Refine Your Search

Topic

Search Results

Standard

Low Voltage Primary Cable

2005-12-06
HISTORICAL
J1128_200512
This standard covers low voltage primary cable intended for use at a nominal system voltage of 60 V DC (25 V AC) or less in surface vehicle electrical systems. The tests are intended to qualify cables for normal applications with limited exposure to fluids and physical abuse.
Standard

Low Voltage Primary Cable

2012-10-18
HISTORICAL
J1128_201210
This standard covers low voltage primary cable intended for use at a nominal system voltage of 60 V DC (25 V AC) or less in surface vehicle electrical systems. The tests are intended to qualify cables for normal applications with limited exposure to fluids and physical abuse.
Standard

Low Voltage Primary Cable

2011-01-11
HISTORICAL
J1128_201101
This standard covers low voltage primary cable intended for use at a nominal system voltage of 60 V DC (25 V AC) or less in surface vehicle electrical systems. The tests are intended to qualify cables for normal applications with limited exposure to fluids and physical abuse.
Standard

Low Voltage Primary Cable

2015-12-03
HISTORICAL
J1128_201512
This standard covers low voltage primary cable intended for use at a nominal system voltage of 60 V DC (25 V AC) or less in surface vehicle electrical systems. The tests are intended to qualify cables for normal applications with limited exposure to fluids and physical abuse.
Standard

Low Voltage Primary Cable

2013-10-09
HISTORICAL
J1128_201310
This standard covers low voltage primary cable intended for use at a nominal system voltage of 60 V DC (25 V AC) or less in surface vehicle electrical systems. The tests are intended to qualify cables for normal applications with limited exposure to fluids and physical abuse.
Standard

Low Voltage Primary Cable

2020-12-04
CURRENT
J1128_202012
This SAE Standard covers low voltage primary cable intended for use at a nominal system voltage of 60 VDC (25 VAC) or less in surface vehicle electrical systems. The tests are intended to qualify cables for normal applications with limited exposure to fluids and physical abuse.
Standard

Low Voltage Battery Cable

2015-12-03
HISTORICAL
J1127_201512
This standard covers low voltage battery cable intended for use at a nominal system voltage of 60 V DC (25 V AC) or less in surface vehicle electrical systems. The tests are intended to qualify cables for normal applications with limited exposure to fluids and physical abuse.
Standard

Low Voltage Battery Cable

2020-12-04
CURRENT
J1127_202012
This SAE Standard covers low voltage battery cable intended for use at a nominal system voltage of 60 VDC (25 VAC) or less in surface vehicle electrical systems. The tests are intended to qualify cables for normal applications with limited exposure to fluids and physical abuse.
Standard

Low Voltage Battery Cable

2010-03-09
HISTORICAL
J1127_201003
This standard covers low voltage battery cable intended for use at a nominal system voltage of 60 V DC (25 V AC) or less in surface vehicle electrical systems. The tests are intended to qualify cables for normal applications with limited exposure to fluids and physical abuse.
Standard

Low Voltage Battery Cable

2012-10-18
HISTORICAL
J1127_201210
This standard covers low voltage battery cable intended for use at a nominal system voltage of 60 V DC (25 V AC) or less in surface vehicle electrical systems. The tests are intended to qualify cables for normal applications with limited exposure to fluids and physical abuse.
Standard

Low Tension Primary Cable

2000-05-17
HISTORICAL
J1128_200005
This SAE Standard covers low tension primary cable intended for use at a nominal system voltage of 60 V DC (25 V AC) or less in surface vehicle electrical systems. The tests are intended to qualify cables for normal applications with limited exposure to fluids and physical abuse.
Standard

LOW TENSION PRIMARY CABLE

1975-11-01
HISTORICAL
J1128_197511
This standard covers low tension primary cable intended for use at 50 V or less in surface vehicle wiring. Requirements for cable sizes 20 through 4 previously contained in SAE Standard, Low Tension Cable—SAE J558 and SAE Recommended Practice, Low Tension Cable Thermosetting Insulation—SAE J878, are included. Cable sizes 6 through 4/0 previously specified in SAE J558 are now included in SAE J1127.
Standard

LOW TENSION PRIMARY CABLE

1988-06-01
HISTORICAL
J1128_198806
This standard covers low tension primary cable intended for use at 50V or less in surface vehicle electrical systems.
Standard

LOW TENSION PRIMARY CABLE

1987-11-01
HISTORICAL
J1128_198711
This standard covers low tension primary cable intended for use at 50V or less in surface vehicle electrical systems.
Standard

High Voltage Shielded and Jacketed Cable

2021-10-12
CURRENT
J2840_202110
This document covers cable, shielded and jacketed, intended for use at a nominal system voltage up to 1000 V (AC rms or DC). It is intended for use in surface vehicle electrical systems.
Standard

FUSIBLE LINKS

1970-02-01
HISTORICAL
J156_197002
This SAE Recommended Practice covers the details, use, arid design evaluation testing of fusible links for highway vehicle electrical wiring protection. The specifications as listed are known good practice and are not intended to restrict new materials or construction.
Standard

FUSIBLE LINKS

1994-06-01
HISTORICAL
J156_199406
This SAE Standard covers the design and evaluation of fusible links for use at a nominal system voltage of 50 V or less in surface vehicle electrical systems.
Standard

FUSIBLE LINKS

1977-04-01
HISTORICAL
J156A_197704
This SAE Recommended Practice covers the details, use, and design evaluation testing of fusible links for motor vehicle electrical wiring protection. The specifications as listed are known good practice and are not intended to restrict new materials or construction.
Standard

FUSIBLE LINKS

1986-04-01
HISTORICAL
J156_198604
This SAE Recommended Practice covers the details, use, and design evaluation testing of fusible links for motor vehicle electrical wiring protection. The specifications as listed are known good practice and are not intended to restrict new materials or construction.
Standard

Battery Cable

2000-05-17
HISTORICAL
J1127_200005
This SAE Standard covers low tension battery cable intended for use at a nominal system voltage of 60 V DC (25 V AC) or less in surface vehicle electrical systems. The tests are intended to qualify cables for normal applications with limited exposure to fluids and physical abuse.