laboratory-scale and pilot scale testings were also similar to the Nafion. The water permeance of the Pervap 2201 was approximately 7.5 kg/h/m2/atm (1.1 lb/h/m2/psi).
Technical Paper

Sabatier CO2 Reduction System Design Status

2002-07-15
2002-01-2531
Carbon dioxide reduction in a closed loop life support system recovers water from otherwise waste carbon dioxide and hydrogen. Incorporation of a carbon dioxide reduction assembly (CRA) into the International Space Station life support system frees up thousands of pounds of payload capacity in the supporting Space Shuttle that would otherwise be required to transport water. Achievement of this water recovery goal requires coordination of the CRA design to work within the existing framework of the interface systems that are either already on orbit or well advanced in their development; namely, the Oxygen Generator Assembly (OGA), Carbon Dioxide Removal Assembly (CDRA) and Water Processor Assembly (WPA). The Oxygen Generation System (OGS) rack is in its final design phase and is scarred to accept later installation of the CRA.
Technical Paper

Development Status of ISS Water Processor Assembly

2002-07-15
2002-01-2363
Hamilton Sundstrand Space Systems International, Inc. (HSSSI) is under contract to NASA Marshall Space Flight Center (MSFC) to develop a Water Processor Assembly (WPA) for the International Space Station (ISS). The WPA produces potable quality water from humidity condensate, carbon dioxide reduction water, water obtained from fuel cells, reclaimed urine distillate, shower, handwash and oral hygiene wastewaters. All planned development testing has been completed and this paper provides the status of the development activities and results for the WPA.
Technical Paper

International Space Station Waste Collector Subsystem Risk Mitigation Experiment Design Improvements

2002-07-15
2002-01-2304
The International Space Station Waste Collector Subsystem Risk Mitigation Experiment (ISS WCS RME) was flown as the primary (Shuttle) WCS on Space Shuttle flight STS-104 (ISS-7A) in July 2001, to validate new design enhancements. In general, the WCS is utilized for collecting, storing, and compacting fecal & associated personal hygiene waste, in a zero gravity environment. In addition, the WCS collects and transfers urine to the Shuttle waste storage tank. All functions are executed while controlling odors and providing crew comfort. The ISS WCS previously flew on three Shuttle flights as the Extended Duration Orbiter (EDO) WCS, as it was originally designed to support extended duration Space Shuttle flights up to 30 days in length. Soon after its third flight, the Space Shuttle Program decided to no longer require 30 day extended mission duration capability and provided the EDO WCS to the ISS Program.
Technical Paper

Development of a Miniaturized High Intensity Cryogenic Flow Boiler

2002-07-15
2002-01-2408
An extremely compact heat exchanger is being developed which can boil cryogenic fluids with a liquid heat source at temperatures close to its freezing point. Freezing of the heat source fluid, e.g. water is precluded by the normal flow arrangement. Boiling and superheating of the cryogen occurs as the fluid approaches the heat source in a stack of bonded jet-array laminations. This heat exchanger technology is important in many applications where the storage of fluids at cryogenic temperatures offers substantial advantages in terms of system weight and volume. Often, as in several advanced portable life support system concepts, the advantages include the use of the cryogen as a heat sink in system thermal management. Realizing this benefit and safely conditioning the stored fluid for use requires effective heat transfer between the cryogen and a secondary heat transport fluid.