Refine Your Search

Topic

Author

Search Results

Journal Article

A Computational Study of Rear-Facing and Forward-Facing Child Restraints

2008-04-14
2008-01-1233
A recent study of U.S. crash data has shown that children 0-23 months of age in forward-facing child restraint systems (FFCRS) are 76% more likely to be seriously injured in comparison to children in rear-facing child restraint systems (RFCRS). Motivated by the epidemiological data, seven sled tests of dummies in child seats were performed at the University of Virginia using a crash pulse similar to FMVSS 213 test conditions. The tests showed an advantage for RFCRS; however, real-world crashes include a great deal of variability among factors that may affect the relative performance of FFCRS and RFCRS. Therefore, this research developed MADYMO computational models of these tests and varied several real-world parameters. These models used ellipsoid models of Q-series child dummies and facet surface models of American- and Swedish- style convertible child restraints (CRS).
Technical Paper

A Madymo Model of the Foot and Leg for Local Impacts

1999-10-10
99SC12
It has been reported that lower extremity injuries represent a measurable portion of all moderate-to-severe automobile crash- related injuries. Thus, a simple tool to assist with the design of leg and foot injury countermeasures is desirable. The objective of this study is to develop a mathematical model which can predict load propagation and kinematics of the foot and leg in frontal automotive impacts. A multi-body model developed at the University of Virginia and validated for blunt impact to the whole foot has been used as basis for the current work. This model includes representations of the tibia, fibula, talus, hindfoot, midfoot and forefoot bones. Additionally, the model provides a means for tensioning the Achilles tendon. In the current study, the simulations conducted correspond to tests performed by the Transport Research Laboratory and the University of Nottingham on knee-amputated cadaver specimens.
Technical Paper

A Method for the Experimental Investigation of Acceleration as a Mechanism of Aortic Injury

2005-04-11
2005-01-0295
Rupture of the thoracic aorta is a leading cause of rapid fatality in automobile crashes, but the mechanism of this injury remains unknown. One commonly postulated mechanism is a differential motion of the aortic arch relative to the heart and its neighboring vessels caused by high-magnitude acceleration of the thorax. Recent Indy car crash data show, however, that humans can withstand accelerations exceeding 100 g with no injury to the thoracic vasculature. This paper presents a method to investigate the efficacy of acceleration as an aortic injury mechanism using high-acceleration, low chest deflection sled tests. The repeatability and predictability of the test method was evaluated using two Hybrid III tests and two tests with cadaver subjects. The cadaver tests resulted in sustained mid-spine accelerations of up to 80 g for 20 ms with peak mid-spine accelerations of up to 175 g, and maximum chest deflections lower than 11% of the total chest depth.
Technical Paper

A Sensor Suite for Toeboard Three-Dimensional Deformation Measurement During Crash

2020-03-31
2019-22-0014
This paper presents the development of a sensor suite that is used to measure the toeboard threedimensional (3D) dynamic deformation during a crash test, along with the methodology to use the sensor suite for toeboard measurement. The sensor suite consists of three high-speed cameras, which are firmly connected through a rigid metal frame. Two cameras, facing directly towards the toeboard, measure the shape of the toeboard through stereovision. The third camera, facing the ground, is equipped with a three-axis gyroscope and a three-axis accelerometer and localizes the sensor suite globally for removing the vibration of the sensor suite. The sensor suite was mounted onto the car through car seat mounting bolt holes, and a hole was made on the floor to let the downward camera see the ground. A pipeline using the data collected by the sensor suite is also introduced in this paper.
Technical Paper

A Simulation-Based Calibration and Sensitivity Analysis of a Finite Element Model of THOR Head-Neck Complex

2011-04-12
2011-01-1123
The THOR-NT dummy has been developed and continuously improved by NHTSA to provide automotive manufacturers an advanced tool that can be used to assess the injury risk of vehicle occupants in crash tests. With the recent improvements of finite element (FE) technology and the increase of computational power, a validated FE model of THOR may provide an efficient tool for the design optimization of vehicles and their restraint systems. The main goal of this study was to improve biofidelity of a head-neck FE model of THOR-NT dummy. A three-dimensional FE model of the head and neck was developed in LS-Dyna based on the drawings of the THOR dummy. The material properties of deformable parts and the joints properties between rigid parts were assigned initially based on data found in the literature, and then calibrated using optimization techniques.
Technical Paper

Analysis of upper extremity response under side air bag loading

2001-06-04
2001-06-0016
Computer simulations, dummy experiments with a new enhanced upper extremity, and small female cadaver experiments were used to analyze the small female upper extremity response under side air bag loading. After establishing the initial position, three tests were performed with the 5th percentile female hybrid III dummy, and six experiments with small female cadaver subjects. A new 5th percentile female enhanced upper extremity was developed for the dummy experiments that included a two-axis wrist load cell in addition to the existing six-axis load cells in both the forearm and humerus. Forearm pronation was also included in the new dummy upper extremity to increase the biofidelity of the interaction with the handgrip. Instrumentation for both the cadaver and dummy tests included accelerometers and magnetohydrodynamic angular rate sensors on the forearm, humerus, upper and lower spine.
Journal Article

Biofidelity of THOR 5th Percentile Female ATD in Ankle Eversion and Inversion

2020-04-14
2020-01-0528
Females have higher frequency and risk of foot and ankle injuries in motor vehicle collisions than similar-sized males. Therefore, lower extremity biofidelity and accurate injury prediction of female ATDs is critical. This paper aims to compare the THOR 5th percentile female (THOR-05F) anthropomorphic test device (ATD) response with male and female PMHS data of various sizes under ankle inversion and eversion. The THOR-05F lower extremity was subjected to dynamic inversion and eversion ankle loading with a constant 2000N axial force applied through the tibia. Twelve THOR-05F tests (3 inversion and 3 eversion on both, left and right legs) were performed with boundary conditions consistent with previous post-mortem human subject (PMHS) lower extremity tests.
Technical Paper

Biomechanical Response and Physical Properties of the Leg, Foot, and Ankle

1996-11-01
962424
The anatomical dimensions, inertial properties, and mechanical responses of cadaver leg, foot, and ankle specimens were evaluated relative to those of human volunteers and current anthropometric test devices. Dummy designs tested included the Hybrid III, Hybrid III with soft joint stops, ALEX I, and the GM/FTSS lower limbs. Static and dynamic tests of the leg, foot, and ankle were conducted at the laboratories of the Renault Biomedical Research Department and the University of Virginia. The inertial and geometric properties of the dummy lower limbs were measured and compared with cadaver properties and published volunteer values. Compression tests of the leg were performed using static and dynamic loading to determine compliance of the foot and ankle. Quasi-static rotational properties for dorsiflexion and inversion/eversion motion were obtained for the dummy, cadaver, and volunteer joints of the hindfoot.
Technical Paper

Blood Flow and Fluid-Structure Interactions in the Human Aorta During Traumatic Rupture Conditions

2007-10-29
2007-22-0010
Traumatic aortic rupture (TAR) accounts for a significant mortality in automobile crashes. A numerical method by means of a mesh-based code coupling is employed to elucidate the injury mechanism of TAR. The aorta is modeled as a single-layered thick wall composed of two families of collagen fibers using an anisotropic strain energy function with consideration of viscoelasticity. A set of constitutive parameters is identified from experimental data of the human aorta, providing strict local convexity. An in vitro aorta model reconstructed from the Visible Human dataset is applied to the pulsatile blood flow to establish the references of mechanical quantities for physiological conditions. A series of simulations is performed using the parameterized impact pulses obtained from frontal sled tests.
Technical Paper

Comparative Evaluation of Dummy Response with Thor-Lx/HIIIr and Hybrid III Lower Extremities

2002-03-04
2002-01-0016
Multiple series of frontal sled tests were performed to evaluate the new Thor-Lx/HIIIr lower extremity developed by the National Highway Traffic Safety Administration for retrofit use on the 50th percentile male Hybrid III. This study's objective was to compare the Thor-Lx/HIIIr to the existing Hybrid III dummy leg (HIII) from the standpoint of repeatability and effects on femur and upper body response values.\ The test-to-test repeatability of the dummy responses, as measured by the coefficient of variation (CV), was generally acceptable (CV < 10%) for all of the test conditions for both legs. Overall, tests with the Thor-Lx/HIIIr legs produced upper body movement and injury criteria values for the head and chest that were acceptably consistent and were generally indistinguishable from those produced with the HIII leg. Low right femur loads, which ranged from 4 to 25 percent of the injury assessment reference value, varied substantially test-to-test for tests with both types of legs.
Technical Paper

Comparison of Kinematic Responses of the Head and Spine for Children and Adults in Low-Speed Frontal Sled Tests

2009-11-02
2009-22-0012
Previous research has suggested that the pediatric ATD spine, developed from scaling the adult ATD spine, may not adequately represent a child's spine and thus may lead to important differences in the ATD head trajectory relative to a human. To gain further insight into this issue, the objectives of this study were, through non-injurious frontal sled tests on human volunteers, to 1) quantify the kinematic responses of the restrained child's head and spine and 2) compare pediatric kinematic responses to those of the adult. Low-speed frontal sled tests were conducted using male human volunteers (20 subjects: 6-14 years old, 10 subjects: 18-40 years old), in which the safety envelope was defined from an amusement park bumper-car impact.
Technical Paper

Cooling Fan Modeling to Support Robust AC/Cooling System Simulation

2005-04-11
2005-01-1905
Advanced design of modern engine cooling and vehicle HVAC components involves sophisticated simulation. In particular, front end air flow models must be able to cover the complete range of conditions from idle to high road speeds involving multiple fans of varying types both powered and unpowered. This paper presents a model for electric radiator cooling fans which covers the complete range of powered and unpowered (freewheel) operation. The model applies equally well to mechanical drive fans.
Technical Paper

Correlation of Strain and Loads Measured in the Long Bones With Observed Kinematics of the Lower Limb During Vehicle-Pedestrian Impacts

2007-10-29
2007-22-0018
The purpose of this study is to determine the loads in the long bones of the lower extremities during vehicle pedestrian impact tests, and to correlate load data with observed kinematics in an effort to understand how stature and vehicle shape influence pedestrian response. In tests with a large sedan and a small multi-purpose vehicle (MPV), four postmortem human surrogates (PMHS) in mid-stance gait were struck laterally at 40 km/h. Prior to the tests, each PMHS was instrumented with four uniaxial strain gages around the mid-shaft cross section of the struck-side (right) tibia and the femora bilaterally. After the tests, the non-fractured bones were harvested and subjected to three-point bending experiments. The effective elastic moduli were determined by relating the applied bending loads with the measured strains using strain gage locations, detailed bone geometry, and elastic beam theory.
Technical Paper

Deployment of Air Bags into the Thorax of an Out-of-Position Dummy

1999-03-01
1999-01-0764
The air bag has proven effective in reducing fatalities in frontal crashes with estimated decreases ranging from 11% to 30% depending on the size of the vehicle [IIHS-1995, Kahane-1996]. At the same time, some air bag designs have caused fatalities when front-seat passengers have been in close proximity to the deploying air bag [Kleinberger-1997]. The objective of this study was to develop an accurate and repeatable out-of-position test fixture to study the deployment of air bags into out-of-position occupants. Tests were performed with a 5th percentile female Hybrid III dummy and studied air bag loading on the thorax using draft ISO-2 out-of-position (OOP) occupant positioning. Two different interpretations of the ISO-2 positioning were used in this study. The first, termed Nominal ISO-2, placed the chin on the steering wheel with the spine parallel to the steering wheel.
Technical Paper

Detached Eddy Simulation on a Swept Hybrid Model in the IRT

2015-06-15
2015-01-2122
In recent years, there has been a growing desire to incorporate computational methods into aircraft icing certification practices. To improve understanding of ice shapes, a new experimental program in the NASA Icing Research Tunnel (IRT) will investigate swept hybrid models which are very large relative to the test section and are intended to operate at high lift coefficients. The present computations were conducted to help plan the experiments and to ascertain any effects of flow separation and unsteady forces. As they can be useful in robustly and accurately predicting large separation regions and capturing flow unsteadiness, a Detached Eddy Simulation (DES) approach has been adopted for simulating the flow over these large high-lift wing sections. The DES methodology was first validated using experimental data from an unswept NACA 0012 airfoil with leading-edge ice accretion, showing reasonable performance.
Journal Article

Development of a Biofidelic Rollover Dummy-Part II: Validation of the Kinematic Response of THOR Multi-Body and Finite Element Models Relative to Response of the Physical THOR Dummy under Laboratory Rollover Conditions

2016-04-05
2016-01-1486
While over 30% of US occupant fatalities occur in rollover crashes, no dummy has been developed for such a condition. Currently, an efficient, cost-effective methodology is being implemented to develop a biofidelic rollover dummy. Instead of designing a rollover dummy from scratch, this methodology identifies a baseline dummy and modifies it to improve its response in a rollover crash. Using computational models of the baseline dummy, including both multibody (MB) and finite element (FE) models, the dummy’s structure is continually modified until its response is aligned (using BioRank/CORA metric) with biofidelity targets. A previous study (Part I) identified the THOR dummy as a suitable baseline dummy by comparing the kinematic responses of six existing dummies with PMHS response corridors through laboratory rollover testing.
Technical Paper

Error Analysis of Curvature-Based Contour Measurement Devices

2000-03-06
2000-01-0054
Curvature-based contour measurement devices with discrete curvature measurement gauges are widely used for the measurement of dynamic thoracic contours in both dummy and cadaveric automobile sled testing. Such devices include the chestband used to determine local thoracic contours at several rib levels for evaluation of injury parameters in dummy and cadaveric subjects. The use of these devices involves integration of local curvatures to obtain position data, and often incorporates several approximations, including a quasi-continuous approximation of discrete measured curvatures. By comparing a reference and a calculated position profile, this study analyzes the error in local positions induced from several sources. The first source of error is the measurement of curvatures at discrete locations, typically with 2.5 - 5.0 cm curvature gauge spacing.
Technical Paper

Evaluation of Biofidelity of Side Impact Computational Surrogates (ES-2re, WorldSID, GHBMC)

2014-04-01
2014-01-0541
The goal of this study was to evaluate the biofidelity of the three computational surrogates (GHBMC model, WorldSID model, and the FTSS ES-2re model) under the side impact rigid wall sled test condition. The responses of the three computational surrogates were compared to those of post mortem human surrogate (PMHS) and objectively evaluated using the correlation and analysis (CORA) rating method. Among the three computational surrogates, the GHBMC model showed the best biofidelity based on the CORA rating score (GHBMC =0.65, WorldSID =0.57, FTSS ES-2re =0.58). In general, the response of the pelvis of all the models showed a good correlation with the PMHS response, while the response of the shoulder and the lower extremity did not. In terms of fracture prediction, the GHBMC model overestimated bone fracture.
Technical Paper

Experimental Devices to Simulate Toepan and Floorpan Intrusion

1997-02-24
970574
Two sled systems capable of producing structural intrusion in the footwell region of an automobile have been developed. The first, System A, provides translational toepan intrusion using actuator pistons to drive the footwell structure of the test buck. These actuator pistons are coupled to the hydraulic decelerator of the test sled and are powered by hydraulic energy from the impact event. Resulting footwell intrusion is characterized using a toepan pulse analogous to the acceleration pulse used to characterize sled and vehicle decelerations. Sled tests with System A indicate that it is capable of accurately and repeatably simulating toepan/floorpan intrusion into the occupant footwell. Test results, including a comparison of lower extremity response between intrusion sled tests and no intrusion sled tests, indicate that this system is capable of repeatable, controlled structural intrusion during a sled test impact.
Technical Paper

Geometrical Personalization of Pedestrian Finite Element Models Using Morphing Increases the Biofidelity of Their Impact Kinematics

2016-04-05
2016-01-1506
Pedestrian finite element models (PFEM) are used to investigate and predict the injury outcomes from vehicle-pedestrian impact. As postmortem human surrogates (PMHS) differ in anthropometry across subjects, it is believed that the biofidelity of PFEM cannot be properly evaluated by comparing a generic anthropometry model against the specific PMHS test data. Global geometric personalization can scale the PFEM geometry to match the height and weight of a specific PMHS, while local geometric personalization via morphing can modify the PFEM geometry to match specific PMHS anatomy. The goal of the current study was to evaluate the benefit of morphed PFEM compared to globally-scaled and generic PFEM by comparing the kinematics against PMHS test results. The AM50 THUMS PFEM (v4.01) was used as a baseline for anthropometry, and personalized PFEM were created to the anthropometric specifications of two obese PMHS used in a previous pedestrian impact study using a mid-size sedan.
X