Technical Paper

A New Approach to Particulate Measurement on Transient Test Cycles: Partial Flow Dilution as Alternative to CVS Full Flow Systems

2000-03-06
2000-01-1134
In a subproject of the aim to develop a worldwide certification procedure for heavy-duty on-highway engines (WHDC), the measuring technique for future low emitting engines was evaluated. One aspect is the introduction of partial flow dilution systems for the particulates measurement during transient test cycles instead of the currently required full flow dilution systems. This paper presents an investigation about the influence of sensitive sampling parameters on particulate mass and composition under steady state and transient engine operating conditions, and their effect on the correlation between partial flow and full flow dilution systems. The study has shown that the sampling parameters investigated have no or only minor influence on particulate mass and composition. Both partial flow dilution systems proved their transient capability by tracking the exhaust flow signal very well.
Technical Paper

Development of the Direct Nonmethane Hydrocarbon Measurement Technique for Vehicle Testing

2003-03-03
2003-01-0390
The Automotive Industry/Government Emissions Research CRADA (AIGER) has been working to develop a new methodology for the direct determination of nonmethane hydrocarbons (DNMHC) in vehicle testing. This new measurement technique avoids the need for subtraction of a separately determined methane value from the total hydrocarbon measurement as is presently required by the Code of Federal Regulations. This paper will cover the historical aspects of the development program, which was initiated in 1993 and concluded in 2002. A fast, gas chromatographic (GC) column technology was selected and developed for the measurement of the nonmethane hydrocarbons directly, without any interference or correction being caused by the co-presence of sample methane. This new methodology chromatographically separates the methane from the nonmethane hydrocarbons, and then measures both the methane and the backflushed, total nonmethane hydrocarbons using standard flame ionization detection (FID).
Technical Paper

Emissions Performance of GTL Diesel Fuel and Blends with Optimized Engine Calibrations

2005-05-11
2005-01-2187
The results of a comprehensive experimental investigation into the exhaust emission performance and combustion properties of neat and blended Gas-To-Liquids (GTL) diesel fuel are presented. A sulphur-free European diesel fuel was used as the reference fuel, and two blends of the GTL diesel fuel with the reference fuel, containing 20% and 50% GTL diesel fuel respectively, were investigated. The study was based on a Mercedes Benz 2.2 liter passenger car diesel engine and presents emission data for both the standard engine calibration settings, as well as settings which were optimized to match the characteristics of each fuel. Vehicle emission tests showed that the GTL diesel fuel results in reductions in HC and CO emissions of greater than 90%, while PM is reduced by 30%, and NOx remains approximately unchanged. Engine bench dynamometer tests showed reductions in soot of between 30% and 60%, and NOx reductions of up to 10% with the GTL diesel fuel, depending on the operating point.
Technical Paper

New Methods for Emission Analyzer Calibrations

1999-03-01
1999-01-0153
Traditionally, vehicle emission testing has used non-intelligent analyzers to meet government-regulated standards. Typically, these instruments would provide a 0 to 5-volt signal to a central test cell computer which would then handle all calibrations including analyzer linearization, zero and span corrections, stability checks, time delays, and sample readings. Modern gas analyzers now contain intelligence within each individual analyzer; this has caused the calibration methods to change dramatically. New methods were developed in the bench control system to take advantage of the intelligence of the analyzers by creating a distributed control architecture. The zeroing, spanning, and linearization methods are quite different from the previous protocols. The results, however, will provide more accurate reading to be used in calculating vehicle emissions.
Technical Paper

On Road Testing of Advanced Common Rail Diesel Vehicles with Biodiesel from the Jatropha Curcas plant

2005-10-23
2005-26-356
This paper addresses the use of neat, indigenous biodiesel in advanced Mercedes-Benz passenger cars. Modern, unmodified EU3 Common-Rail diesel engines with second generation common rail technology were used to determine the effects of neat biodiesel on performance and emission characteristics. The biodiesel was made from the seeds of the Jatropha Curcas plant and sourced from the Central Salt and Marine Chemicals Research Institute in Bhavnagar, India. The production of biodiesel and the vehicle tests are part of a PPP project, funded jointly by the DaimlerChrysler AG and the German DEG. The project aims at providing additional jobs and income in rural Indian areas along with reclaiming unused wasteland. The test vehicles were operated for a cumulative 8000 kilometers with an intention to expose the vehicle and fuel to diverse climatic conditions.
Technical Paper

Parameters Affecting Direct Vehicle Exhaust Flow Measurement

2003-03-03
2003-01-0781
As SULEV emission regulations approach, the bag mini-diluter (BMD) technology is gaining acceptance as a replacement for the existing constant volume sampler (CVS) for SULEV exhaust emission measurement and certification. The heart of the BMD system is the direct vehicle exhaust (DVE) flow measurement system. Due to the transient nature of vehicle exhaust during a standard FTP emission test cycle, the DVE must be capable of rapid and accurate response in order to track these varying exhaust flow rates. The DVE must also be robust enough to accurately measure flow rate despite variations in exhaust gas composition, pulsation effects, and rapid changes in both exhaust temperature and pressure. One of the primary DVE systems used on BMDs is the E-Flow, an ultrasonic flow meter manufactured by Flow Technologies, Inc.
Technical Paper

Strategies to Reduce HC-Emissions During the Cold Starting of a Port Fuel Injected Gasoline Engine

2003-03-03
2003-01-0627
In view of tight emission standards, injection strategies to reduce raw HC-emissions during the cold starting of port fuel injected engines are evaluated in this study. The relevance of spray targeting and atomization is outlined in the first part of this paper. The foundation and performance of different injector concepts with respect to spray characteristics are discussed. Laboratory experiments demonstrate that concepts relying on auxiliary energy, such as air-assistance, fuel heating and injection at elevated system pressures, are capable of producing spray droplet sizes in the SMD-range of 25μm. For future injection strategies aimed at the compliance of SULEV emission levels, this target value is considered to be essential. In the second part of this paper, emission tests of selected injector concepts are carried out using a V6-3.2I ULEV engine operated both in a vehicle and on a test bench.
Technical Paper

Studies on Enhanced CVS Technology to Achieve SULEV Certification

2002-03-04
2002-01-0048
For the measurement of exhaust emissions, Constant Volume Sampling (CVS) technology is recommended by legislation and has proven its practical capability in the past. However, the introduction of new low emission standards has raised questions regarding the accuracy and variability of the CVS system when measuring very low emission levels. This paper will show that CVS has the potential to achieve sufficient precision for certification of SULEV concepts. Thus, there is no need for the introduction of new test methods involving high cost. An analysis of the CVS basic equations indicates the importance of the Dilution Factor (DF) for calculating true mass emissions. A test series will demonstrate that, by adjusting the dilution and using state of the art analyzers, the consistency of exhaust results is comparable with those of LEV concepts, measured with conventional CVS systems and former standard analyzers.