Refine Your Search

Topic

Search Results

Journal Article

Forward Collision Warning Timing in Near Term Applications

2013-04-08
2013-01-0727
Forward Collision Warning (FCW) is a system intended to warn the driver in order to reduce the number of rear end collisions or reduce the severity of collisions. However, it has the potential to generate driver annoyances and unintended consequences due to high ineffectual (false or unnecessary) alarms with a corresponding reduction in the total system effectiveness. The ineffectual alarm rate is known to be closely associated with the “time to issue warning.” This results in a conflicting set of requirements. The earlier the time the warning is issued, the greater probability of reducing the severity of the impact or eliminating it. However, with an earlier warning time there is a greater chance of ineffectual warning, which could result in significant annoyance, frequent complaints and the driver's disengagement of the FCW. Disengaging the FCW eliminates its potential benefits.
Journal Article

Statistical Considerations for Evaluating Biofidelity, Repeatability, and Reproducibility of ATDs

2013-04-08
2013-01-1249
Reliable testing of a mechanical system requires the procedures used for the evaluation to be repeatable and reproducible. However, it is never possible to exactly repeat or reproduce the tests that are used for evaluation. To overcome this limitation, a statistical evaluation procedure can generally be used. However, most of the statistical procedures use scalar values as input without the ability to handle vectors or time-histories. To overcome these limitations, two numerical/statistical methods for determining if the impact time-history response of a mechanical system is repeatable or reproducible are evaluated and elaborated upon. Such a system could be a vehicle, a biological human surrogate, an Anthropometric Test Device (ATD or dummy), etc. The responses could be sets of time-histories of accelerations, forces, moments, etc., of a component or of the system. The example system evaluated is the BioRID II rear impact dummy.
Journal Article

What's Speed Got To Do With It?

2010-04-12
2010-01-0526
The statistical analysis of vehicle crash accident data is generally problematic. Data from commonly used sources is almost never without error and complete. Consequently, many analyses are contaminated with modeling and system identification errors. In some cases the effect of influential factors such as crash severity (the most significant component being speed) driver behavior prior to the crash, etc. on vehicle and occupant outcome is not adequately addressed. The speed that the vehicle is traveling at the initiation of a crash is a significant contributor to occupant risk. Not incorporating it may make an accident analysis irrelevant; however, despite its importance this information is not included in many of the commonly used crash data bases, such as the Fatality Analysis Reporting System (FARS). Missing speed information can result in potential errors propagating throughout the analysis, unless a method is developed to account for the missing information.
Technical Paper

The Effect of Axial Load in the Tibia on the Response of the 90° Flexed Knee to Blunt Impacts with a Deformable Interface

2004-11-01
2004-22-0003
Lower extremity injuries are a frequent outcome of automotive accidents. While the lower extremity injury criterion is based on fracture of bone, most injuries are of less severity. Recent studies suggest microscopic, occult fractures that have been shown to be precursors of gross bone fractures, may occur in the kneecap (patella) for impacts with rigid and deformable interfaces due to excessive levels of patello-femoral contact pressure. One method of reducing this contact pressure for a 90° flexed knee is to provide a parallel pathway for knee impact loads into the tibial tuberosity. Yet, blunt loads onto the tibial tuberosity can cause posterior drawer motion of the tibia, leading to injury or rupture of the posterior cruciate ligament (PCL). Recently studies have shown that axial loads in the tibia, which are measured during blunt loading on the knee in typical automobile crashes, can induce anterior drawer motion of the tibia and possibly help unload the PCL.
Technical Paper

The Effect of Impact Angle on Knee Tolerance to Rigid Impacts

2003-10-27
2003-22-0001
While the number of deaths from vehicle accidents is declining, probably because of mandatory seat belt laws and air bags, a high frequency of lower extremity injuries from frontal crashes still occurs. For the years 1979-1995 the National Accident Sampling System (NASS) indicates that knee injuries (AIS 1-4) occur in approximately 10% of cases. Patella and femur fractures are the most frequent knee injuries. Current literature suggests that knee fractures occur in seated cadavers for knee impact forces of 7.3 to 21.0 kN. Experimental data shown in a study by Melvin et al. (1975) further suggests that fracture tolerance of the knee may be reduced for an impact directed obliquely to the axis of the femur. The current study hypothesized that the patella is more vulnerable to fracture from an oblique versus an axial impact (directed along the femoral axis), and that the fracture pattern would vary with impact direction.
Technical Paper

An Impact Pulse-Restraint Energy Relationship and Its Applications

2003-03-03
2003-01-0505
This paper presents an energy relationship between vehicle impact pulses and restraint systems and applies the relationship to formulations of response factors for linear and nonlinear restraints. It also applies the relationship to derive optimal impact pulses that minimize occupant response for linear and nonlinear restraints. The relationship offers a new viewpoint to impact pulse optimization and simplifies the process mathematically. In addition, the effects of different vehicle impact pulses on the occupant responses with nonlinear restraints are studied. Finally, concepts of equivalent pulses and equal intensity pulses are presented for nonlinear restraints.
Technical Paper

Effects of Anterior-Posterior Constraint on Injury Patterns in the Human Knee During Tibial-Femoral Joint Loading from Axial Forces through the Tibia

2001-11-01
2001-22-0021
According to the National Accident Sampling System (NASS), 10% of all automobile accident injuries involve the knee. These injuries involve bone fracture and/or “soft tissue” injury. Previous investigators have determined the tibial-femoral (TF) joint failure load for an experimentally constrained human knee at 90° flexion. In these experiments bone fractures have been documented. During TF joint compression, however, anterior motion of the tibia has been noted by others. It was therefore the objectives of this study to document effects of flexion angle and anterior-posterior joint constraint on the nature and severity of knee injury during TF compression loading via axial loads in the tibia. The effect of flexion angle was examined using 10 unconstrained human knees from 5 cadavers aged 73.2±9.4 years.
Technical Paper

The Effect of Loading Rate on the Degree of Acute Injury and Chronic Conditions in the Knee After Blunt Impact

2000-11-01
2000-01-SC20
Lower extremity injuries due to automobile accidents are often overlooked, but can have a profound societal cost. Knee injuries, for example, account for approximately 10% of the total injuries. Fracture of the knee is not only an acute issue but may also have chronic, or long term, consequences. The criterion currently used for evaluation of knee injuries in new automobiles, however, is based on experimental impact data from the 70''s using seated human cadavers. These studies involved various padded and rigid impact interfaces that slightly alter the duration of contact. Based on these data and a simple mathematical model of the femur, it appears fracture tolerance increases as contact duration shortens. In contrast, more recent studies have shown mitigation of gross fractures of the knee itself using padded interfaces. The use of padded interfaces, however, result in coincidental changes in contact duration and knee contact area.
Technical Paper

A Data-Based Model of the Impact Response of the SID

2000-03-06
2000-01-0635
A simple spring-mass model of the impact response of the side impact dummy (SID) is established. The spring and mass constants of the model are established through system identification methodology based on data from impact tests. The tests are performed in laboratory with hydraulically driven impactors impacting the chest and pelvis of the SID. The input data to the model consist of measured contact force or impactor velocity time histories, and the output data are accelerations on the rib, spine, and pelvis of the SID. The established model appears to predict the test results with reasonable accuracy. The main purpose of this study, however, is to use this simple model to carry out parametric studies of the response of the dummy with changing impact parameters, the result of which would be useful in understanding vehicle crash tests using the SID.
Technical Paper

Axial Compressive Load Response of the 90Md Flexed Human Tibiofemoral Joint

1999-10-10
99SC08
National Accident Sampling System (NASS) data, for the years 1993-1995, suggests a high frequency of tibiofemoral joint fractures among automotive accident victims. In addition, the NASS data also suggests that these injuries may be attributable to direct axial loading via the floor pan and/or the foot controls. Hirsch and Sullivan (1965), and Kennedy and Bailey (1968) conducted quasi-static fracture experiments axially compressing human tibiofemoral joints at low rates of loading and low angles of flexion. Hirsch and Sullivan observed a mean fracture load of approximately 8 kN compared to approximately 16 kN in the Kennedy and Bailey study. The current tibiofemoral joint injury criterion used in anthropomorphic dummies is based on Hrisch and Sullivan''s data. The current study involved impact experiments on human tibiofemoral joints (aged 71.4±11.2) directed in a superior direction along the axis of the tibia with the joint flexed 90°.
Technical Paper

Data-Based Models for Spine Acceleration Response of the Side Impact Dummy

1999-10-10
99SC07
The response of the spine acceleration to rib and pelvis acceleration input of the side impact dummy (SID) is modeled using system identification methods. The basis for the modeling is a simplified representation of the SID by a 3-mass, 2-spring system. Based on this spring-mass representation, two types of response models are established. The first is a "gray-box" type with rib/pelvis-spine relationship modeled by Auto Regression with eXogeneous (or eXtra) input (ARX) type system models. The structure of these models is partially based on the spring-mass simplified representation, hence the notion "gray- box." The parameters of these models are identified through linear regression from test data. The second type of models is noted "physical model" here, since it is strictly a state- space form of the equation of motion of the simple spring-mass representation.
Technical Paper

Patellofemoral Joint Fracture Load Prediction Using Physical and Pathological Parameters

1998-02-23
980358
Lower extremity (knee) injury prediction resulting from impact trauma is currently based on a bone fracture criterion derived from experiments on predominantly aged cadavers. Subsequent experimental and theoretical studies indicate that more aged, pathological specimens require higher, not lower, loads to initiate bone fracture. This suggests that a bone fracture criterion based solely on aged specimens may not be representative of the current driving population. In the current study, we sought to determine if cadaver age, physical size, sex, baseline joint pathology, or patellar geometry correlated with fracture load. An analysis was made of data from previous impact experiments conducted on fifteen isolated cadaver knees using a consistent impact protocol. The protocol consisted of sequentially increasing the impact energy with a rigid interface until gross fracture. Gross bone fractures occurred at loads of 6.9±2.0 kN (range 3.2 to 10.6 kN) using this protocol.
Technical Paper

Estimation of Occupant Position from Probability Manifolds of Air Bag Fire-times

1998-02-23
980643
This paper outlines a method for estimating the probablistic nature of airbag crash sensor response and its effect on occupant position. Probability surfaces of airbag fire times are constructed for the impact velocities from 0 to 40 mph. These probability surfaces are obtained by using both frontal offset deformable barrier and frontal rigid barrier crash data. Another probability surface of displacement is constructed to estimate the occupant displacement time history before airbag deployment. This probability surface is constructed by using the initial occupant seating position data and the vehicle impact velocity and deceleration data. In addition, the probability of airbag firing at a given crash velocity is estimated from NASS-CDS, frontal offset and rigid barrier crash data.
Technical Paper

The Influence of Impact Interface on Human Knee Injury: Implications for Instrument Panel Design and the Lower Extremity Injury Criterion

1997-11-12
973327
Injury to the lower extremity during an automotive crash is a significant problem. While the introduction of safety features (i.e. seat belts, air bags) has significantly reduced fatalities, lower extremity injury now occurs more frequently, probably for a variety of reasons. Lower extremity trauma is currently based on a bone fracture criterion derived from human cadaver impact experiments. These impact experiments, conducted in the 1960's and 70's, typically used a rigid impact interface to deliver a blunt insult to the 90° flexed knee. The resulting criterion states that 10 kN is the maximum load allowed at the knee during an automotive crash when certifying new automobiles using anthropomorphic dummies. However, clinical studies suggest that subfracture loading can cause osteochondral microdamage which can progress to a chronic and debilitating joint disease.
Technical Paper

Cavitation During Head Impact

1997-02-24
970390
The effects of stress in brain material was investigated with experimental and computational idealizations of the head. A water-filled cylinder impacted by a free traveling mass serves to give insight into what could happen to the brain during impact. Under an impact of sufficient velocity, cavitation can occur on the cylinder boundary opposite impact. Limited internal vaporization of the fluid may also occur during severe impact events. Cavitation occurred in these experiments at accelerations greater than 150 g's. Head forms of different sizing will experience an acceleration magnitude inversely proportional to the size difference to produce a similar pressure/cavitation response.
Technical Paper

COMPARISON OF THE PRE-PROTOTYPE NHTSA ADVANCED DUMMY TO THE HYBRID III

1997-02-24
971141
A comparison of the NHTSA advanced dummy and the Hybrid III is presented in this paper based on their performance in twenty four frontal impact sled tests. Various time histories pertaining to accelerations, angular velocities, deflections and forces have been compared between the two dummies in light of their design differences. This has lead to some understanding about the differences and similarities between the NHTSA advanced dummy and the Hybrid III. In general, the chest as well as the head motion in the NHTSA advanced dummy are greater. The lumbar moments in the NHTSA advanced dummy are lower than that in the Hybrid III. The upper and lower spine segments in the NHTSA advanced dummy, generally rotate more than the spine of the Hybrid III.
Technical Paper

Insult to the Human Cadaver Patellofemoral Joint: Effects of Age on Fracture Tolerance and Occult Injury

1995-11-01
952729
Lower extremity (knee) trauma is currently based on a bone fracture criterion derived from impacts of aged specimens. Recent clinical studies, however, indicate that a chronic disease (post-traumatic osteoarthritis), may be precipitated after mechanical insult without obvious bone fracture(1). It is hypothesized this is due to microcracking of subchondral bone under cartilage. This hard tissue layer is known to change with age and pathology. Ten ‘aged’ (71 years) and ten ‘young’ (47 years) cadaver knee joints were impacted to study the influence of age and pathology on the fracture load, and incidents of occult injury. Our results indicate that fracture load, per se, was independent of specimen age. On the other hand, severely pathological specimens required significantly higher loads to fracture bone. Occult microcraking was also observed in subfracture experiments, however, fewer incidents were recorded for the ‘aged’ specimens.
Technical Paper

Critical Limitations on Significant Factors in Head Injury Research

1986-10-27
861890
The response of the head to blunt impact was investigated using anesthetized live and repressurized- and unrepressurized-postmortem Rhesus. The stationary test subject was struck on the occipital by a 10 kg guided moving impactor. The impactor striking surface was fitted with padding to vary the contact force-time characteristics. A nine-accelerometer system, rigidly affixed to the skull, measured head motion. Transducers placed at specific points below the skull recorded epidural pressure. The repressurization of postmortem subjects included repressurization of both the vascular and cerebrospinal systems.
Technical Paper

Thoraco-Abdominal Response to Steering Wheel Impacts

1985-12-01
851737
Mechanisms of thoraco-abdominal trauma were investigated utilizing unembalmed, repressurized human cadavers subjected to frontal impact with a steering wheel assembly. The focus of this research program was on trauma to the soft-tissue organs surrounded by the thoracic cage, as well as on the kinematic response of the thoracic cage. The results are compared to other thoraco-abdominal research programs conducted at the University of Michigan Transportation Research Institute (UMTRI) during the last eight years.
Technical Paper

UMTRI Experimental Techniques in Head Injury Research

1985-06-01
851244
This paper discusses techniques developed and used by the Biosciences Group at the University of Michigan Transportation Research Institute (UMTRI) for measuring three-dimensional head motion, skull bone strain, epidural pressure, and internal brain motion of repressurized cadavers and Rhesus monkeys during head impact. In the experimental design, a stationary test subject is struck by a guided moving impactor of 10 kg (monkeys) and 25 or 65 kg (cadavers). The impactor striking surface is fitted with padding to vary the contact force-time characteristics. The experimental technique uses a nine-accelerometer system rigidly affixed to the skull to measure head motion, transducers placed at specific points below the skull to record epidural pressure, repressurization of both the vascular and cerebrospinal systems, and high-speed cineradiography (at 1000 frames per second) of radiopaque targets.
X