Refine Your Search

Search Results

Viewing 1 to 6 of 6
Technical Paper

Utilization of Single Cantilever Beam Test for Characterization of Ice Adhesion

2019-06-10
2019-01-1949
Many engineering systems operating in a cold environment are challenged by ice accretion, which unfavorably affects their aerodynamics and degrades both their performance and safety. Precise characterization of ice adhesion is crucial for an effective design of ice protection system. In this paper, a fracture mechanics-based approach incorporating single cantilever beam test is used to characterize the near mode-I interfacial adhesion of a typical ice/aluminum interface with different surface roughness. In this asymmetric beam test, a thin layer of ice is formed between a fixed and elastically deformable beam subjected to the applied loading. The measurements showed a range of the interfacial adhesion energy (GIC) between 0.11 and 1.34 J/m 2, depending on the substrate surface roughness. The detailed inspection of the interfacial ice fracture surface, using fracture surface replication technique, revealed a fracture mode transition with the measured macroscopic fracture toughness.
Journal Article

Numerical and Experimental Investigation of Ice Adhesion Using the Blister Test

2019-06-10
2019-01-1948
Structures in cold weather environments are susceptible to atmospheric ice formation. A fracture mechanics based approach is proposed for in situ characterization of the interfacial fracture energy of ice on different substrates. This paper summarizes the development of the experimental and analytical framework to measure the ice adhesion energy, calibrated on static ice. The testing configuration utilizes a shaft-loaded blister test to produce stable crack propagation, from a well-defined pre-crack at the interface of the ice layer and the substrate. Measurements of the fracture energy are taken over a range of ice thicknesses and surface roughnesses. The developed analytical framework to estimate adhesion energy are verified and calibrated via finite element numerical simulation of the proposed geometric configuration and employing cohesive surfaces along the interface to simulate the crack nucleation and propagation process.
Technical Paper

Characterization of Mode-II Interfacial Fracture Toughness of Ice/Metal Interfaces

2019-06-10
2019-01-1947
Airborne, marine and ground structures are vulnerable to atmospheric icing in cold weather operation conditions. Most of the ice adhesion-related work have focused on the mechanical ice removal strategies because of practical considerations, while limited literature is available for fundamental understanding of the ice adhesion process. Here, we present a fracture mechanics-based approach to characterize interfacial fracture parameters for the shear behavior of a typical ice/aluminum interface. An experimental framework employing two complementary tests (1) lap shear and (2) shear push-out tests was introduced to assess the mode-II fracture parameters for the selected aluminum/ice interface. Both analytical (shear-lag analysis) and numerical (finite element analysis incorporating cohesive zone method) models were used to evaluate shear fracture parameters.
Technical Paper

An Experimental Study on the Effects of the Layout of DBD Plasma Actuators on Its Anti-/De-Icing Performance for Aircraft Icing Mitigation

2019-06-10
2019-01-2033
Recently developed dielectric barrier discharge (DBD) plasma-based anti-icing systems have shown great potential for aircraft icing mitigation. In the present study, the ice accretion experiments were performed on to evaluate the effects of different layouts of DBD plasma actuators on their anti-/de-icing performances for aircraft icing mitigations. An array of DBD plasma actuators were designed and embedded on the surface of a NACA0012 airfoil/wing model in different layout configurations (i.e., different alignment directions of the plasm actuators (e.g., spanwise vs. streamwise), width of the exposed electrodes and the gap between the electrodes) for the experimental study. The experimental study was carried out in the Icing Research Tunnel available at Iowa State University (i.e., ISUIRT).
Technical Paper

An Experimental Study on a Hot-Air-Based Anti-/De-Icing System for the Icing Protection of Aero-Engine Inlet Guide Vanes

2019-06-10
2019-01-2039
In the present study, an experimental investigation was conducted to characterize a hot-air-based anti-/de-icing system for the icing protection of aero-engine inlet guide vanes(IGVs). The experimental study was conducted in a unique icing research tunnel available at Iowa State University (i.e., ISU-IRT). A hollowed IGV model embedded with U-shaped hot-air flowing conduit was designed and manufactured for the experimental investigations. During the experiments, while a high-speed imaging system was used to record the dynamic ice accretion or anti-/de-icing process over the surface of the IGV model for the test cases without and with the hot-air supply system being turned on, the corresponding surface temperature distributions on the IGV model were measured quantitatively by using a row of embedded thermocouples.
Technical Paper

An Experimental Investigation of a Wind-Driven Water Droplet over the Slippery Liquid Infused Porous Surface

2019-06-10
2019-01-1951
The promising anti-icing performance of the slippery liquid infused porous surface (SLIPS) has been recently demonstrated for various engineering applications. The runback icing for aircraft and wind turbines could be effectively mitigated considering the timely removal of water droplet by the wind shearing force due to the low adhesion on the SLIPS. In this study, the flow field both inside and around the wind-driven droplet over the SLIPS was experimentally investigated by using Particle Image Velocimetry (PIV) technique. Previous studies majorly focus on the internal flow pattern before the droplet incipient motion. In this study, the flow field inside a moving droplet was firstly investigated. As a result of the low surface adhesion of the SLIPS, droplet oscillations were eliminated and the droplet internal flow field could be corrected from the optical distortion.
X