Refine Your Search

Topic

Search Results

Standard

Dispenser Nozzle Spouts for Liquid Fuels Intended for Use with Spark Ignition and Compression Ignition Engines

2012-05-31
HISTORICAL
J285_201205
This SAE recommended practice provides standard dimensions for liquid fuel dispenser nozzle spouts and a system for differentiating between nozzles that dispense liquid fuel into vehicles with Spark Ignition (SI) Engines and Compression Ignition (CI) Engines for land vehicles. Current legal definitions only distinguish between “UNLEADED Fuel” and “All Other Types of Fuel.” These definitions are no longer valid. This document establishes a new set of definitions that have practical application to current automobile liquid fuel inlets and liquid fuel dispenser nozzle spouts.
Standard

Dispenser Nozzle Spouts for Liquid Fuels Intended for Use with Spark Ignition and Compression Ignition Engines

2007-04-23
HISTORICAL
J285_200704
This SAE recommended practice provides standard dimensions for liquid fuel dispenser nozzle spouts and a system for differentiating between nozzles that dispense liquid fuel into vehicles with Spark Ignition (SI) Engines and Compression Ignition (CI) Engines for land vehicles. Current legal definitions only distinguish between “UNLEADED Fuel” and “All Other Types of Fuel.” These definitions are no longer valid. This document establishes a new set of definitions that have practical application to current automobile liquid fuel inlets and liquid fuel dispenser nozzle spouts.
Standard

Dispenser Nozzle Spouts for Liquid Fuels Intended for Use with Spark Ignition and Compression Ignition Engines

2019-04-29
CURRENT
J285_201904
This SAE Recommended Practice provides standard dimensions for liquid fuel dispenser nozzle spouts and a system for differentiating between nozzles that dispense liquid fuel into vehicles with spark ignition (SI) engines and compression ignition (CI) engines for land vehicles. Current legal definitions only distinguish between “Unleaded Fuel” and “All Other Types of Fuel.” These definitions are no longer valid. This document establishes a new set of definitions that have practical application to current automobile liquid fuel inlets and liquid fuel dispenser nozzle spouts.
Standard

Fuel Filler Pipe Assembly Design Practice to Meet Low Evaporative Emission Requirements

2002-11-07
HISTORICAL
J2599_200211
This SAE Recommended Practice covers design and evaluation of the entire gasoline filler pipe assembly used on cars and light trucks with respect to compliance with CARB (California Air Resources Board) LEV II (meeting or exceeding EPA Tier 2 and EU Stage-5 evaporative emissions requirements). It is limited to an assembly which is joined to the fuel tank using either a hose, Quick Connect Coupling, or a grommet type sealing device. The Design Practice covers the filler cap, filler pipe, filler pipe assembly to tank hose, and filler pipe assembly to tank grommet or spud. It includes recommendations for design of components and assemblies intended to perform successfully in evaporative emission SHED (Sealed Housing for Evaporative Determination) tests, based on best practices known at the time of release.
Standard

Fuel Filler Pipe Assembly Design Practice to Meet Low Evaporative Emission Requirements

2003-04-25
HISTORICAL
J2599_200304
This SAE Recommended Practice covers design and evaluation of the entire gasoline filler pipe assembly used on cars and light trucks with respect to compliance with CARB (California Air Resources Board) LEV II (meeting or exceeding EPA Tier 2 and EU Stage-5 evaporative emissions requirements). It is limited to an assembly which is joined to the fuel tank using either a hose, Quick Connect Coupling, or a grommet type sealing device. The Design Practice covers the filler cap, filler pipe, filler pipe assembly to tank hose, and filler pipe assembly to tank grommet or spud. It includes recommendations for design of components and assemblies intended to perform successfully in evaporative emission SHED (Sealed Housing for Evaporative Determination) tests, based on best practices known at the time of release.
Standard

Fuel System—Electrostatic Charge

1999-01-01
HISTORICAL
J1645_199901
The purpose of this SAE Recommended Practice is to provide an explanation of electrostatic charge phenomena as they relate to automotive fuel systems and how those phenomena should be handled if they develop. This document is limited to the group of components that are known as the fuel system and only those that handle liquid fuel in one of two situations: operation of the fuel delivery system and refueling of the vehicle. This is a collection of ideas and generalities that are summarized from literature and presentations, inferred from some laboratory experimentation and summarized from experiences within the automotive industry as interpreted by the Electrostatics Subcommittee of the SAE Fuel Lines and Fittings Standards Committee. Some of the discussions are simplified. If users of this document need some further technical information, experts should be consulted or the references cited here should be examined directly.
Standard

Gasoline, Alcohol, and Diesel Fuel Surrogates for Materials Testing

2000-01-10
HISTORICAL
J1681_200001
This SAE Recommended Practice presents recommendations for test fluids that can be used to simulate real world fuels. The use of standardized test fluids is required in order to limit the variability found in commercial fuels and fluids. Commercial fuels can vary substantially between manufacturers, batches, seasons, and geographic location. Further, standardized test fluids are universally available and will promote consistent test results for materials testing. Therefore, this document a Explains commercial automotive fuel components b Defines standardized components of materials test fluids c Defines a nomenclature for test fluids d Describes preparations for test fluids and e Recommends fluids for testing fuel system materials The test fluid compositions specified in Section 7 of this document are recommended solely for evaluating materials.
Standard

NONMETALLIC FUEL SYSTEM TUBING

1994-05-01
HISTORICAL
J2043_199405
This SAE Standard covers the minimum requirements for nonmetallic tubing as manufactured for use in gasoline or diesel fuel systems. It is not intended to cover tubing for any portion of the system which operates below -40 °C, above 115 °C, or above a maximum working gage pressure of 690 kPa.
Standard

Optimized Fuel Tank Sender Closure

2019-03-08
CURRENT
J2587_201903
This practice describes recommended performance requirements of fuel tank closures used in conjunction with fuel level senders and fuel delivery systems. It provides guidelines that assure interchangeability and compatibility between fuel tanks and fuel pump/sender closure systems without specifying a specific closure system design. These systems may be used in rigid fuel tank systems made of plastic or metal. Complete details of specific designs shall be established by mutual agreement between customer and supplier. The dimensions and performance requirements are selected to optimize a The closure system, durability and reliability with respect to — Vehicle SHED measurements — Fuel system / crash integrity — LEV – II useful life b Assembly and service ease and reliability c Packaging of fuel tanks and their sending units d Interchangeability of sender closures between various fuel tank designs
Standard

Optimized Fuel Tank Sender Closure

2005-10-25
HISTORICAL
J2587_200510
This practice describes recommended performance requirements of fuel tank closures used in conjunction with fuel level senders and fuel delivery systems. It provides guidelines that assure interchangeability and compatibility between fuel tanks and fuel pump/sender closure systems without specifying a specific closure system design. These systems may be used in rigid fuel tank systems made of plastic or metal. Complete details of specific designs shall be established by mutual agreement between customer and supplier. The dimensions and performance requirements are selected to optimize a The closure system, durability and reliability with respect to — Vehicle SHED measurements — Fuel system / crash integrity — LEV – II useful life b Assembly and service ease and reliability c Packaging of fuel tanks and their sending units d Interchangeability of sender closures between various fuel tank designs
Standard

PRELIMINARY STANDARD FOR PROTECTIVE COVERS FOR GASOLINE FUEL LINE TUBING

1994-06-01
HISTORICAL
J2027_199406
This SAE Standard covers the performance requirements for protective covers for gasoline fuel tubing. The ultimate performance of the protective cover can be highly dependant on the interaction of the fuel line tubing and protective cover. Therefore, it is recommended that specific tubing and cover combinations be tested as an assembly to qualify to this document.
Standard

Performance Requirements for Fuel System Tubing Assemblies

2017-12-01
WIP
J2045
This SAE Standard encompasses the recommended minimum requirements for non-metallic tubing and/or combinations of metallic tubing to non-metallic tubing assemblies manufactured as liquid- and/or vapor-carrying systems designed for use in gasoline, alcohol blends with gasoline, or diesel fuel systems. This SAE Standard is intended to cover tubing assemblies for any portion of a fuel system which operates above –40 °C (–40 °F) and below 115 °C (239 °F), and up to a maximum working gage pressure of 690 kPa (100 psig). The peak intermittent temperature is 115 °C (239 °F). For long-term continuous usage, the temperature shall not exceed 90 °C (194 °F). It should be noted that temperature extremes can affect assemblies in various manners and every effort must be made to determine the operating temperature to which a specific fuel line assembly will be exposed, and design accordingly.
Standard

Performance Requirements for Fuel System Tubing Assemblies

2012-11-01
CURRENT
J2045_201211
This SAE Standard encompasses the recommended minimum requirements for non-metallic tubing and/or combinations of metallic tubing to non-metallic tubing assemblies manufactured as liquid- and/or vapor-carrying systems designed for use in gasoline, alcohol blends with gasoline, or diesel fuel systems. This SAE Standard is intended to cover tubing assemblies for any portion of a fuel system which operates above −40 °C (−40 °F) and below 115 °C (239 °F), and up to a maximum working gage pressure of 690 kPa (100 psig). The peak intermittent temperature is 115 °C (239 °F). For long-term continuous usage, the temperature shall not exceed 90 °C (194 °F). It should be noted that temperature extremes can affect assemblies in various manners and every effort must be made to determine the operating temperature to which a specific fuel line assembly will be exposed, and design accordingly.
Standard

Performance Requirements for Fuel System Tubing Assemblies

1998-02-01
HISTORICAL
J2045_199802
This SAE Standard encompasses the recommended minimum requirements for non-metallic tubing and/or combinations of metallic tubing to non-metallic tubing assemblies manufactured as a liquid- and/or vapor-carrying systems designed for use in gasoline, alcohol blends with gasoline, or diesel fuel systems. This SAE Standard is intended to cover tubing assemblies for any portion of a fuel system which operates above –40 °C (–40 °F) and below 115 °C (239 °F), and up to a maximum working gage pressure of 690 kPa (100 psi). The peak intermittent temperature is 115 °C 239 °F). For long-term continuous usage, the temperature shall not exceed 90 °C (194 °F). It should be noted that temperature extremes can affect assemblies in various manners and every effort must be made to determine the operating temperature to which a specific fuel line assembly will be exposed, and design accordingly.
Standard

QUICK CONNECTOR SPECIFICATION FOR LIQUID FUEL AND VAPOR/EMISSIONS SYSTEMS

1996-01-01
HISTORICAL
J2044_199601
This SAE Recommended Practice defines the minimum functional requirements for quick connectors used in supply, return, and vapor/emissions lines for flexible tubing systems. This document applies to automotive and light truck gasoline and diesel fuel systems with operating pressures up to 500 kPa, 5 bar, (72 psig) and operating temperatures up to 115 °C (239 °F). These tests apply to new connectors in assembly operations. Connectors must be pushed onto a mating tube end then pulled back to assure complete connection. For service operations, the mating tube should be lubricated with SAE 30 weight oil before re-connecting. Vehicle OEM fuel system specifications may impose additional requirements beyond the scope of this general SAE document. In those cases, the OEM specification takes precedence over this document.
Standard

Quick Connect Coupling Specification for Liquid Fuel and Vapor/Emissions Systems

2002-09-13
HISTORICAL
J2044_200209
This SAE Recommended Practice defines standard tube end form dimensions so as to guarantee interchangeability between all connector designs of the same size and the standard end form. This document also defines the minimum functional requirements for quick connect couplings between flexible tubing or hose and rigid tubing or tubular fittings used in supply, return, and vapor/emissions in fuel systems. This document applies to automotive and light truck applications under the following conditions: a Gasoline and diesel fuel delivery systems or their vapor venting or evaporative emission control systems. b Operating pressure up to 500 kPa, 5 bar, (72 psig). c Operating vacuum down to –50 kPa, –0.5 bar (–7.2 psi). d Operating temperatures from –40 °C (–40 °F) to 115 °C (239 °F). Quick connect couplings function by joining the connector to a mating tube end form then pulling back to assure a complete connection.
Standard

Quick Connect Coupling Specification for Liquid Fuel and Vapor/Emissions Systems

2011-01-25
WIP
J2044
This SAE Recommended Practice defines the minimum functional requirements for quick connect couplings used for supply, return, and vapor/emission fuel system connections. This document also defines standard male tube end form dimensions, so as to guarantee interchangeability between all connector designs of the same male tube end form size. This document applies to automotive and light truck applications under the following conditions: a. Gasoline and diesel fuel delivery systems or their vapor venting or evaporative emission control systems; b. Operating pressure up to 500 kPa, 5 bar, (72 psig); c. Operating vacuum down to -50 kPa, -0.5 bar (-7.2 psi); d. Operating temperatures from -40 °C (-40 °F) to 115 °C (239 °F). Quick connect couplings function by joining the connector to a mating tube end form, then pulling back to assure a complete connection. The requirements stated in this document apply to new connectors in assembly operations unless otherwise indicated.
Standard

Quick Connector Specification for Liquid Fuel and Vapor/Emissions Systems

1997-12-01
HISTORICAL
J2044_199712
This SAE Recommended Practice defines the minimum functional requirements for quick connectors used in supply, return, and vapor/emissions lines for flexible-tubing systems. This document applies to automotive and light truck gasoline and diesel fuel systems with operating pressure or vacuum up to 500 kPa, 5 bar, (72 psig) and operating temperatures up to 115 °C (239 °F). These tests apply to new connectors in assembly operations. Connectors must be pushed onto a mating tube end then pulled back to assure complete connection. For service operations, the mating tube should be lubricated with SAE 30 weight oil before re-connecting. Vehicle OEM fuel system specifications may impose additional requirements beyond the scope of this general SAE document. In those cases, the OEM specification takes precedence over this document.
Standard

SAE QUICK CONNECTOR SPECIFICATIONS FOR LIQUID FUEL SYSTEMS

1992-06-01
HISTORICAL
J2044_199206
This SAE Recommended Practice defines minimum functional requirements for quick connectors used in supply and return, liquid lines, for flexible tubing fuel systems. The document applies to automotive and light truck gasoline and diesel fuel systems, with operating pressures up to 500 kPa, 5 Bar, (72.5 psig), and the fuel lines and connectors routed such that continuous operating temperature exposure is less than 115 °C (239 °F). These tests apply to new fittings in assembly operations: for service operations, the male tube should be lubricated with engine oil before coupling. Vehicle O.E.M. fuel system specifications may impose additional requirements beyond the scope of this general SAE document. In those cases, the O.E.M. specification takes precedence over this document.
Standard

Standard for Protective Covers for Gasoline Fuel Line Tubing

1998-06-01
HISTORICAL
J2027_199806
This SAE Standard includes performance requirements for protective covers for flexible, non-metallic fuel tubing. Ultimate performance of the protective cover may be dependent on the interaction of the fuel tubing and protective cover. Therefore, it is recommended that tubing and cover combinations be tested as an assembly, where appropriate, to qualify to this document.
X