Technical Paper

Comparison of PMHS, WorldSID, and THOR-NT Responses in Simulated Far Side Impact

2007-10-29
2012-01-1537
Injury to the far side occupant has been demonstrated as a significant portion of the total trauma in side impacts. The objective of the study was to determine the response of PMHS in far side impact configurations, with and without generic countermeasures, and compare responses to the WorldSID and THOR dummies. A far side impact buck was designed for a sled test system that included a center console and three-point belt system. The buck allowed for additional options of generic countermeasures including shoulder or thorax plates or an inboard shoulder belt. The entire buck could be mounted on the sled in either a 90-degree (3-o'clock PDOF) or a 60-degree (2-o'clock PDOF) orientation. A total of 18 tests on six PMHS were done to characterize the far side impact environment at both low (11 km/h) and high (30 km/h) velocities. WorldSID and THOR-NT tests were completed in the same configurations to conduct matched-pair comparisons.
Technical Paper

Thoracic Deformation Contours in a Frontal Impact

1991-10-01
912891
The objective of the study was to document the thoracic deformation contours in a simulated frontal impact. Unembalmed human cadavers and the Hybrid III anthropomorphic manikins were tested. Data from the newly developed External Peripheral Instrument for Deformation Measurement (EPIDM) was used to derive deformation patterns at upper and lower thoracic levels. Deceleration sled tests were conducted on three-point belt restrained surrogates positioned in the driver's seat (no steering assembly) using a horizontal impact test sled at velocities of approximately 14.0 m/s. Lap and shoulder belt forces were recorded with seat belt transducers. The experimental protocol included a Hybrid III manikin experiment followed by the human cadaver test. Both surrogates were studied under similar input and instrumentation conditions, and identical data acquisition and analysis procedures were used. All six testedcadavers demonstrated multiple bilateral rib fractures.
Technical Paper

The Translational Energy Criteria: A Validation Study for Non-Fracture Head Impacts

1997-11-12
973337
The development of the Translations Energy Criteria (TEC) has been underway for the last fifteen years. This criteria addresses brain contusion and skull fracture in the Anterior-Posterior (A-P), Left-Right (L-R), and Superior-Inferior (S-I) directions. The object of this strudy was to evaluate the ability of the TEC to predict non-fracture type injuries to the brain in the L-R and A-P directions up to the level of “serious.” Six unembalmed human cadavers were subjected to one head impact each. Tests one through three were frontal impacts, performed at 1.6, 3.9 and 6.7 m/s respectively. Tests four through six were lateral impacts, performed at 1.9, 3.8 and 6.1 m/s respectively. The impactor weighed 9.05 kg and was fitted with either a rigid or padded surface. The brain was repressurized and the head instrumented with two tri-axial linear accelerometer arrays and one angular velocity transducer. Two high speed motion picture views (1000 frames per second) were taken for each test.
Technical Paper

Biomechanical Assessment of Human Cervical Spine Ligaments

1998-11-02
983159
There is an increasing need to accurately define the soft tissue components of the human cervical spine in order to develop and exercise mathematical analogs such as the finite element model. Currently, a paucity of data exists in the literature and researchers have constantly underscored the need to obtain accurate data on cervical spine ligaments. Consequently, the objective of the study was to determine the geometrical and biomechanical properties of these ligaments from the axis to the first thoracic level. A total of thirty-three human cadavers were used in the study. Geometrical data included the length and cross-sectional area measurements; and the biomechanical properties included the force, deflection, stiffness, energy, stress, strain, and Young's modulus of elasticity data. Data were obtained for the following ligaments: anterior and posterior longitudinal ligaments, joint capsules, ligamentum flavum, and interspinous ligament.
Technical Paper

Response and Tolerance of the Human Forearm to Impact Loading

1998-11-02
983149
With the widespread use of supplemental restraint systems (airbags), occasional rare injuries have occurred because of the force associated with these systems upon deployment. Recent case studies have demonstrated forearm fractures associated with airbag deployment. The present study was conducted to determine the tolerance of the human forearm under a dynamic bending mode. A total of 30 human cadaver forearm specimens were tested using three-point bending protocol to failure at 3.3 m/s and 7.6 m/s velocities. Results indicated significantly (p < 0.01) greater biomechanical parameters associated with males compared to females. The bending tolerance of the human forearm, however, was found to be most highly correlated to bone mineral density, bone area, and forearm mass. Thus, any occupant with lower bone mineral density and lower forearm geometry/mass is at higher risk. The mean failure bending moment for all specimens was 94 Nm.
Technical Paper

Evaluation of lower limb injury mitigation from inflatable carpet in sled tests with intrusion using the Thor Lx

2001-06-04
2001-06-0092
Real-world crash investigations have suggested that lower limb injury risk is increased with the occurrence of toepan intrusion in a frontal collision. In order to more closely evaluate the effects of different modes of toepan intrusion, a rotational and translational intrusion device was built for the test sled at the University of Virginia. Sled tests were performed at a velocity of 56 km/h with a belted Hybrid III occupant and a simulated knee bolster and steering wheel air bag. Lower limb injury risk measures were obtained with Hybrid III and Thor Lx dummy lower extremities. Dummy response variables of interest included tibia axial and shear loads, tibia bending moments, ankle rotations and foot and tibia accelerations. The tests were conducted with no intrusion and with a translational intrusion with a peak deceleration of approximately 175 g's with 14 cm of translation.
Technical Paper

Biomechanics of Inertial Head-Neck Trauma: Role of Cervical Components

2002-03-19
2002-01-1445
Inertial loading of the head-neck complex occurs in rear impacts wherein the head and neck of the occupant are initially subjected to rearward forces. Epidemiological evidence exists to demonstrate the significance and societal impact of these injuries [4]. From a clinical perspective, trauma secondary to inertial loads belongs to the lower end of the Abbreviated Injury Scale, and no specific diagnostic techniques are available to quantitatively document the injury. Furthermore, identification of the mechanisms of injury and derivation of injury thresholds are limited. In fact, there is a paucity of literature focusing on the reproduction of rear impact-induced neck injuries due to a single-event rear impact. Because the impact acceleration is transmitted to the head from the torso via the cervical column, the components of the human neck play a role in the mechanics of trauma.
Technical Paper

Comparative Evaluation of Dummy Response with Thor-Lx/HIIIr and Hybrid III Lower Extremities

2002-03-04
2002-01-0016
Multiple series of frontal sled tests were performed to evaluate the new Thor-Lx/HIIIr lower extremity developed by the National Highway Traffic Safety Administration for retrofit use on the 50th percentile male Hybrid III. This study's objective was to compare the Thor-Lx/HIIIr to the existing Hybrid III dummy leg (HIII) from the standpoint of repeatability and effects on femur and upper body response values.\ The test-to-test repeatability of the dummy responses, as measured by the coefficient of variation (CV), was generally acceptable (CV < 10%) for all of the test conditions for both legs. Overall, tests with the Thor-Lx/HIIIr legs produced upper body movement and injury criteria values for the head and chest that were acceptably consistent and were generally indistinguishable from those produced with the HIII leg. Low right femur loads, which ranged from 4 to 25 percent of the injury assessment reference value, varied substantially test-to-test for tests with both types of legs.
Technical Paper

Load Distribution-Specific Viscoelastic Characterization of the Hybrid III Chest

2002-03-04
2002-01-0024
This paper presents a load distribution-specific viscoelastic structural characterization of the Hybrid III 50th percentile male anthropomorphic test dummy thorax. The dummy is positioned supine on a high-speed material testing machine and ramp-and-hold tests are performed using a distributed load, a hub load, and a diagonal belt load applied to the anterior thorax of the dummy. The force-deflection response is shown to be linear viscoelastic for all loading conditions when the internal dummy instrumentation is used to measure chest deflection. When an externally measured displacement (i.e., a measurement that includes the superficial skin material) is used for the characterization, a quasilinear viscoelastic characterization is necessary. Linear and quasilinear viscoelastic model coefficients are presented for all three loading conditions.
Technical Paper

Methodology for Measuring Tibial and Fibular Loads in a Cadaver

2002-03-04
2002-01-0682
Crash test dummies rely on biomechanical data from cadaver studies to biofidelically reproduce loading and predict injury. Unfortunately, it is difficult to obtain equivalent measurements of leg loading in a dummy and a cadaver, particularly for bending moments. A methodology is presented here to implant load cells in the tibia and fibula while minimally altering the functional anatomy of the two bones. The location and orientation of the load cells can be measured in all six degrees of freedom from post-test radiographs. Equations are given to transform tibial and fibular load cell measurements from a cadaver or dummy to a common leg coordinate frame so that test data can be meaningfully compared.
Technical Paper

Biodynamics of the Total Human Cadaveric Cervical Spine

1990-10-01
902309
Spinal trauma produced from motor vehicle accidents, diving accidents, or falls occur at high rates of loading. This study was undertaken to reproduce clinically relevant cervical spine injuries under controlled conditions. Six isolated head - T2 human cadaveric preparations were tested using an electrohydraulic piston actuator at loading rates from 295 to 813 cm/sec. The Hybrid III head-neck was tested similarly at rates from 401 to 683 cm/sec. The input forces for specimen tests were of higher magnitude and shorter duration than the distally measured forces. In contrast, the Hybrid III head-neck revealed similar magnitude and duration force traces from input to output. The specimen preparations were analyzed kinematically at 1200 frames/sec with 20 to 30 retroreflective targets fixed to each level of the cervical spine. With this technique it is possible to temporally follow cervical damage as a function of applied force.
Technical Paper

Thoracic Biomechanics with Air Bag Restraint

1993-11-01
933121
The objective of the present study was to determine the biomechanics of the human thorax in a simulated frontal impact. Fourteen unembalmed human cadavers were subjected to deceleration sled tests at velocities of nine or 13 m/s. Air bag - knee bolster, air bag - lap belt, and air bag - three-point belt restraint systems were used with the specimen positioned in the driver's seat. Two chest bands were used to derive the deformation patterns at the upper and lower thoracic levels. Lap and shoulder belt forces were recorded with seatbelt transducers. After the test, specimens were evaluated using palpation, radiography, and a detailed autopsy. Thoracic trauma was graded according to the Abbreviated Injury Scale based on autopsy findings. Peak thoracic deformations were normalized with respect to the initial chest depth to facilitate comparison between the specimens.
Technical Paper

Response of the Thor-Lx and Hybrid III Lower Extremities in Frontal Sled Tests

2003-03-03
2003-01-0161
The objectives of this study were to evaluate and compare the responses, repeatability, and durability of the Thor-Lx/HIIIr and Hybrid III/Denton lower extremities in frontal sled tests. Effectiveness of the two limb types was studied by evaluating responses in different test configurations using existing and proposed Injury Assessment Reference Values (IARVs) for both leg designs. Hybrid III or Thor-Lx legs were attached to the distal femurs of a 50th percentile male Hybrid III dummy, which was subjected to three series of 56 km/h frontal sled tests with and without toepan intrusion. Due to the design differences, many of the absolute response values were different between the Hybrid III and Thor-Lx legs. The expanded measurement capabilities, modified geometry and refined responses of the Thor-Lx limbs provide a more thorough and conservative judgment of injury risk.
Technical Paper

Biomechanical Analysis of Tractor Induced Head Injury

1994-09-01
941726
Head injury is a serious threat to lives of people working around farm machinery. The consequence of head injuries are costly, paralytic, and often fatal. Clinical and biomechanical data on head injuries are reviewed and their application in the analysis of head injury risk associated with farm tractor discussed. A significant proportion of tractor-related injuries and deaths to adults, as well as children, is due directly or indirectly to head injury. An improved injury reporting program and biomechanical studies of human response to tractor rollover, runover, and falls, are needed to understand mechanisms of the associated head injury.
Technical Paper

Thoracic Trauma Assessment Formulations for Restrained Drivers in Simulated Frontal Impacts

1994-11-01
942206
Sixty-three simulated frontal impacts using cadaveric specimens were performed to examine and quantify the performance of various contemporary automotive restraint systems. Test specimens were instrumented with accelerometers and chest bands to characterize their mechanical responses during the impact. The resulting thoracic injury severity was determined using detailed autopsy and was classified using the Abbreviated Injury Scale. The ability of various mechanical parameters and combinations of parameters to assess the observed injury severities was examined and resulted in the observation that belt restraint systems generally had higher injury rates than air bag restraint systems for the same level of mechanical responses. To provide better injury evaluations from observed mechanical parameters without prior knowledge of what restraint system was being used, a dichotomous process was developed.
Technical Paper

Dynamic Characteristics of the Human Cervical Spine

1995-11-01
952722
This paper presents the experimental dynamic tolerance and the force-deformation response corridor of the human cervical spine under compression loading. Twenty human cadaver head-neck complexes were tested using a crown impact to the head at speeds from 2.5 m/s to 8 m/s. The cervical spine was evaluated for pre-alignment by using the concept of the stiffest axis. Mid cervical column (C3 to C5) vertebral body wedge, burst, and vertical fractures were produced in compression. Posterior ligament tears in the lower column occurred under flexion. Anterior longitudinal ligament tears and spinous process fractures occurred under extension. Mean values were: force at failure, 3326 N; deformation at failure, 18 mm; stiffness, 555 N/mm. The deformation at failure parameter was associated with the least variance and should describe the most accurate tolerance measure for the population as a whole.
Technical Paper

Dynamic Axial Tolerance of the Human Foot-Ankle Complex

1996-11-01
962426
Axial loading of the calcaneus-talus-tibia complex is an important injury mechanism for moderate and severe vehicular foot-ankle trauma. To develop a more definitive and quantitative relationship between biomechanical parameters such as specimen age, axial force, and injury, dynamic axial impact tests to isolated lower legs were conducted at the Medical College of Wisconsin (MCW). Twenty-six intact adult lower legs excised from unembalmed human cadavers were tested under dynamic loading using a mini-sled pendulum device. The specimens were prepared, pretest radiographs were taken, and input impact and output forces together with the pathology were obtained using load cell data. Input impact forces always exceeded the forces recorded at the distal end of the preparation. The fracture forces ranged from 4.3 to 11.4 kN.
Technical Paper

Instrumentation of Human Surrogates for Side Impact

1996-11-01
962412
The purpose of this study was to investigate the use of the chestband in side impact conditions by conducting validation experiments, and evaluating its feasibility by conducting a series of human cadaver tests under side impact crash scenarios. The chestband validation tests were conducted by wrapping the device around the thorax section of the Side Impact Dummy at its uppermost portion. The anthropomorphic test device was seated on a Teflon pad on a platform to accept impact from the side via a pendulum system. Tests were conducted at 4.5, 5.7, and 6.7 m/sec velocities using round and flat impactors. Retroreflective targets were placed at each strain gauge channel on the edge of the chestband. The test was documented using a high-speed digital video camera operating at 4500 frames/sec. Deformation contours and histories were obtained using the chestband electronic signals in combination with the RBAND-PC software.
Technical Paper

A Pneumatic Airbag Deployment System for Experimental Testing

1997-02-24
970124
This paper examines an originally designed airbag deployment system for use in static experimental testing. It consists of a pressure vessel and valve arrangement with pneumatic and electric controls. A piston functions like a valve when operated and is activated pneumatically to release the air in the tank. Once released, the air fills the attached airbag. The leading edge velocity can be controlled by the initial pressure in the tank, which can range up to 960 kPa. Three different test configurations were studied, which resulted in leading edge deployment speeds of approximately 20 m/s, 40 m/s, and 60 m/s. In experiments using this system, seven types of airbags were tested that differed in their material, coating, and presence of a tether. Data for each series of tests is provided. High speed video and film were used to record the deployments, and a pressure transducer measured the airbag's internal pressure.
Technical Paper

Kinematic and Anatomical Analysis of the Human Cervical Spinal Column Under Axial Loading

1989-10-01
892436
The patho-anatomic alterations due to vertical loading of the human cervical column were documented and correlated with biomechanical kinematic data. Seven fresh human cadaveric head-neck complexes were prepared, and six-axis load cells were placed at the proximal and distal ends of the specimens to document the gross biomechanical response. Retroreflective markers were placed on bony landmarks of vertebral bodies, articular facets, and spinous processes along the entire cervical column. Targets were also placed on the occiput and arch of C1. The localized movements of these markers were recorded using a video analyzer during the entire loading cycle. Pre-test two-dimensional, and three-dimensional computerized tomography (CT), and plane radiographs were taken. The specimens were loaded to failure using an electrohydraulic testing device at a rate of 2 mm/s.