Influence of Distributing Channel Configuration and Geometric Parameters on Flow Uniformity in Straight Flow-Field of PEM Fuel Cell

2020-04-14
2020-01-1173
Gas distribution of proton exchange membrane fuel cells (PEMFCs) is mainly decided by flow field of bipolar plate. The improper design of distributing channel, nonuniform gas flow distribution and current density distribution among different straight channels are the leading factors that could tremendously undermine the performance and life expectancy of the cell. However, there is lack of research focusing on distributing channel in straight-parallel flow field. In this work, a three-dimensional numerical model of PEMFC cathode flow field is developed with CFD method to investigate the effects of configuration type and width of the distributing channel on pressure distribution in distributing channel and on reactant flow distribution, pressure drop and concentration distribution in multiple straight channel. Effects of electrochemical reaction and formation of water on the flow distribution are taken into consideration.
Technical Paper

Study on the Performance-Determining Factors of Commercially Available MEA in PEMFCs

2020-04-14
2020-01-1171
Proton exchange membrane fuel cells (PEMFC), which convert the chemical energy into electrical energy directly through electrochemical reactions, are widely considered as one of the best power sources for new energy vehicles (NEV). Some of the major advantages of a PEMFC include high power density, high energy conversion efficiency, minimum pollution, low noise, fast startup and low operating temperature. The Membrane Electrode Assembly (MEA) is one of the core components of fuel cells, which composes catalyst layers (CL) coated proton exchange membrane (PEM) and gas diffusion layers (GDL). The performance of MEA is closely related to mass transportation and the rate of electrochemical reaction. The MEA plays a key role not only in the performance of the PEMFCs, but also for the reducing the cost of the fuel cells, as well as accelerating the commercial applications. Commercialized large-size MEA directly plays a major role in determining fuel cell stack and vehicle performance.
Technical Paper

State-of-the-Art and Development Trends of Assembly Technologies for Proton Exchange Membrane Fuel Cell Stack: A Review

2020-04-14
2020-01-1175
Proton Exchange Membrane Fuel Cell (PEMFC) uses hydrogen and oxygen for fuel, the whole energy conversion process almost has no negative impact on the environment. The PEM fuel cell stack with the advantages of low-operating temperature, high current density and fast start-up ability is considered to be the next generation of new electric vehicle power. However, due to the limited current output, it is difficult for a single cell to meet the practical application requirements. The actual fuel cell stack is formed by many single cells assembled together. The assembly process is often related to load transfer, material transfer, energy exchange, multi-phase flow, electrochemical reaction and other factors. The performance of MEA (Membrane Electrode Assembly), sealing gaskets and other components will change during the assembly process, which makes the fuel cell stack assembly process more complex.
Journal Article

Numerical Models for PEMFC Cold Start: A Review

2017-03-28
2017-01-1182
Startup from subzero temperature is one of the major challenges for polymer electrolyte membrane fuel cell (PEMFC) to realize commercialization. Below the freezing point (0°C), water will freeze easily, which blocks the reactant gases into the reaction sites, thus leading to the start failure and material degradation. Therefore, for PEMFC in vehicle application, finding suitable ways to reach successful startup from subfreezing environment is a prerequisite. As it’s difficult and complex for experimental studies to measure the internal quantities, mathematical models are the effective ways to study the detailed transport process and physical phenomenon, which make it possible to achieve detailed prediction of the inner life of the cell. However, review papers only on cold start numerical models are not available. In this study, an extensive review on cold start models is summarized featuring the states and phase changes of water, heat and mass transfer.
Technical Paper

Parameter Identification for a Proton Exchange Membrane Fuel Cell Model

2020-04-14
2020-01-0858
The proton exchange membrane fuel cell (PEMFC) system has emerged as the state-of-art power source for the electric vehicle, but the widespread commercial application of fuel cell vehicle is restricted by its short service life. An enabling high accuracy model holds the key for better understanding, simulation, analysis, subsystem control of the fuel cell system to extract full power and prolong the lifespan. In this paper, a quasi-dynamic lumped parameters model for a 3kW stack is introduced, which includes filling-and-emptying volume sub-models for the relationships between periphery signals and internal states, static water transferring sub-model for the membrane, and empirical electrochemical sub-model for the voltage response. Several dynamic experiments are carried out to identify unknown parameters of the model.
Technical Paper

A Progress Review on Heating Methods and Influence Factors of Cold Start for Automotive PEMFC System

2020-04-14
2020-01-0852
Fuel cell vehicles (FCV) have become a promising transportation tool because of their high efficiency, fast response and zero-emission. However, the cold start problem is one of the main obstacles to limit the further commercialization of FCV in cold weather countries. Many efforts have made to improve the cold start ability. This review presents comprehensive heating methods and influence factors of the research progress in solving the Proton Exchange Membrane Fuel Cells (PEMFC) system cold start problems with more than 100 patents, papers and reports, which may do some help for PEMFC system cold start from the point of practical utilization. Firstly, recent achievements and goals will be summarized in the introduction part. Then, regarding the heating strategies for the PEMFC system cold start, different heating solutions are classified into self-heating strategies and auxiliary-heating heating depending on their heating sources providing approach.
Technical Paper

Investigation of the Operating Conditions on the Water and Thermal Management for a Polymer Electrolyte Membrane Fuel Cell by One-Dimensional Model

2020-04-14
2020-01-0856
Water and thermal management is an essential issue that influences performance and durability of a polymer electrolyte membrane fuel cell (PEMFC). Water content in membrane decides its ionic conductivity and membrane swelling favors the ionic conductivity, resulting in decreases in the membrane’s ohmic resistance and improvement in the output voltage. However, if excessive liquid water can’t be removed out of cell quickly, it will fill in the pores of catalyst layer (CL) and gas diffusion layer (GDL) then flooding may occur. It is essential to keep the water content in membrane at a proper level. In this work, a transient isothermal one-dimensional model is developed to investigate effects of the relative humidity of inlet gas and cell temperature on performance of a PEMFC.
Technical Paper

Development of Online Fuel Cell High Frequency Resistance Monitor Controller

2020-04-14
2020-01-1177
Proton exchange membrane fuel cell (PEMFC) system is expected to be the next generation vehicle powertrain. However, water management is still the main problem which directly affects the performance, reliability and durability in PEMFC system. To ensure the accurate water content estimation, High Frequency Resistance (HFR) is the most representative indicator in laboratory. The HFR is calculated by detecting the Alternating Current (AC) voltage response of fuel cell under the excitation of 1k Hz AC current. The voltage level of the AC excitation affects the measurement of HFR. Generally, 5mV AC excitation is used to measure HFR for the fuel cell with an output voltage between 0.6-1V. So, online HFR monitor is a big challenge for vehicle application, due to its low Signal/Noise Ratio (S/N), poor Electromagnetic Compatibility (EMC) environment, high common mode voltage and several hundred cells. In this work, an online fuel cell HFR monitor controller is developed.
Technical Paper

Dynamic-Static Optimization Design with Uncertain Parameters for Lift Arm of Parking Robot

2020-04-14
2020-01-0511
There are a large number of uncertainties in engineering design, and the accumulated uncertainties will enlarge the overall failure probability of the structure system. Therefore, structural design considering uncertainties has good guiding significance for improving the reliability of engineering structures. To address this issue, the dynamic-static structural topology optimization is established and reliability-based topology optimization with decoupling format is conducted in this study. The design point which satisfying the constraint of the target reliability indicator is obtained according to the reliability indicators of the first-order reliability method, and the uncertain design variables are modified into a deterministic variable according to the sensitivity information.
Journal Article

The Effect of Fixture on the Testing Accuracy in the Spindle-Coupled Road Simulation Test

2018-04-03
2018-01-0130
The action of load on the component is crucial to evaluate the performance of durability. Another factor that affects fatigue life is the boundary conditions of the test specimen being tested by introducing unrealistic loads on the component of interest. The physical test is widely conducted in the laboratory. The fixture provides additional constraints on the test specimen as well as reaction forces to balance the test system [1]. The characteristics of the fixture involved in the test is important to analyze and assess the test results [2]. The impact of the reaction force of the fixture on the spindle-coupled axle road simulation test is presented in this article. A simplified 7-DoF (degrees of freedom) model is introduced to demonstrate the dynamic behavior of the vehicle. The influence on the internal load by the fixture has been analyzed. Followed by a more detailed MBS (multibodysystem) model to give a thorough understanding of the phenomenon.
Technical Paper

Elementary Investigation into Road Simulation Experiment of Powertrain and Components of Fuel Cell Passenger Car

2008-06-23
2008-01-1585
It is very important to investigate how road irregularity excitation will affect the durability, reliability, and performance degradation of fuel cell vehicle powertrain and its key components, including the electric motor, power control unit, power battery package and fuel cell engine system. There are very few published literatures in this research area. In this paper, an elementary but integrated experimental work is described, including the real road load sample on proving ground, road load reproduction on vibration test rig, total vehicle road simulation test and key components vibration tests. Remote parameter control technology is adopted to reproduce the real road load on road simulator and six-degree-of-freedom vibration table, which is used respectively for total vehicle and components vibration tests.
Technical Paper

Effect of Road-Induced Vibration on Gas-Tightness of Vehicular Fuel Cell Stack

2016-04-05
2016-01-1186
The vehicular fuel cell stack is unavoidably impacted by the vibration in the real-world usage due to the road unevenness. However, effects of vibration on stacks have yet to be completely understood. In this work, the mechanical integrity and gas-tightness of the stack were investigated through a strengthen road vibration test with a duration of 200 h. The excitation signals applied in the vibration test were simulated by the acceleration of the stack, which were previously measured in a vehicle vibration test. The load signals of the vehicle vibration test were iterated through a road simulator from vehicle acceleration signals which were originally sampled in the proving ground. Frequency sweep test was conducted before and after the vibration test. During the vibration test, mechanical structure inspection and pressure maintaining test of the stack were conducted at regular intervals.
Technical Paper

Analysis under Vehicle-Pedalcyclist Risk Scenario Based on Comparison between Real Accident and Naturalistic Driving Data

2018-04-03
2018-01-1048
This paper constructs the Accident Crash Scenarios(ACSs) classification system based on the traffic accident data collected by the traffic management department in a Chinses city from 2013 to 2015. The classification system selects four influenced variables on the basis of Critical Driving Scenarios(CDSs) in Naturalistic Driving Data. The proportions of each variable are analyzed, and all ACSs are divided into 48 scenarios. The highest proportion of nine ACSs are extracted from all 10596 ACSs, and the result shows the ACSs involved Car-Pedalcyclist occupy the top four scenarios, and the scenarios involved intersection situations are worth attention. Pedalcyclists include bicyclists, motorcyclists, tri-cyclists and electric bicyclists. Multivariate Logistic Regression(MLR) analysis is then used to study the ACSs involved the type of Car-Pedalcyclist.
Technical Paper

Instantaneous Optimization Energy Management for Extended-Range Electric Vehicle Based on Minimum Loss Power Algorithm

2013-09-08
2013-24-0073
Most of the existing energy management strategies for Extended-Range Electric Vehicles (E-REVs) are heuristic, which restricts coordination between the battery and the Range Extender. This paper presents an instantaneous optimization energy management strategy based on the Minimum Loss Power Algorithm (MLPA) for a fuel cell E-REV. An instantaneous loss power function of power train system is constructed by considering the charge and discharge efficiency of the battery, together with the working efficiency of the fuel cell Range Extender. The battery working mode and operating points of the fuel cell Range Extender are decided by an instantaneous optimization module (an artificial neural network) that aims to minimize the loss power function at each time step.
Technical Paper

Investigation of PEM Fuel Cell Degradation Under On-Off Cyclic Condition

2021-12-31
2021-01-7022
Proton exchange membrane fuel cell (PEMFC) has attracted extensive attention in recent years because of its high efficiency and zero emission. Although fuel cell technology has made great progress, durability is still the bottleneck of its large-scale commercialization. In order to systematically study the degradation of fuel cell system for transportation applications, we selected the most severe operating condition - on-off cyclic condition as the research object, and focused on the influence of cell temperature and air relative humidity on the degradation rate of fuel cell by means of polarization curve, reference voltage and CV. The results show that with the same temperature, the fuel cell performance degradation rate first decreases and then increases with the decrease of humidity, which may be due to the increase of platinum ion transfer rate at high relative humidity and the dry membrane at low relative humidity.
Technical Paper

Network Delay Modelling and Optimization of Internet-Based Distributed Test Platform for Fuel Cell Electric Vehicle Powertrain System

2021-12-15
2021-01-7026
The accelerated global progress in the research and development of automobile products, and the use of new technologies, such as the Internet, cloud computing and big data, to coordinate development platforms in different regions and fields, can reduce the duration and cost of development and testing. Specifically, in the context of the current coronavirus disease (COVID-19) pandemic, which has caused great obstacles to normal logistics and transportation, personnel exchanges and information communication, platforms that can support global operation are significant for product testing and validation, because they eliminate the need for the transportation of personnel and equipment. Therefore, the establishment of a distributed test and validation platform for automotive powertrain systems, which can integrate software and hardware testing, is important in terms of both scientific research and industrialization.
Technical Paper

Numerical Study of Gas Purge in Proton Exchange Membrane Fuel Cell

2021-12-31
2021-01-7005
A three-dimensional two-phase single-channel purge mode of proton exchange membrane fuel cell was established, and the steady-state and purge process were simulated. The water distribution in fuel cell after steady-state operation was studied. The changing trend of water content and water volume fraction under co-flow/counter-flow purge conditions was also studied. The results show that the membrane water content and water volume fraction under the ridge position of the fuel cell is more than the flow channel. The non-uniform distribution of membrane water along the direction of the flow channel is significant in co-flow, and the difference can be up to 6. In addition, the effects of different working conditions on purge were studied. It was found that in the purge condition, the water content of the inner membrane of 120s could be basically reduced to below 3.
Technical Paper

Dynamic Durability Prediction of Fuel Cells Using Long Short-Term Memory Neural Network

2022-03-29
2022-01-0687
Durability performance prediction is a critical issue in fuel cell research. During the demonstration operation of fuel cell commercial vehicles in China, this issue has attracted more attention. In this article, the long short-term memory neural network (LSTMNN), which is an improved recurrent neural network (RNN), and the demonstration operation data are used to establish the prediction model to predict the durability performance of the fuel cell stack. Then, a model based on a back-propagation neural network (BPNN) is established to be a control group. The demonstration operation data is divided into training group and validation group. The former is used to train the prediction model, and the latter is used to verify the validity and accuracy of the prediction model. The outputs of the prediction model, as the durability performance evaluation indexes of the fuel cell, are the polarization curve (current-voltage curve) and the voltage decay curve (time-voltage curve).
Technical Paper

Acoustic and Aerodynamic Performances of One Phononic Crystal Duct with Periodic Mufflers

2023-04-11
2023-01-0433
The acoustic muffler is one of the practical solutions to reduce the noise in ducts. The acoustic and aerodynamic performances are two critical indices of one muffler for the air intake system of a hydrogen fuel cell electric vehicle (FCEV). In this study, the concept of phononic crystal is applied to design the muffler to obtain superior acoustic performance. One duct with periodic and compact resonator-type mufflers is designed for broadband noise attenuation. The two-dimensional (2D) transfer matrix method and bandgap theory are employed to calculate the transmission loss (TL) and acoustic bandgap. It is numerically and theoretically demonstrated that broadband noise attenuation could be acquired from 500Hz to 3500Hz. Afterwards, the three-dimensional (3D) computational fluid dynamics (CFD) approach is applied to predict the pressure distribution. The results indicate that the proposed hybrid muffler and the phononic crystal duct possess low pressure loss values.
Technical Paper

Understanding the Transient Behavior and Consistency Evolution of PEMFC from the Perspective of Temperature

2022-03-29
2022-01-0189
The temperature of proton exchange membrane fuel cell (PEMFC) is the key factor restricting fuel cell’s performance. A deep understanding of temperature on stack voltage consistency and transient characteristics is necessary for improving the output performance of fuel cell. In this paper, the variation trend of consistency and transient characteristics of 20kW PEMFC stack at different temperatures is studied by experiment. In consistency, the amplitude of voltage changes and voltage difference (voltage coefficient variation σV) under different thermal loading conditions is examined. In transient characteristics, discussing the trends of transient voltage at different thermal loading. As the result, once the stack temperature increases from 65 °C to 70 °C, the stack performance and dynamic response are significantly improved, which may be caused by the rise in temperature promoting the establishment of the internal quality transmission channel.