Refine Your Search

Search Results

Viewing 1 to 13 of 13
Technical Paper

Cabin Air Quality Dynamics On Board the International Space Station

2003-07-07
2003-01-2650
Spacecraft cabin air quality is influenced by a variety of factors. Beyond normal equipment offgassing and crew metabolic loads, the vehicle's operational configuration contributes significantly to overall air quality. Leaks from system equipment and payload facilities, operational status of the atmospheric scrubbing systems, and the introduction of new equipment and modules to the vehicle all influence air quality. The dynamics associated with changes in the International Space Station's (ISS ) configuration since the launch of the U.S. Segment's laboratory module, Destiny, is summarized. Key classes of trace chemical contaminants that are important to crew health and equipment performance are emphasized. The temporary effects associated with attaching each multi-purpose logistics module (MPLM) to the ISS and influence of in-flight air quality on the post-flight ground processing of the MPLM are explored.
Technical Paper

Characterizing the Influence of Temperature and Vacuum Quality on the Desorption Kinetics of Commercial Adsorbents

2008-06-29
2008-01-2096
Understanding the effects of dynamic thermal and vacuum regeneration on VOC desorption kinetics is needed for the development of regenerable trace contaminant control air revitalization systems. The effects of temperature and vacuum quality on the desorption kinetics of ethanol from Carbosieve SIII were examined using 1 hour regeneration cycles. The effect of vacuum quality on ethanol desorption was studied by exposing adsorption tubes loaded with ethanol to low pressures (1.0, 0.5, 0.3, and 0.12 atm) at various thermal regeneration temperatures (160, 100, 70, and 25 °C). At 1 atm of pressure, ethanol removal was found to increase from 2% at 25 °C, to 25% at 70 °C, to 55% at 100 °C, and to 77% at 160 °C. Decreasing the atmospheric pressure from 1 to 0.1 atm for 1 hr did not significantly enhance Carbosieve SIII regeneration at ambient temperatures (25 °C). However, heating the adsorbent at low pressures enhanced its regeneration.
Technical Paper

Design and Initial Tests of a Denitrification Composter to Stabilize Space-Mission Trash

2004-07-19
2004-01-2465
The purpose of this research is to determine the feasibility of a unique denitrifying composter to stabilize trash from space-habitation (STS, ISS, ALS) life support activities. Design criteria were derived from variables to be manipulated and those to be held constant. A pre-existing aerobic composter was used and engineering tests run to ensure that requirements were met. Key experimental variables were identified: NO3- concentration and rate of addition, O2 concentration, mixing duration and frequency, and inoculum. Independent variables were pH, temperature, moisture, C:N ratio, feed material, size reduction, feed addition rate, and mode of operation. Important performance parameters included: maximization of desired outcomes – BOD5 removal, CO2 production, waste stabilization, and denitrification – and minimization of undesired products – N2O, NH3, and volatile organic compounds.
Technical Paper

Designing a Reusable Ethylene Filter Cartridge for Plant Flight Hardware: Characterization of Thermally Desorbing Compounds

2005-07-11
2005-01-2953
The chemical specificity of several adsorbents, capable of being recycled by thermal desorption, was determined using volatile organic compounds (VOCs) found in ISS cabin air. These VOC adsorbents will be used to design a reusable filter to control ethylene in plant growth chambers and other STS/ISS biological payloads. A reusable filter to remove plant-produced ethylene from plant growth chambers could help minimize the mass and power use of plant flight hardware. Spaceflight-rated plant growth chambers employ either passive or active catalytic scrubbers for maintaining acceptable levels of VOCs. Passive systems require consumables, while active systems require power and their performance can be degraded in high humidity environments. Each adsorbent was loaded with known amounts of VOCs at a known flow rate. The filtering capacity and chemical specificity of each compound was determined from measurements pre- and post-filter VOC concentration.
Technical Paper

Development and Testing of Inocula for Biodegradation of Igepon Under Denitrifying Conditions

1999-07-12
1999-01-1949
Bioreactor technology for bioprocessing graywater solutions in microgravity is under development by NASA at Johnson Space Center and at major aerospace companies. Inoculum sources have been inconsistent. Startup and subsequent operation of ground-based bioreactors may have been adversely affected by this inconsistency and/or by inoculation procedures. The goal of the research reported in this paper is to develop an inoculum that will completely biodegrade Igepon T42 soap to carbon dioxide and water under anaerobic, denitrifying conditions and with process conditions set by bioreactor design requirements for microgravity operation. Potential inoculum sources from two habitats within the KSC-ALS breadboard project were developed for potential use. The effects of pH (7.2 vs. 9.0, buffered) on soap degradation by the two inocula was determined in a flask study. Nearly all of the soap was degraded at pH 7.2 while nearly none was degraded at pH 9.0. Both inocula behaved similarly.
Technical Paper

Effects of Relative Humidity on the Adsorption of Dichloromethane by Carbosieve SIII

2007-07-09
2007-01-3249
Carbosieve SIII was used to filter dichloromethane (DCM) from a simulated spacecraft gas stream. This adsorbent was tested as a possible commercial-off-the-shelf (COTS) filtration solution to controlling spacecraft air quality. DCM is a halocarbon commonly used in manufacturing for cleaning and degreasing and is a typical component of equipment offgassing in spacecraft. The performance of the filter was measured in dry and humid atmospheres. A known concentration of DCM was passed through the adsorbent at a known flow rate. The adsorbent removed dichloromethane until it reached the breakthrough volume. Carbosieve SIII exposed to dry atmospheric conditions adsorbed more DCM than when exposed to humid air. Carbosieve SIII is a useful thermally regenerated adsorbent for filtering DCM from spacecraft cabin air. However, in humid environments the gas passes through the filter sooner due to co-adsorption of additional water vapor from the atmosphere.
Technical Paper

Long-Term Storage of Wheat Plants for Light Microscopy

2000-07-10
2000-01-2231
The objectives of these experiments were two fold: 1) to determine if accepted tissue fixation procedures can be adapted for long-term storage on-board the International Space Station (ISS) and 2) to test whether they are suitable for KSC Fixation Tubes (KFTs). Three tissue fixation parameters were tested: time, temperature and sample size.Fixation time:samples are normally fixed from several minutes to several hours, but because of the duration of the UF-1 mission to ISS, the tissue will be in fixative for up to 3 months. Super dwarf wheat tissue samples were fixed in either FAA (a fixative normally used for storage of plant tissues) or a glutaraldehyde-based fixative and stored for 100 days.
Technical Paper

Microbial Characterization of Compacted vs. Non-Compacted Simulated Orion Crew Vehicle Food Trash Compartment Waste

2007-07-09
2007-01-3268
The effects of volume-reduction via compaction (VR-C) on microbial loads and microbially-produced noxious odors during post-treatment storage were investigated. The Crew Exploration Vehicle (CEV) / Orion simulated food trash compartment wastes (FTCW) consisted of 80% food trash with packaging and 20% wipes. Compaction was compared with a non-compacted control and will provide a baseline for comparison with other treatment technologies. The first study was a timecourse with post-treatment storage durations of 1, 2, 4, and 6 weeks. Key response variables were: O2 consumption and CO2 production from waste biodegradation and microbiological assays consisting of total counts and culturable counts of (a) aerobic and anaerobic bacteria, (b) aerobic and anaerobic spore-forming bacteria, (c) specific bacteria including Pseudomonas aeruginosa, Burkholderia cepacia, and Staphylococcus aureus counts, and (d) molds at run termination.
Technical Paper

Paecilomyces lilacinus and Fusarium verticillioides Remove t-Butanol from Contaminated Air

2006-07-17
2006-01-2150
Volatile organic compounds (VOCs) are important indoor air pollutants, particularly in spaces lacking adequate ventilation and containing off gassing materials. The problem is particularly acute in closed environments, such as spacecraft. The best solution to controlling VOC accumulation in closed environments is eliminating the offending chemicals from the spacecraft design. However, when this is not possible, removal of VOCs from spacecraft air is necessary. Two species of fungi, Paecilomyces lilacinus and Fusarium verticillioides, were tested for the ability to remove tert-butanol from air. The fungi were grown on PCA+C agar and placed into jars with high atmospheric concentrations of t-butanol. The concentration of t-butanol was monitored in the containers for one week. The t-butanol consumption rates were estimated after adjusting for leakage. Leak rates ranged from 0.0003 to 0.0027 h-1.
Technical Paper

Planning for the Rapid Aerobic Bioreactor Integration Test (RABIT) at the Kennedy Space Center's Advanced Life Support Breadboard Project

1996-07-01
961509
The National Aeronautics and Space Administration (NASA) intends to continue the human exploration of outer space. Long duration missions will require the development of reliable regenerative life support processes. The intent of this paper is to define the Kennedy Space Center Controlled Ecological Life Support System (CELSS) research plan for the development and testing of three candidate biological processors for a hybrid biological and physical-chemical waste recycling system. The system would be capable of reclaiming from inedible plant biomass, human metabolic waste, and gray water those components needed for plant growth (carbon dioxide, water, and inorganic salts), while eliminating noxious compounds and maximizing system closure. We will colaborate with AMES Research Center (ARC), Johnson Space Center (JSC), and academia, to design a functional biological-based waste processing system that could be integrated with the planned Human Rated Test Facility (HRTF) at JSC.
Technical Paper

Stability and reliability of biological reactors

1997-07-01
972549
Bioregenerative resource recovery components for Advanced Life Support systems will need to be reliable and stable for long duration space travel. Since 1989, bioregenerative life support research at the ALS Breadboard Project has examined processing of inedible crop residues in bioreactors for recovery of nutrients for replenishment of crop hydroponic solutions. Bioreactor operation has been reliable as demonstrated by continuous operation for up to 418 days with long periods of steady state conditions. Bioreactors have demonstrated stability following unplanned, non-lethal perturbations in pH, temperature, dissolved oxygen, and inedible residue supply. In each instance, a rapid return to steady state conditions was observed.
Technical Paper

Testbed for Determining the Filtering Capacities of COTS Adsorbents

2007-07-09
2007-01-3137
A lab-scale testbed for screening and characterizing the chemical specificity of commercial “off-the-shelf” (COTS) polymer adsorbents was built and tested. COTS polymer adsorbents are suitable candidates for future trace contaminant (TC) control technologies. Regenerable adsorbents could reduce overall TC control system mass and volume by minimizing the amounts of consumables to be resupplied and stored. However, the chemical specificity of these COTS adsorbents for non-methane volatile organic compounds (NMVOCs) (e.g., methanol, ethanol, dichloromethane, acetone, etc) commonly found in spacecraft is unknown. Furthermore, the effect of humidity on their filtering capacity is not well characterized. The testbed, composed of a humidifier, an incubator, and a gas generator, delivers NMVOC gas streams to conditioned sorbent tubes.
Technical Paper

Volatile Organic Compound Analysis (VOCA): A System for Evaluating Atmospheric Contaminants on Plant Growth

2005-07-11
2005-01-2771
A set of contained environment chambers have been designed to study the effects of Volatile Organic Compounds (VOCs) on plant growth and development. The Volatile Organic Compound Analysis (VOCA) system consists of six Lexan chambers, each with independent VOC monitoring and control capacities. The VOC exposure chambers are located within a larger controlled environment chamber (CEC) which provides a common air temperature, photoperiod, and light control. Relative humidity, CO2 concentration, and VOC concentration of the atmosphere are independently controlled in each VOCA exposure chambers. CO2, air temperature, relative humidity and PPF are continuously monitored with software developed using IOControl™ and IODisplay™.
X