Refine Your Search

Search Results

Viewing 1 to 9 of 9
Technical Paper

Analysis of the Physical Characteristics of Diesel Particulate Matter Using Transmission Electron Microscope Techniques

1979-02-01
790815
An Andersen Impactor was used to collect particulate samples in both the undiluted and diluted exhaust from a Caterpillar 3150 diesel engine operated on the EPA 13-mode cycle. A total of 24 samples were examined using the transmission electron microscope and approximately 300 photomicrographs were taken. The microscope analysis and photomicrographs revealed details concerning the physical characteristics of the particulate and permitted a direct visual comparison of the samples collected. The photomicrographs were used to obtain diameter measurements of the basic individual spherical particles that comprise the much larger aggregates/agglomerates. Nearly 11,000 basic particles were measured and the observed range of diameters was 70-1200 Å. The mean particle diameters in the undiluted and diluted exhaust samples were 479 Å and 436 Å respectively. respectively. A respectively. 436 A respectively.
Technical Paper

Design and Computer Simulation of Microprocessor Controlled Lubricating Oil Cooling System for Truck Diesel Engine

1988-02-01
880488
A microprocessor controlled lubricating oil cooling system of truck diesel engine was designed to minimize the sump oil temperature fluctuation during start-up and nonsteady engine operations. Model reference adaptive control method is utilized in the control system design. The analysis involved in the design of the microprocessor controlled oil cooling system, and the applications of a special vehicle-engine-cooling system (VEC) computer simulation code in the implementation and testing of the model reference adaptive control strategy are described. Using the VEC simulation code, the performance of the microprocessor controlled oil cooling system and the conventionally controlled oil cooling systems were compared for the ATB, temperature disturbances, and cold weather transient tests. An explanation of each test, as well as a review of the results of comparison tests are presented.
Journal Article

Penetration Calibration and Verification for the Solid Particle Counting System with Polydisperse and Monodisperse Particles

2008-04-14
2008-01-1178
Monodisperse and polydisperse Sodium Chloride (NaCl) particles were used to calibrate the solid particle penetration for the Volatile Particle Remover (VPR) in a Horiba prototype Solid Particle Counting System (SPCS). Prior to the calibration, dilution ratios on the SPCS are verified carefully with a flame ionization analyzer (FIA). Size distributions for polydisperse aerosols upstream and downstream of the Volatile Particle Remover (VPR) were measured with a Scanning Mobility Particle Sizer (SMPS). It is found that overall penetrations for polydisperse aerosols are larger than 95%. Geometric standard deviations from the raw and the diluted by the VPR are within ±1.5% difference. Thus, shapes of size distributions aren't changed after dilution. Geometric mean diameters shift a little, on average ±5% after dilution. Therefore, the VPR doesn't change the aerosol characteristics after the aerosol is diluted and heated up to 320 °C.
Technical Paper

Physical Size Distribution Characterization of Diesel Particulate Matter and the Study of the Coagulation Process

1978-02-01
780788
Diesel particulate matter in both the diluted and undiluted state is subject to the processes of coagulation, condensation or evaporation, and nucleation which causes continuous changes in its physical characteristics. The Electrical Aerosol Analyzer (EAA) is used to measure the diesel particle size distribution in the MTU dilution tunnel for a naturally aspirated direct-injection diesel engine operated on the EPA 13 mode cycle. The design and development of accurate and repeatable sampling methods using the EAA are presented. These methods involve both steady-state tunnel and bag measurements. The data indicate a bimodal nature within the 0.001 to 1 μm range. The first mode termed the “embroynic mode” has a saddle point between 0.005 to 0.015 μm and the second mode termed the “aggregation mode” lies between .08 to .15 μm for the number distribution.
Technical Paper

Single-Stage Dilution Tunnel Design

2001-03-05
2001-01-0207
A single-stage dilution system has been designed to simulate the process of engine exhaust dilution in the atmosphere. An exhaust sample stream is introduced into a partial flow tunnel where it is diluted at a controlled rate. Temperature, relative humidity, dilution ratio and rate, and residence time are all adjustable. The system includes a turbulence generator to adjust the intensity of turbulence in the tunnel and a wake disk to control the initial mixing rate. Numerical methods were used to simulate flow fields, velocity fields, and mixing profiles for gases and particles. Mixing profiles for a gaseous tracer and particles of different sizes were also determined experimentally and compared with the model predictions. Critical parameters that influence mixing profiles and dilution rates predicted by modeling were demonstrated experimentally. Predicted and measured normalized mixing profiles were found to be in good agreement.
Technical Paper

Single-Stage Dilution Tunnel Performance

2001-03-05
2001-01-0201
A one-stage dilution tunnel has been developed to sample and dilute diesel exhaust. The tunnel has the capability of simulating many aspects of the atmospheric dilution process. The dilution rate and overall dilution ratio, temperature, relative humidity, and residence time in the tunnel, as well as residence time and temperature in the transfer line between the tunnel and exhaust sampling point may be varied. In this work we studied the influence of the exhaust transfer line, tunnel residence time, and dilution air temperature on the exhaust particle size distribution. The influences of fuel sulfur content on the size distribution and on the sensitivity of the size distribution to dilution and sampling conditions were also examined. We do not suggest an optimum dilution scheme, but do identify critical variables.
Technical Paper

The Characterization of the Hydrocarbon and Sulfate Fractions of Diesel Particulate Matter

1978-02-01
780111
One of the more objectionable aspects of the use of diesel engines has been the emission of particulate matter. A literature review of combustion flames, theoretical calculations and dilution tunnel experiments have been performed to elucidate the chemical and physical processes involved in the formation of diesel particulate matter. A comparative dilution tunnel study of diluted and undiluted total particulate data provided evidence supporting calculations that indicate hydro-carbon condensation should occur in the tunnel at low exhaust temperatures. The sample collection system for the measurement of total particulate matter and soluble sulfate in particulate matter on the EPA 13 mode cycle is presented. A method to correct for hydrocarbon interferences in the EPA barium chloranilate method for the determination of sulfate in particulate matter is discussed.
Technical Paper

The Vehicle Engine Cooling System Simulation Part 1 - Model Development

1999-03-01
1999-01-0240
The Vehicle Engine Cooling System Simulation (VECSS) computer code has been developed at the Michigan Technological University to simulate the thermal response of the cooling system of an on-highway heavy duty diesel powered truck under steady and transient operation. This code includes an engine cycle analysis program along with various components for the four main fluid circuits for cooling air, cooling water, cooling oil, and intake air, all evaluated simultaneously. The code predicts the operation of the response of the cooling circuit, oil circuit, and the engine compartment air flow when the VECSS is operated using driving cycle data of vehicle speed, engine speed, and fuel flow rate for a given ambient temperature, pressure and relative humidity.
Technical Paper

The Vehicle Engine Cooling System Simulation Part 2 – Model Validation Using Transient Data

1999-03-01
1999-01-0241
The Vehicle Engine Cooling System Simulation (VECSS) computer code has been developed at the Michigan Technological University to simulate the thermal response of a cooling system for an on-highway heavy duty diesel powered truck under steady and transient operation. In Part 1 of this research, the code development and verification has been presented. The revised and enhanced VECSS (version 8.1) software is capable of simulating in real-time a Freightliner FLD 120 truck with a Detroit Diesel Series 60 engine, Behr McCord radiator, Allied signal / Garrett Automotive charge air cooler and turbocharger, Kysor DST variable speed fan clutch, DDC oil and coolant thermostat. Other cooling system components were run and compared with experimental data provided by Kysor Cooling Systems. The experimental data were collected using the Detroit Diesel Electronic Control's (DDEC) Electronic Control Module (ECM) and the Hewlett Packard (HP) data acquisition system.
X