Refine Your Search

Search Results

Viewing 1 to 8 of 8
Journal Article

Comparison of the THOR and Hybrid III Responses in Oblique Impacts

2014-04-01
2014-01-0559
NHTSA has been investigating a new test mode in which a research moving deformable barrier (RMDB) impacts a stationary vehicle at 90.1 kph, a 15 degree angle, and a 35% vehicle overlap. The test utilizes the THOR NT with modification kit (THOR) dummy positioned in both the driver and passenger seats. This paper compares the behavior of the THOR and Hybrid III dummies during this oblique research test mode. A series of four full vehicle oblique impact crash tests were performed. Two tests were equipped with THOR dummies and two tests were equipped with Hybrid III dummies. All dummies represent 50th percentile males and were positioned in the vehicle according to the FMVSS208 procedure. The Hybrid III dummies were instrumented with the Nine Accelerometer Package (NAP) to calculate brain injury criteria (BrIC) as well as THOR-Lx lower legs. Injury responses were recorded for each dummy during the event. High speed cameras were used to capture vehicle and dummy kinematics.
Technical Paper

Assessment of the Thor and Hybrid III Crash Dummies: Steering Wheel Rim Impacts to the Upper Abdomen

2004-03-08
2004-01-0310
This investigation explored THOR's force-deflection response to upper abdomen/lower ribcage steering wheel rim impacts in comparison to the Hybrid III and cadaver test subjects. The stationary subjects were impacted by a ballasted surrogate wheel propelled at 4 m/s, a test condition designed to approximate the upper abdomen impacting a steering wheel rim in a frontal crash. Both the standard THOR and the Hybrid III crash dummies were substantially stiffer than the cadavers. Removing THOR's torso skin and foam from the upper abdomen and replacing the standard Hybrid III abdomen with a prototype gel-filled unit produced force-deflection results that were more similar to the cadavers. THOR offers advantages over the Hybrid III because of its ability to measure abdominal deflection. THOR, with modification, would be a useful instrument with which to assess the crashworthiness of steering assemblies and restraint systems in frontal crashes.
Technical Paper

Frequency Content Analysis and Filter Class Selection for the Small Female Instrumented Upper Extremity

2002-03-04
2002-01-0806
Although filter class specifications have been defined for most anthropomorphic test devices, no recommendation exists for the instrumented upper extremity. A three-part study was performed to determine the best channel filter class (CFC) to use for the instrumented upper extremity. By analyzing frequency content of signals from accelerometers and load cells, filtering data through three of the four possible CFC's to compare effects on the signals, and performing an injury comparison between cadaver data and the filtered load cell data, CFC 600 was chosen and recommended as the optimum filter class to use for upper extremity testing.
Technical Paper

Comparison of Belted Hybrid III, THOR, and Cadaver Thoracic Responses in Oblique Frontal and Full Frontal Sled Tests

2003-03-03
2003-01-0160
This paper compares restrained Hybrid III and THOR thoracic kinematics and cadaver injury outcome in 30° oblique frontal and in full frontal sled tests. Peak shoulder belt tension, the primary source of chest loading, changed by less than four percent and peak chest resultant acceleration changed by less than 10% over the 30° range tested. Thoracic kinematics were likewise insensitive to the direction of the collision vector, though they were markedly different between the two dummies. Mid-sternal Hybrid III chest deflection, measured by the standard sternal potentiometer and by supplemental internal string potentiometers, was slightly lower (∼10%) in the oblique tests, but the oblique tests produced a negligible increase in lateral movement of the sternum. In an attempt to understand the biofidelity of these dummy responses, a series of 30-km/h human cadaver tests having several collision vectors (0°, 15°, 30°, 45°) was analyzed.
Technical Paper

Kinematic Analysis of Head/Neck Motion in Pedestrian-Vehicle Collisions Using 6-Degree-of-Freedom Instrumentation Cubes

2006-04-03
2006-01-0681
Given the quantity and severity of head injuries to pedestrians in vehicle-to-pedestrian collisions, human pedestrian finite element models and pedestrian dummies must possess a biofidelic head/neck response to accurately reproduce head-strike kinematics and kinetics. Full-scale pedestrian impact experiments were performed on post-mortem human surrogates (PMHS) using a mid-sized sport utility vehicle and a small sedan. Kinematics of the head and torso were obtained with a six-degree-of-freedom (6DOF) cube, which contained three orthogonally mounted linear accelerometers and three angular rate sensors. The goal of the current study was to present a methodology for analyzing the data obtained from the sensors on each cube, and to use the kinematics data to calculate spatial trajectories, as well as linear velocities and angular accelerations of the head and T1 vertebra.
Technical Paper

The Influence of Pelvis Design on the Lateral Pelvic Impact Response of the Polar-II Pedestrian Dummy

2006-04-03
2006-01-0682
Previous studies utilizing the Polar-II pedestrian dummy have suggested the need for a more biofidelic pelvis design in order to improve the overall dummy response kinematics. The current Polar-II dummy pelvis is a rigid steel structure. A preliminary version of a modified deformable pelvis equipped with sensors for measuring internal deflection and load has been designed. The goal of this study was to assess the biofidelity of these two pelves in full-scale tests with the Polar-II dummy that mimic lateral pelvic impact tests on PMHS (post-mortem human subjects) reported in the literature. The force - time, deflection - time, and force - deflection histories were compared to new PMHS response corridors determined using a normalization technique. In all tests with both pelves, the initial response (i.e., the first 3 ms to 5 ms following initial dummy - impactor contact) appeared to be totally determined by the mechanical behavior of the flesh.
Technical Paper

Elimination of Thoracic Muscle Tensing Effects for Frontal Crash Dummies

2005-04-11
2005-01-0307
Current crash dummy biofidelity standards include the estimated effects of tensing the muscles of the thorax. This study reviewed the decision to incorporate muscle tensing by examining relevant past studies and by using an existing mathematical model of thoracic impacts. The study finds evidence that muscle tensing effects are less pronounced than implied by the biofidelity standard response corridors, that the response corridors were improperly modified to include tensing effects, and that tensing of other body regions, such as extremity bracing, may have a much greater effect on the response and injury potential than tensing of only the thoracic musculature. Based on these findings, it is recommended that muscle tensing should be eliminated from thoracic biofidelity requirements until there is sufficient information regarding multi-region muscle tensing response and the capability to incorporate this new data into a crash dummy.
Technical Paper

The Utility of Hybrid III and THOR Chest Deflection for Discriminating Between Standard and Force-Limiting Belt Systems

2003-10-27
2003-22-0013
Recent field data studies have shown that force-limiting belt systems reduce the occurrence of thoracic injuries in frontal crashes relative to standard (not force-limiting) belt systems. Laboratory cadaver tests have also shown reductions in trauma, as well as in chest deflection, associated with a force-limiting belt. On the other hand, tests using anthropomorphic test devices (ATDs) have shown trends indicating increased, decreased, or unchanged chest deflection. This paper attempts to resolve previous experimental studies by comparing the anterior-posterior and lateral chest deflections measured by the THOR and Hybrid III (H-III) dummies over a range of experimental conditions. The analysis involves nineteen 48-km/h and 57-km/h sled tests utilizing force-limiting and standard seat belt systems, both with an air bag. Tests on both the driver side and the passenger side are considered.
X