Auxiliary Two Conductor Electrical Power Connector for Truck-Trailer High Power Jumper Cable

2015-11-24
J3082_201511
This SAE Standard provides the minimum requirements for high power two conductor jumper cable plug and receptacle for truck-trailer jumper cable systems. It includes the test procedures, design, and performance requirements. This document covers receptacles rated at more than 30A (Ampere) up to and including 150A and is intended for a single circuit with one power conductor and one common return conductor. Single conductor high current connectors are not recommended for future designs because of inadequate ground return through 5th wheel / king pin. Cable size selection is to be made by the vehicle OEM for specific applications and the specific voltage drop requirements of those applications. This SAE Standard covers two variants of high power two conductor connections: a heavy duty version with horizontally aligned pins, typically for lift-gate battery charging and a medium duty version with vertically aligned pins: typically for loads such as power tarpaulins.
Standard

Auxiliary Two-Conductor Electrical Power Connector for Truck-Trailer High-Power Jumper Cable

2019-08-20
J3082_201908
This SAE Standard provides the minimum requirements for high-power, two-conductor jumper cable plug and receptacle for truck-trailer jumper cable systems. It includes the test procedures, design, and performance requirements. This document covers receptacles rated 12 VDC nominal and at more than 30 A (amperes) up to and including 150 A, and is intended for a single circuit with one power conductor and one common return conductor. Single-conductor high-current connectors are not recommended for future designs because of inadequate ground return through fifth wheel/king pin. Cable size selection is to be made by the vehicle OEM for specific applications and the specific voltage drop requirements of those applications.
Standard

COILED ELECTRICAL CABLE

1993-11-01
J2222_199311
This Draft Technical Report covers the minimum performance and endurance requirements for coiled electrical cables to connect a tractor and trailer and/or trailer to trailer. The purpose of this Draft Technical Report is to give the technical community the opportunity to review, comment on, and use the Draft Technical Report prior to its final approval by SAE. This document shall have a life span of no more than three years from approval which may not be renewed. This Draft Technical Report represents the current thinking of the sponsoring Technical Committee. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringements arising therefrom, is the sole responsibility of the user. Comments on this Draft are welcome and should be submitted in writing to Secretary, Technical Standards Board, SAE Headquarters, 400 Commonwealth Drive, Warrendale, PA 15096-0001.
Standard

Cable Marking for Circuit Identification in Multi-Voltage Power Distribution Systems

2021-01-13
J3176_202101
This SAE Standard establishes the minimum circuit identification and requirements for Multi-Voltage Power Distribution Systems (MVPDS) for use on trucks and buses. A Multi-Voltage Power Distribution System is one that distributes two or three voltages, up to 60 VDC, to power the controls, instruments, and devices.
Standard

Circuit Breakers

2022-05-26
J553_202205
This SAE Standard defines the test conditions, procedures, and performance requirements for circuit breakers in ratings up to and including 200 A. The document includes automatic reset, modified reset, and manually reset types of circuit breakers for 12 VDC, 24 VDC, and 48 VDC electrical systems. Some circuit breakers may have dual voltage ratings (AC and DC); however, this document evaluates DC performance only.
Standard

Circuit Breakers

2004-06-22
J553_200406
This SAE Standard defines the test conditions, procedures, and performance requirements for circuit breakers in ratings up to and including 50 A. The document includes automatic reset, modified reset, and manually reset types of circuit breakers for 12 V and 24 V DC electrical systems. Some circuit breakers may have dual voltage ratings (AC and DC), however, this document evaluates DC performance only.
Standard

Circuit Breakers

2016-07-12
J553_201607
This SAE Standard defines the test conditions, procedures, and performance requirements for circuit breakers in ratings up to and including 200 A. The document includes automatic reset, modified reset, and manually reset types of circuit breakers for 12 V and 24 V DC electrical systems. Some circuit breakers may have dual voltage ratings (AC and DC), however, this document evaluates DC performance only.
Standard

Coiled Electrical Cable - Truck and Bus

2012-10-24
J2222_201210
This SAE Standard establishes the minimum performance and endurance requirements for coiled electrical cables used for hookup between trucks, trailers and dollies. The component standards SAE J2394 (replaced SAE J1067) for cable and SAE J560 for connectors must be consulted to determine the complete performance and endurance requirements of the system. Related TMC Recommended Practices may be consulted for information associated with selection, installation and inspection of these coiled electrical cables. This document is intended to set out requirements for the majority of conditions rather than for specialized applications or environments.
Standard

Coiled Electrical Cable - Truck and Bus

2018-02-15
J2222_201802
This SAE Standard establishes the minimum performance and endurance requirements for coiled electrical cables used for hookup between trucks, trailers and dollies. The component standards SAE J2394 (replaced SAE J1067) for cable and SAE J560 for connectors must be consulted to determine the complete performance and endurance requirements of the system. Related TMC Recommended Practices may be consulted for information associated with selection, installation and inspection of these coiled electrical cables. This document is intended to set out requirements for the majority of conditions rather than for specialized applications or environments.
Standard

Coiled Electrical Cable—Truck and Bus

2007-06-12
J2222_200706
This SAE Standard establishes the minimum performance and endurance requirements for coiled electrical cables used for hookup between trucks, trailers and dollies. The component standards SAE J2394 (replaced SAE J1067) for cable and SAE J560 for connectors must be consulted to determine the complete performance and endurance requirements of the system. Related TMC Recommended Practices may be consulted for information associated with selection, installation and inspection of these coiled electrical cables. This document is intended to set out requirements for the majority of conditions rather than for specialized applications or environments.
Standard

Combination 11 Conductors and 2 Pairs ECBS Cable

2018-06-03
J2742_201806
This SAE standard establishes the minimum construction and performance requirements for a combination cable consisting of 11 conductors and 2 twisted pairs for use on trucks, trailers, and dollies in conjunction with SAE J2691. (15 pole connectors.) The cable includes both power and unjacketed SAE J1939-15 paired signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

Combination 11 Conductors and 4 Pairs ECBS Cable

2013-04-09
J2742_201304
This SAE standard establishes the minimum construction and performance requirements for a combination cable consisting of 11 conductors and 4 twisted pairs for use on trucks, trailers, and dollies in conjunction with SAEJ2691. (15 pole connectors.) The cable includes both power and unjacketed SAE J1939-15 paired signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

Heavy Duty High Speed Datalink Connector

2020-01-08
J2839_202001
This SAE Recommended Practice defines the performance requirements, size and mating interfaces for M12 style 4 and 5 pole Heavy Duty High Speed Datalink connection systems, and applies to both cable-to-cable and cable-to-device connectors.
Standard

Heavy Duty High Speed Datalink Connector

2010-02-18
J2839_201002
This SAE Recommended Practice defines the performance requirements, size and mating interfaces for M12 style 4 and 5 pole Heavy Duty High Speed Datalink connection systems, and applies to both cable-to-cable and cable-to-device connectors.
Standard

Heavy Duty High Speed Datalink Connector

2015-07-08
J2839_201507
This SAE Recommended Practice defines the performance requirements, size and mating interfaces for M12 style 4 and 5 pole Heavy Duty High Speed Datalink connection systems, and applies to both cable-to-cable and cable-to-device connectors.
Standard

Heavy Duty Truck and Bus Electrical Circuit Performance Requirement for 12/24-Volt Electric Starter Motors

2024-03-22
J3053_202403
The recommended practice describes a design standard that defines the maximum recommended voltage drop of the starting motor main circuits, as well as control system circuits, for 12/24-V starter systems. The battery technologies used in developing this document include the flooded lead acid, gel cell, and AGM. Starting systems supported by NiCd, Lithium Ion, NiZn, etc., or Ultracaps are not included in this document. This document is not intended to be updated or modified to include starter motors rated at voltages above the nominal 24-V electrical system. The starter is basically an electrical-to-mechanical power converter. If you double the available battery power in, you double the peak mechanical power out and double the heat losses. This means that we have to pay special attention to how battery power changes when we change the battery voltage and the effects it may have in overpowering the cranking system.