Refine Your Search

Search Results

Viewing 1 to 11 of 11
Journal Article

Analysis of Diesel Spray Momentum Flux Spatial Distribution

2011-04-12
2011-01-0682
In the present paper the results of an experimental and numerical analysis of a common-rail, high pressure Diesel spray evolving in high counter pressure conditions is reported. The experimental study was carried out mainly in terms of spray momentum flux indirect measurement by the spray impact method; the measurement of the impact force time-histories, along with the CFD analysis of the same phenomenon, gave interesting insight in the internal spray structure. As well known, the overall spray structure momentum flux along with the injection rate measurements can be used to derive significant details about the in-nozzle flow and cavitation phenomena intensity. The same global spray momentum and momentum flux measurement can be useful in determining the jet-to-jet un-uniformities also in transient, engine-typical injection conditions which can assist in the matching process between the injection system and the combustion chamber design.
Technical Paper

Evaluation of Diesel Spray Momentum Flux in Transient Flow Conditions

2010-10-25
2010-01-2244
In the present paper, a detailed numerical and experimental analysis of a spray momentum flux measurement device capability is presented. Particular attention is devoted to transient, engine-like injection events in terms of spray momentum flux measurement. The measurement of spray momentum flux in steady flow conditions, coupled with knowledge of the injection rate, is steadily used to estimate the flow mean velocity at the nozzle exit and the extent of flow cavitation inside the nozzle in terms of a velocity reduction coefficient and a flow section reduction coefficient. In the present study, the problem of analyzing spray evolution in short injection events by means of jet momentum flux measurement was approached. The present research was based on CFD-3D analysis of the spray-target interaction in a momentum measurement device.
Technical Paper

Experimental Analysis of Fuel and Injector Body Temperature Effect on the Hydraulic Behavior of Latest Generation Common Rail Injection Systems

2018-04-03
2018-01-0282
The present paper describes the effect of thermal conditions on the hydraulic behavior of Diesel common rail injectors, with a particular focus on low temperatures for fuel and injector body. The actual injection system thermal state can significantly influence both the injected quantity and the injection shape, requiring proper amendments to the base engine calibration in order to preserve the combustion efficiency and pollutant emissions levels. In particular, the introduction of the RDE (Real Driving Emission) test cycle widens the effective ambient temperature range for the homologation cycle, this way stressing the importance of the thermal effects analysis. An experimental test bench was developed in order to characterize the injector in an engine-like configuration, i.e. fuel pump, piping, common rail, pressure control system and injectors.
Technical Paper

Experimental High Temperature Analysis of a Low-Pressure Diesel Spray for DPF Regeneration

2019-09-09
2019-24-0035
In the current automotive scenario, particulate filter technology is mandatory in order to attain emission limits in terms of particulate matter for diesel engines. Despite the fact that the Diesel Particulate Filter (DPF) is often considered a mature technology, significant issues can result from the use of the engine fuel injectors to introduce into the exhaust pipe the fuel needed to ignite the particulate matter accumulated in the filter during its regeneration. The most important issue is lubricant oil dilution with fuel as a consequence of significant spray impact on the cylinder liner. As an alternative, the fuel required to start DPF regeneration can be introduced in the exhaust pipe by an auxiliary low-pressure injector spraying in the hot exhaust gas stream.
Technical Paper

Experimental and Numerical Analysis of Spray Evolution, Hydraulics and Atomization for a 60 MPa Injection Pressure GDI System

2018-04-03
2018-01-0271
In recent years, the GDI (Gasoline Direct Injection) technology has significantly spread over the automotive market under the continuous push toward the adoption of combustion systems featuring high thermodynamic conversion efficiency and moderate pollutant emissions. Following this path, the injection pressure level has been progressively increased from the initial 5-15 MPa level nowadays approaching 35 MPa. The main reason behind the progressive injection pressure increase in GDI engines is the improved spray atomization, ensuring a better combustion process control and lower soot emissions. On the other hand, increasing injection pressure implies more power absorbed by the pumping system and hence a penalty in terms of overall efficiency. Therefore, the right trade-off has to be found between soot formation tendency reduction thanks to improved atomization and the energetic cost of a high pressure fuel injection system.
Technical Paper

Experimental and Numerical Analysis of a Swirled Fuel Atomizer for an Aftertreatment Diesel Burner

2023-08-28
2023-24-0106
Emission legislation for light and heavy duty vehicles is requiring a drastic reduction of exhaust pollutants from internal combustion engines (ICE). Achieving a quick heating-up of the catalyst is of paramount importance to cut down cold start emissions and meet current and new regulation requirements. This paper describes the development and the basic characteristics of a novel burner for diesel engines exhaust systems designed for being activated immediately at engine cold start or during vehicle cruise. The burner is comprised of a swirled fuel dosing system, an air system, and an ignition device. The main design characteristics are presented, with a detailed description of the atomization, air-fuel interaction and mixture formation processes. An atomizer prototype has been extensively analyzed and tested in various conditions, to characterize the resulting fuel spray under cold-start and ambient operating conditions.
Technical Paper

Experimental and Numerical Momentum Flux Analysis of Jets from a Hydrogen Injector

2024-04-09
2024-01-2616
The use of hydrogen in internal combustion engines is an effective approach to significantly support the reduction of CO2 emissions from the transportation sector using technically affordable solutions. The use of direct injection is the most promising approach to fully exploit hydrogen potential as a clean fuel, while preserving targets in terms of power density and emissions. In this frame, the development of an effective combustion system largely relies on the hydrogen-air mixture formation process, so to adequately control the charge stratification to mitigate pre-ignitions and knock and to minimize NOx formation. Hence, improving capabilities of designing a correct gas jet-air interaction is of paramount importance. In this paper the analysis of the evolution of a high-pressure gas jet produced by a single-hole prototype injector operated with different pressure ratios is presented.
Technical Paper

Injection Rate Measurement of GDI Systems Operating against Sub-Atmospheric and Pressurized Downstream Conditions

2017-09-04
2017-24-0110
In order to optimize gasoline direct injection combustion systems, a very accurate control of the fuel flow rate from the injector must be attained, along with appropriate spray characteristics in terms of drop sizing and jets global penetration/diffusion in the combustion chamber. Injection rate measurement is therefore one of the crucial tasks to be accomplished in order both to develop direct injection systems and to properly match them with a given combustion system. Noticeably, the hydraulic characteristics of GDI injectors should be determined according to a non-intrusive measuring approach. Unfortunately, the operation of all conventional injection analyzers requires the injection in a volume filled with liquid and the application of a significant counter-pressure downstream of the injector. This feature prevents any operation with low pressure injection systems such as PFIs.
Technical Paper

Momentum Flux Spatial Distribution and PDA Analysis of a GDI Spray

2012-04-16
2012-01-0459
In the present paper, the results of a detailed experimental analysis of a GDI spray based on Imaging, Phase Doppler Anemometry data and Momentum Flux distribution measurement are presented and discussed. The GDI system used is a three-hole research injector, operated in an injection pressure range of 50 bar to 150 bar. Spray Imaging is performed according to an ensemble average approach, acquiring images at different timings during the injection process; the resulting penetration and cone angle time-histories allow a quantitative description of the spray structure shape. Momentum flux distribution data are obtained by means of a dedicated test bench which detects the impact force of small spray portions. The sensing device is moved in different positions inside the spray structure, with the acquired force transients averaged on several injection events.
Technical Paper

Numerical Simulation of Non-reacting Ducted Fuel Injection by Means of the Diffuse-Interface Σ-Y Atomization Model

2022-03-29
2022-01-0491
Ducted Fuel Injection (DFI) is a new technology recently developed with the aim of reducing soot emission formation in diesel compression ignition engines. DFI concept consists of the injection of fuel spray through a small duct located downstream of the injector nozzle leaving a certain gap, the so-called Stand-off distance. Currently, CFD modelers have investigated its performance using classical spray modeling techniques such as the Discrete Drops Method (DDM). However, as discussed in the literature, this type of technique is inappropriate when applied to dense jets as those occurring in diesel sprays, especially in the near-nozzle region (where the duct is placed). Therefore, considering a more appropriate modeling technique for such a problem is mandatory. In this research work, an Eulerian single-fluid diffuse-interface model called Σ-Y and implemented in the OpenFOAM framework is utilized for the simulation of non-reacting conditions.
Technical Paper

Numerical Simulations and Experimental Validation of an SCR System for Ultra Low NOx Applications

2021-09-21
2021-01-1222
Close-coupled aftertreatment systems (ATS) for automotive Diesel engines composed of DOC and SCR offer a significant potential in terms of pollutant emission control capability even with the introduction of more aggressive driving cycles and rigorous limits for type-approval tests. This is particularly important for incoming certification standards where the forecast is showing a trade-off towards ultra-low NOx emissions values. As the SCR system NOx conversion capability largely relies on both the UWS mixing device and on NOx sensors used to detect the actual NH3 slip and residual NOx concentration, developing numerical simulation tools for the analysis of the actual flow pattern and species concentration over peculiar sections of the exhaust system is crucial to support the ATS development process.
X