CFC-12 (R-12) EXTRACTION EQUIPMENT FOR MOBILE AUTOMOTIVE AIR-CONDITIONING SYSTEMS

1992-06-01
HISTORICAL
J2209_199206
The purpose of this SAE Recommended Practice is to provide equipment specifications for CFC-12 (R-12) recovery for return to a refrigerant reclamation facility that will process it to ARI standard 700-88 as a minimum (Air Conditioning and Refrigerant Institute). It is not acceptable that the refrigerant removed from a mobile air-conditioning system, with this equipment, be directly returned to a mobile air-conditioning system. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar R-12 systems.
Standard

CFC-12 (R-12) Refrigerant Recovery Equipment for Mobile Automotive Air-Conditioning Systems

1999-02-01
HISTORICAL
J2209_199902
The purpose of this SAE Standard is to provide equipment specifications for CFC-12 (R-12) recovery for return to a refrigerant reclamation facility that will process it to the appropriate ARI Standard (Air Conditioning and Refrigerant Institute) or allow for recycling of the recovered refrigerant in equipment that is certified to meet the requirements of SAE J1991. Under the existing rule, the U.S. EPA requires refrigerant removed from a mobile air-conditioning (A/C) system using recovery equipment certified to meet SAE J2209 can only be recycled using equipment meeting SAE J1991 that is owned by the same company or individual. It is not acceptable that the refrigerant removed from a mobile A/C system, with this equipment, be directly returned to a mobile A/C system. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar CFC-12 (R-12) systems.
Standard

EXTRACTION AND RECYCLE EQUIPMENT FOR MOBILE AUTOMOTIVE AIR-CONDITIONING SYSTEMS

1989-10-01
HISTORICAL
J1990_198910
The purpose of this document is to provide equipment specifications for CFC-12 (R-12) recycling and/or recovery, and recharging systems. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar CFC-12 systems. Systems used on mobile vehicles for refrigerated cargo that have hermetically sealed systems are not covered in this document.
Standard

EXTRACTION AND RECYCLE EQUIPMENT FOR MOBILE AUTOMOTIVE AIR-CONDITIONING SYSTEMS

1992-03-01
HISTORICAL
J1990_199203
The purpose of this SAE Standard is to provide equipment specifications for CFC-12 (R-12) recycling equipment. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar CFC-12 air-conditioning systems. Systems used on mobile vehicles for refrigerated cargo that have hermetically sealed systems are not covered in this document. The equipment in this document is intended for use with refrigerant that has been directly removed from, and intended to be returned to, a mobile air-conditioning system. Should other revisions due to operational or technical requirements occur, this document may be amended.
Standard

HFC-134a (R-134a) Recovery/Recycling Equipment and Recovery/Recycling/Recharging for Mobile Air-Conditioning Systems

2006-12-05
HISTORICAL
J2788_200612
The purpose of this SAE Standard is to establish the specific minimum equipment performance requirements for recovery and recycling of HFC-134a that has been directly removed from, and is intended for reuse in, mobile air-conditioning (A/C) systems. It also is intended to establish requirements for equipment used to recharge HFC-134a to an accuracy level that meets Section 9 of this document and SAE J2099. The requirements apply to the following types of service equipment and their specific applications. a Recovery/Recycling Equipment, b Recovery/Recycling – Refrigerant Charging, c Refrigerant Recharging Equipment Only.
Standard

PASSENGER CAR BACKLIGHT DEFOGGING SYSTEM

1999-02-01
HISTORICAL
J953_199902
The scope of this SAE Recommended Practice is to establish uniform test procedures for passenger cars, to determine whether the system is defined as a defroster or defogger, and to establish minimum performance requirements for each system. A defroster for purposes of this practice is a system which will remove moisture and/or frost from the interior surface of the backlight at −18 °C. A defogger is a system which will remove moisture and/or fog from the interior surface of the backlight at 4 °C. The test procedure is intended to simulate actual conditions by utilizing either a cold room with an appropriate device to introduce air flow over the backlight or a sufficiently large wind tunnel with ambient temperature control. The test procedure and the minimum performance requirements are based on currently available engineering data.
Standard

PASSENGER CAR BACKLIGHT DEFOGGING SYSTEM

1984-06-01
HISTORICAL
J953_198406
The scope of this SAE Recommended Practice is to establish uniform test procedures for passenger cars, to determine whether the system is defined as a defroster or defogger, and to establish minimum performance requirements for each system. A defroster for purposes of this practice is a system which will remove moisture and/or frost from the interior surface of the backlight at 0°F (−18°C). A defogger is a system which will remove moisture and/or fog from the interior surface of the backlight at 40°F (4°C). The test procedure is intended to simulate actual conditions by utilizing either a cold room with an appropriate device to introduce air flow over the backlight or a sufficiently large wind tunnel with ambient temperature control. The test procedure and the minimum performance requirements are based on currently available engineering data.
Standard

PERFORMANCE CRITERIA FOR ELECTRONIC REFRIGERANT LEAK DETECTORS

1995-08-01
HISTORICAL
J1627_199508
This SAE Standard applies to electronic probe-type leak detectors used to service motor vehicle passenger compartment air-conditioning systems. This document does not address any safety issues concerning their design or use.
Standard

Procedure Retrofitting CFC-12 (R-12) Mobile Air-Conditioning Systems to HFC-134a (R-134a)

1998-11-01
HISTORICAL
J1661_199811
The purpose of this SAE Recommended Practice is to provide a service procedure for retrofitting a CFC-12 (R-12) system to HFC-134a (R-134a) while preserving performance and integrity of the air-conditioning (A/C) system. The steps outlined in this procedure are complete when combined with good service practices and the vehicle manufacturer's recommendations (if available) for retrofitting their models. Separate service equipment, for CFC-12 (R-12) and HFC-134a (R-134a), including refrigerant recovery/recycle (R/R), service manifolds, vacuum pumps, and charging equipment shall be used to preserve the purity of the refrigerants and the mobile A/C systems. This procedure will minimize release of refrigerant to the atmosphere, and will preserve the integrity of the recycled CFC-12 (R-12) and HFC-134a (R-134a) supplies. This document applies to A/C systems used to cool the passenger compartment of automobiles, light trucks, and other vehicles with similar CFC-12 (R-12) systems.
Standard

Procedure for Certification that Requirements for Mobile Air Conditioning System Components, Service Equipment, and Service Technician Training Meet SAE J Standards

2012-01-12
HISTORICAL
J2911_201201
This SAE Standard provides manufacturers, testing facilities and providers of technician training with a procedure for certifying compliance with the appropriate standards. Manufacturers who advertise their products as Certified to an SAE J standard shall follow this procedure. Certification of a product is voluntary, however, this certification process is mandatory for those advertising meeting SAE Standard(s) requirements. Only certifying to this standard allows those claiming compliance to advertise that their product (unit), component, or service meets all requirements of the specific SAE standard. Certification of compliance to this and the appropriate standard and use of the SAE label on the product shall only be permitted after all the required information has been submitted to SAE International and it has been posted on the SAE web site.
Standard

Procedure for Certification that Requirements for Mobile Air Conditioning System Components, Service Equipment, and Service Technician Training Meet SAE J Standards

2011-02-04
HISTORICAL
J2911_201102
This SAE Standard provides manufacturers, testing facilities and providers of technician training with a procedure for certifying compliance with the appropriate standards. Manufacturers who advertise their products as Certified to an SAE J standard shall follow this procedure. Certification of a product is voluntary, however, this certification process is mandatory for those advertising meeting SAE Standard(s) requirements. Only certifying to this standard allows those claiming compliance to advertise that their product (unit), component, or service meets all requirements of the specific SAE standard. Certification of compliance to this and the appropriate standard and use of the SAE label on the product shall only be permitted after all the required information has been submitted to SAE International and it has been posted on the SAE web site.
Standard

Procedure for Certification that Requirements for Mobile Air Conditioning System Components, Service Equipment, and Service Technician Training Meet SAE J Standards

2020-02-03
CURRENT
J2911_202002
This SAE standard provides manufacturers/marketers, testing facilities, and providers of technician training with a procedure for certifying compliance with the applicable standard. Manufacturers/marketers or sellers who advertise their products as certified to an SAE J standard shall follow this procedure. Certification of a product is voluntary; however, this certification process is mandatory for those advertising meeting SAE standard(s) requirements. Only certifying to this standard allows those claiming compliance to advertise that their product (unit), component, or service technician training meets all requirements of the applicable SAE standard. Certification of compliance to this and the appropriate standard and use of the SAE label on the product shall only be permitted after all the required information has been submitted to SAE International and it has been posted on the SAE website.
Standard

Procedure for Certification that Requirements for Mobile Air Conditioning System Components, Service Equipment, and Service Technician Training Meet SAE J Standards

2017-11-13
HISTORICAL
J2911_201711
This SAE Standard provides manufacturers/marketers, testing facilities and providers of technician training with a procedure for certifying compliance with the applicable standard. Manufacturers/marketers or sellers who advertise their products as Certified to an SAE J standard shall follow this procedure. Certification of a product is voluntary; however, this certification process is mandatory for those advertising meeting SAE Standard(s) requirements. Only certifying to this standard allows those claiming compliance to advertise that their product (unit), component, or service technician training meets all requirements of the applicable SAE standard. Certification of compliance to this and the appropriate standard and use of the SAE label on the product shall only be permitted after all the required information has been submitted to SAE International and it has been posted on the SAE web site.
Standard

Procedure for Certification that Requirements for Mobile Air Conditioning System Components, Service Equipment, and Service Technician Training Meet SAE J Standards

2016-12-02
HISTORICAL
J2911_201612
This SAE Standard provides manufacturers, testing facilities and providers of technician training with a procedure for certifying compliance with the applicable standard. Manufacturers or seller who advertise their products as Certified to an SAE J standard shall follow this procedure. Certification of a product is voluntary; however, this certification process is mandatory for those advertising meeting SAE Standard(s) requirements. Only certifying to this standard allows those claiming compliance to advertise that their product (unit), component, or service technician training meets all requirements of the applicable SAE standard. Certification of compliance to this and the appropriate standard and use of the SAE label on the product shall only be permitted after all the required information has been submitted to SAE International and it has been posted on the SAE web site.
Standard

Procedure for Certification that Requirements for Mobile Air Conditioning System Components, Service Equipment, and Service Technician Training Meet SAE J Standards

2013-01-14
HISTORICAL
J2911_201301
This SAE Standard provides manufacturers, testing facilities and providers of technician training with a procedure for certifying compliance with the appropriate standards. Manufacturers or seller who advertise their products as Certified to an SAE J standard shall follow this procedure. Certification of a product is voluntary; however, this certification process is mandatory for those advertising meeting SAE Standard(s) requirements. Only certifying to this standard allows those claiming compliance to advertise that their product (unit), component, or service meets all requirements of the specific SAE standard. Certification of compliance to this and the appropriate standard and use of the SAE label on the product shall only be permitted after all the required information has been submitted to SAE International and it has been posted on the SAE web site.