Refine Your Search

Topic

Search Results

Technical Paper

Data-Driven Framework for Fuel Efficiency Improvement in Extended Range Electric Vehicle Used in Package Delivery Applications

2020-04-14
2020-01-0589
Extended range electric vehicles (EREVs) are a potential solution for fossil fuel usage mitigation and on-road emissions reduction. The use of EREVs can be shown to yield significant fuel economy improvements when proper energy management strategies (EMSs) are employed. However, many in-use EREVs achieve only moderate fuel reduction compared to conventional vehicles due to the fact that their EMS is far from optimal. This paper focuses on in-use rule-based EMSs to improve the fuel efficiency of EREV last-mile delivery vehicles equipped with two-way Vehicle-to-Could (V2C) connectivity. The method uses previous vehicle data collected on actual delivery routes and machine learning methods to improve the fuel economy of future routes. The paper first introduces the main challenges of the project, such as inherent uncertainty in human driver behavior and in the roadway environment. Then, the framework of our practical physics-model guided data-driven approach is introduced.
Journal Article

A Bayesian Approach to Cross-Validation in Pedestrian Accident Reconstruction

2011-04-12
2011-01-0290
In statistical modeling, cross-validation refers to the practice of fitting a model with part of the available data, and then using predictions of the unused data to test and improve the fitted model. In accident reconstruction, cross-validation is possible when two different measurements can be used to estimate the same accident feature, such as when measured skidmark length and pedestrian throw distance each provide an estimate of impact speed. In this case a Bayesian cross-validation can be carried out by (1) using one measurement and Bayes theorem to compute a posterior distribution for the impact speed, (2) using this posterior distribution to compute a predictive distribution for the second measurement, and then (3) comparing the actual second measurement to this predictive distribution. An actual measurement falling in an extreme tail of the predictive distribution suggests a weakness in the assumptions governing the reconstruction.
Technical Paper

Subjective Perception of Thermal and Physical Comfort in Three Liquid Cooling Garments

2009-07-12
2009-01-2516
The subjective aspects of comfort in three different cooling garments, the MACS-Delphi, Russian Orlan, and LCVG were evaluated. Six subjects (4 males and 2 females) were tested in separate sessions in each garment and in one of two environmental chamber conditions: 24°C and 35°C. Subjects followed a staged exercise/rest protocol with different levels of physical exertion at different stages. Thermal comfort and heat perception were assessed by ratings on visual analog scales. Ratings of physical comfort of the garment and also garment flexibility in positions simulating movements during planetary exploration were also obtained. The findings indicated that both overall thermal comfort and head thermal comfort were rated highest in the MACS-Delphi at 24°C. The Orlan was rated lowest on physical comfort and less flexible in different body positions.
Technical Paper

The Advanced Design of a Liquid Cooling Garment Through Long-Term Research: Implications of the Test Results on Three Different Garments

2009-07-12
2009-01-2517
The most recent goal of our research program was to identify the optimal features of each of three garments to maintain core temperature and comfort under intensive physical exertion. Four males and 2 females between the ages of 22 and 46 participated in this study. The garments evaluated were the MACS-Delphi, Russian Orlan, and NASA LCVG. Subjects were tested on different days in 2 different environmental chamber temperature/humidity conditions (24°C/H∼28%; 35°C/H∼20%). Each session consisted of stages of treadmill walking/running (250W to 700W at different stages) and rest. In general, the findings showed few consistent differences among the garments. The MACS-Delphi was better able to maintain subjects within a skin and core temperature comfort zone than was evident in the other garments as indicated by a lesser fluctuation in temperatures across physical exertion levels.
Technical Paper

Particle and Gaseous Emission Characteristics of a Formula SAE Race Car Engine

2009-04-20
2009-01-1400
The focus of this work was the physical characterization of exhaust aerosol from the University of Minnesota Formula SAE team's engine. This was done using two competition fuels, 100 octane race fuel and E85. Three engine conditions were evaluated: 6000 RPM 75% throttle, 8000 RPM 50% throttle, and 8000 RPM 100% throttle. Dilute emissions were characterized using a Scanning Mobility Particle Sizer (SMPS) and a Condensation Particle Counter (CPC). E85 fuel produced more power and had lower particulate matter emissions at all test conditions, but more fuel was consumed.
Technical Paper

Off-shoring EMS and the Barrier of Test-in-Reliability

2008-10-07
2008-01-2712
The history of off-road equipment manufacturing has been based on proven designs and long times between model updates. In sharp contrast with this strategy is the electronic manufacturing services (EMS) industry. The EMS industry is driven by the larger consumer product industry's continuing pressure for lower costs. Because of this, EMS tools, processes, and practices have evolved to support rapid technology and component changes. However the increasing consumer demand for features like better user-interfaces, more efficient fuel consumption, and the desire for increased operational controls in equipment have forced the off-road industry to increase the frequency of product updates to meet customers' needs. Equipment manufacturers make running changes leading to a “Learning-by-doing” development and manufacturing process. But rapid changes sometimes have an unpredictable impact on the reliability of the final product.
Technical Paper

Trade Study of an Exploration Cooling Garment

2008-06-29
2008-01-1994
A trade study was conducted with a goal to develop relatively high TRL design concepts for an Exploration Cooling Garment (ExCG) that can accommodate larger metabolic loads and maintain physiological limits of the crewmembers health and work efficiency during all phases of exploration missions without hindering mobility. Effective personal cooling through use of an ExCG is critical in achieving safe and efficient missions. Crew thermoregulation not only impacts comfort during suited operations but also directly affects human performance. Since the ExCG is intimately worn and interfaces with comfort items, it is also critical to overall crewmember physical comfort. Both thermal and physical comfort are essential for the long term, continuous wear expected of the ExCG.
Technical Paper

Cooling and Thermal Control Strategies in the Space Suit for Routine and Emergency Situations

2008-06-29
2008-01-1993
A series of demonstration studies were conducted with the aim of better understanding how to regulate body heat and thus enhance thermal comfort of astronauts during EVA requiring intensive physical exertion. The first study evaluated body zone heat transfer under different cooling temperatures in a liquid cooling garment (LCG), confirming the effectiveness of areas with high density tissue. The second study evaluated different configurations of hoods and neck scarves to maximize heat extraction from these key areas for heat release. The third study explored the possibility of regulating body heat by control of the water temperature circulating through selected body zones in the LCG, or blocking heat dissipation from particular body areas. The potential of heat insertion/removal from the head, hands, and feet to stabilize body comfort was evaluated in terms of the ability to advance this heat current “highway” from the core.
Technical Paper

Person to Person Biological Heat Bypass During EVA Emergencies

2007-07-09
2007-01-3209
During EVA and other extreme environments, mutual human support is sometimes the last way to survive when there is a failure of the life support equipment. The possibility to transfer a warming fluid from one individual to another to increase heat and support the thermal balance of the individual with system failure was assessed. The following analog scenarios were considered: 1. one subject has a cooling system that is not working well and already has a body heat deficit equal to 100-120 kcal and a finger temperature decline to 26-27ºC, the other subject is at comfort level; 2. one subject is overcooled due to system failure and the other is mildly overheated. Preliminary findings showed promise in using such thermal sharing tactics to extend the time duration of survival in extreme situations when there is an increased metabolic rate in the donor.
Technical Paper

Comparing Measurements of Carbon in Diesel Exhaust Aerosols Using the Aethalometer, NIOSH Method 5040, and SMPS

2007-04-16
2007-01-0334
Combustion aerosols consist mainly of elemental and organic carbon (EC and OC). Since EC strongly absorbs light and thus affects atmospheric visibility and radiation balance, there is great interest in its measurement. To this end, the National Institute for Occupational Safety and Health (NIOSH) published a standard method to determine the mass of EC and OC on filter samples. Another common method of measuring carbon in aerosols is the aethalometer, which uses light extinction to measure “black carbon” or BC, which is considered to approximate EC. A third method sometimes used for estimating carbon in submicron combustion aerosols, is to measure particle size distributions using a scanning mobility particle sizer (SMPS) and calculate mass using the assumptions that the particles are spherical, carbonaceous and of known density.
Technical Paper

Informativeness of the Finger Temperature/Heat Flux as an Index of Human Thermal Status Under Local Cold Influences

2006-07-17
2006-01-2237
Introduction Human thermoregulation during EVA remains a challenge. The establishment of a high correlation between the thermal status of the fingers and the heat surplus/deficit in the body provides an index with potential to more effectively monitor and control the astronaut’s thermal status. This series of studies evaluated the changes in finger temperature (Tfing) trajectories in conditions relevant to EVA. Methods In different experiments, subjects were donned in a liquid cooling/warming garment (LCWG) that covered the full body surface except for the face and hands; they wore either a physiologically designed warming glove or the Phase VI glove. The experimental protocols were as follows: imposition of temperature differences in the left and right gloves; different thermal insulation levels of the gloves; sequential grasping of a highly cold rail in different glove conditions; placement of the finger thermistor on different sites of the finger.
Technical Paper

Effect of Local Hand Thermal Insulation on Total and Local Comfort Under Different Levels of Body Heat Deficit

2005-07-11
2005-01-2977
Introduction: There are contradictory opinions regarding the contribution of local hand thermal insulation to support local and total comfort during extravehicular activity (EVA). Instead of a local correction by means of thermal insulation on the periphery of the body to prevent heat dissipation, it may be optimal to prevent heat dissipation from the body core. To examine such a concept, the effects of different insulation levels on the left and right hands on the heat flux and temperature mosaic on the hands was measured. These variables were assessed in relation to the level of heat deficit forming in the core organs and tissues. Methods: Six subjects (4 males, 2 females) were donned in a liquid cooling/warming garment (LCWG) that totally covered the body surface except for the face. Participants wore the Phase VI space gloves including the entire micrometeoroid garment (TMG) on the left hand, and the glove without the TMG on the right hand.
Technical Paper

Comparison of Shortened and Standard Liquid Cooling Garments to Provide Physiological and Subjective Comfort During EVA

2004-07-19
2004-01-2347
The shortened liquid cooling/warming garment (SLCWG) developed by the University of Minnesota group was compared with the standard NASA liquid cooling/ventilating garment (LCVG) garment during physical exertion in comfort (24°C) and hot (35°C) chamber environments. In both environmental conditions, the SLCWG was just as effective as the LCVG in maintaining rectal temperature (Tre) in a thermal comfort range; sweat production on the face was less; and subjective perception of overall and local body comfort was higher. The findings indicate that the SLCWG produces the same or greater comfort level as that achieved with the LCVG's total coverage of the body surface.
Technical Paper

An Advanced Physiological Based Shortened Liquid Cooling/Warming Garment for Comfort Management in Routine and Emergency EVA

2002-07-15
2002-01-2413
The focus of this research is on the development of a more energy efficient shortened liquid cooling/warming garment (LCWG) based on physiological principles comparing the efficacy of heat transfer of different body zones; the capability of blood to deliver heat; individual muscle and fat body composition as a basis for individual thermal profiles to customize the zonal involvement of the garment; and the development of shunts to minimize or redirect the cooling/warming loop for different environmental conditions, physical activity levels, and emergency situations. The total length of tubing in the LCWG is approximately 35% less, and the weight decreased by 45% compared to the LCVG currently used in space.
Technical Paper

Comfort Management in Rest and Exercise Conditions in an Innovative Shortened Liquid Cooling/Warming Garment

2002-07-15
2002-01-2411
Comfort management in extreme environments is complex, requiring temperature stabilization of the body core and distal parts of the extremities. Examination of the capability of body zones to absorb and release heat can facilitate a solution to this problem. Using an experimental shortened liquid cooling/warming garment (LCWG), heat transfer effectiveness of different body zone combinations was assessed in rest and exercise conditions, at different levels of body heat deficit and intensities of physical exertion. Comfort stabilization in terms of minimum changes in core (Tc) and finger (Tfing) temperatures was achieved in exercise (200-400 W) at 18-22°C inlet water temperature in the following zonal combination: a portion of the torso, the internal thigh area covering the femoral artery, the forearm, neck, and part of the head.
Technical Paper

Single-Stage Dilution Tunnel Performance

2001-03-05
2001-01-0201
A one-stage dilution tunnel has been developed to sample and dilute diesel exhaust. The tunnel has the capability of simulating many aspects of the atmospheric dilution process. The dilution rate and overall dilution ratio, temperature, relative humidity, and residence time in the tunnel, as well as residence time and temperature in the transfer line between the tunnel and exhaust sampling point may be varied. In this work we studied the influence of the exhaust transfer line, tunnel residence time, and dilution air temperature on the exhaust particle size distribution. The influences of fuel sulfur content on the size distribution and on the sensitivity of the size distribution to dilution and sampling conditions were also examined. We do not suggest an optimum dilution scheme, but do identify critical variables.
Technical Paper

Maximal Conductive Heat Exchange through Different Body Zones in a Liquid Cooling/Warming Space Garment

2000-07-10
2000-01-2255
The maximal capability of several body areas to absorb/release heat by varying the circulating water temperature in different zones of a multi-compartment liquid cooling/warming garment (LCWG) was explored. The goal was to identify the areas that are highly effective to stabilize body comfort, and to use this information for developing a more physiologically-based design of the space suit. The results showed a high capability of the upper compared to the lower body in the conductive heat exchange process. The involvement of the head in this process is still problematic, because there was not a high level of direct heat absorption/release through the cooling/warming hood in the LCWG. Exclusion of the legs but with involvement of the feet in heat exchange had no effect on comfort of the distal parts of the extremities and core body status.
Technical Paper

Augmentation of Blood Circulation to the Fingers through Wrist Warming to Enhance Finger Comfort during Long-Duration EVA

1999-07-12
1999-01-1969
This pilot study explored the effectiveness of local wrist warming as a potential countermeasure for providing finger comfort during extended duration EVA. Four subjects (3 males and 1 female) were evaluated in three different experimental conditions. Two additional body surface and wrist thermal conditions were evaluated on a smaller number of subjects. Wrist warming significantly increased finger temperature in ambient temperature. A clear positive effect to the fingers was evident when total body heat deficit was 30% of basal metabolic heat production in resting conditions. These initial findings indicate that wrist warming has considerable potential for increasing astronaut comfort during EVA while decreasing power requirements.
Technical Paper

The Influence of Dilution Conditions on Diesel Exhaust Particle Size Distribution Measurements

1999-03-01
1999-01-1142
Particle size distribution and number concentration measurements have been made in the diluted exhaust of a medium-duty, turbocharged, aftercooled, direct-injection Diesel engine using a unique variable residence time micro-dilution system that allows systematic variation of dilution and sampling conditions, and a scanning mobility particle sizer (SMPS). The measurements show that the number concentrations in the nanoparticle (Dp < 50 nm) and the ultrafine (Dp < 100 nm) ranges are very sensitive to dilution conditions and fuel sulfur content. Changes in concentration of up to two orders of magnitude have been observed when conditions are varied over the range that might be encountered in typical laboratory dilution systems. For example, at a dilution ratio of 12, dilution temperature of 32 °C, and a residence time of 1000 ms, the number concentrations reach 6 × 108 part.
Technical Paper

Body Surface Temperature Tuning as a Comfort Support System in Space and Other Extreme Environments

1998-07-13
981723
The potential of controlling human body thermal status through monitoring temperature and heat flux indices of the fingers was evaluated. A cooling/warming suit was used that provided a range of uniform and nonuniform temperature regimes on the body surface. Temperature changes on the skin surface changed body comfort significantly but did not affect core temperature. However, under different imposed thermal conditions, peripheral temperature, particularly the fingers, closely followed the thermal conditions either within or on the surface of the body. The fingers appear to have considerable potential as a key site in developing an automatic thermal feedback system in the EVA suit.
X