Standard

Aircraft Lightning Direct Effects Certification

2008-03-26
CURRENT
ARP5577
This document provides guidance for a means of showing compliance with regulations for protection against lightning direct effects for aircraft of conventional design, as well as for those involving advanced composite structures or other new technologies. This guidance also applies to those aspects of aircraft systems and components not addressed in the regulations covering the protection of electrical/electronic systems (for example, FAR/JAR xx.1316) or fuel systems (for example, xx.954). The guidance provided in this document applies to initial designs as well as modifications.
Standard

Aircraft Lightning Zone

2012-09-28
HISTORICAL
ARP5414A
This SAE Aerospace Recommended Practice (ARP) defines lightning strike zones and provides guidelines for locating them on particular aircraft, together with examples. The zone definitions and location guidelines described herein are applicable to Parts 23, 25, 27, and 29 aircraft. The zone location guidelines and examples are representative of in-flight lightning exposures.
Standard

Aircraft Lightning Zone

2018-12-05
CURRENT
ARP5414B
This SAE Aerospace Recommended Practice (ARP) defines lightning strike zones and provides guidelines for locating them on particular aircraft, together with examples. The zone definitions and location guidelines described herein are applicable to Parts 23, 25, 27, and 29 aircraft. The zone location guidelines and examples are representative of in-flight lightning exposures.
Standard

Aircraft Lightning Zoning

1999-12-01
HISTORICAL
ARP5414
This SAE Aerospace Recommended Practice (ARP) defines lightning strike zones and provides guidelines for locating them on particular aircraft, together with examples. The zone definitions and location guidelines described herein are applicable to Parts 23, 25, 27, and 29 aircraft. The zone location guidelines and examples are representative of in-flight lightning exposures.
Standard

Transport Airplane Fuel System Lightning Protection

2023-04-04
CURRENT
ARP6205
This document is intended to be a user’s manual to AC 25.954-1 on acceptable means of compliance for applicants with regards to § 25.954 at Amendment 25-146 and to encourage a consistent approach to be applied across industry. This document is also intended to be a user’s manual to AMC 25.954 on acceptable means of compliance for applicants with regards to EASA CS 25.954 at Amendment 26. The FAA Advisory Circular (AC) and the EASA Acceptable Means of Compliance (AMC) documents appear to provide equivalent guidance, using identical wording in most sections. Applicants should coordinate with their certifying authority to ensure that their proposed approach is acceptable, and the means of compliance and compliance data planned are sufficient for certification. It is recommended that the applicant verify that use of the guidance in this document is acceptable to their certifying authority.
Standard

User's Manual for Certification of Aircraft Electrical/Electronic Systems for the Indirect Effects of Lightning

2020-04-21
WIP
ARP5415C
This ARP provides detailed information, guidance, and methods in support of the Federal Aviation Administration (FAA) Advisory Circular (AC) 20-136. AC 20-136 provides a means, but not the only means, for demonstrating compliance with Title 14 of the Code of Federal Regulations (14 CFR) 23.1306 (Amendment 23-61), 23.2515 (Amendment 23-64), 25.1316, 27.1316, and 29.1316. It is also intended for this ARP to provide the same information, guidance, and methods, to the European Aviation Safety Agency (EASA) certification specifications CS 23.1306 (Amendment 23/4), 23.2515 (Amendment 23/5), 25.1316, 27.1316, and 29.1316, and associated Acceptable Means of Compliance (AMC) 20-136.
Standard

User's Manual for Certification of Aircraft Electrical/Electronic Systems for the Indirect Effects of Lightning

2008-02-16
HISTORICAL
ARP5415A
This user's manual provides additional information and references relevant to identifying: (1) acceptance criteria for the indirect effects of lightning compliance approaches, (2) verification (analysis and test) methods including those associated with multiple stroke and multiple burst and (3) recommended design options to optimize needed system immunity to lightning indirect effects. Equipment hazards addressed include those due to the indirect effects on equipment mounted on the aircraft exterior and equipment located within the aircraft interior as well as all associated interconnecting wiring. This document has specific application toward those topics and subsystems addressed in ARP5413 but also provides additional guidelines in the application of those tests identified in DO-160/ED-14, Section 22.
Standard

User’s Manual for Certification of Aircraft Electrical/Electronic Systems for the Indirect Effects of Lightning

2020-03-05
CURRENT
ARP5415B
This ARP provides detailed information, guidance, and methods in support of the Federal Aviation Administration (FAA) Advisory Circular (AC) 20-136. AC 20-136 provides a means, but not the only means, for demonstrating compliance with Title 14 of the Code of Federal Regulations (14 CFR) 23.1306 (Amendment 23-61), 23.2515 (Amendment 23-64), 25.1316, 27.1316, and 29.1316. It is also intended for this ARP to provide the same information, guidance, and methods, to the European Aviation Safety Agency (EASA) certification specifications CS 23.1306 (Amendment 23/4), 23.2515 (Amendment 23/5), 25.1316, 27.1316, and 29.1316, and associated Acceptable Means of Compliance (AMC) 20-136.
Standard

User’s Manual for Certification of Aircraft Electrical/Electronic Systems for the Indirect Effects of Lightning

2001-08-01
HISTORICAL
ARP5415
This user's manual provides additional information and references relevant to identifying: (1) acceptance criteria for the indirect effects of lightning compliance approaches, (2) verification (analysis and test) methods including those associated with multiple stroke and multiple burst and (3) recommended design options to optimize needed system immunity to lightning indirect effects. Equipment hazards addressed include those due to the indirect effects on equipment mounted on the aircraft exterior and equipment located within the aircraft interior as well as all associated interconnecting wiring. This document has specific application toward those topics and subsystems addressed in ARP5413 but also provides additional guidelines in the application of those tests identified in DO-160/ED-14, Section 22.