Technical Paper

Recent Advances in Brain Injury Research: A New Human Head Model Development and Validation

2001-11-01
2001-22-0017
Many finite element models have been developed by several research groups in order to achieve a better understanding of brain injury. Due to the lack of experimental data, validation of these models has generally been limited. Consequently, applying these models to investigate brain responses has also been limited. Over the last several years, several versions of the Wayne State University brain injury model (WSUBIM) were developed. However, none of these models is capable of simulating indirect impacts with an angular acceleration higher than 8,000 rad/s2. Additionally, the density and quality of the mesh in the regions of interest are not detailed and sensitive enough to accurately predict the stress/strain level associated with a wide range of impact severities. In this study, WSUBIM version 2001, capable of simulating direct and indirect impacts with a combined translational and rotational acceleration of the head up to 200 g and 12,000 rad/s2 has been developed.
Technical Paper

High-Speed Seatbelt Pretensioner Loading of the Abdomen

2006-11-06
2006-22-0002
This study characterizes the response of the human cadaver abdomen to high-speed seatbelt loading using pyrotechnic pretensioners. A test apparatus was developed to deliver symmetric loading to the abdomen using a seatbelt equipped with two low-mass load cells. Eight subjects were tested under worst-case scenario, out-of-position (OOP) conditions. A seatbelt was placed at the level of mid-umbilicus and drawn back along the sides of the specimens, which were seated upright using a fixed-back configuration. Penetration was measured by a laser, which tracked the anterior aspect of the abdomen, and by high-speed video. Additionally, aortic pressure was monitored. Three different pretensioner designs were used, referred to as system A, system B and system C. The B and C systems employed single pretensioners. The A system consisted of two B system pretensioners. The vascular systems of the subjects were perfused.
Technical Paper

Dynamic Impact Loading of the Femur Under Passive Restrained Condition

1984-10-01
841661
The biodynamic response of the femur during passively restrained -Gx impact acceleration is reported in this paper. Eleven unembalmed cadavers, ranging in age from 21 to 65 and weighing from 50 to 96 kg, were tested in a VW Rabbit seat with a passive belt and knee restraint. Sectioned parts of the VW knee bolster were placed about 130 mm away from the patella at the initiation of the tests. The height of the knee bolsters was adjusted individually in the eleven tests. Ten were set for loading directly through the patella. In one run, the impact was below the knee joint. The sectioned bolsters were mounted on a rigid frame and instrumented with triaxial load cells. A six-axis load cell was installed in the right femur. Photo targets were attached directly to the femur and tibia. Sled runs were made at 22 and 35 g. Only one cadaver sustained bilateral femoral fractures at 35 g.
Technical Paper

Dynamic Characteristics of the Human Spine During -Gx Acceleration

1978-02-01
780889
Spinal kinematics and kinetics of human cadaveric specimens subjected to -Gx acceleration are reported along with an attempt to design a surrogate spine for use in an anthropomorphic test device (ATD). There were a total of 30 runs on 9 embalmed and 2 unembalmed cadavers which were heavily instrumented. External photographic targets were attached to T1, T12, and the pelvis to record spinal kinematics. The subjects were restrained by upper and lower leg clamps attached to an impact seat equipped with a six-axis load cell. A rigid link 486 mm long and pinned at both ends was proposed for use in an ATD as a surrogate spine. An optimization method was used to obtain the location and length of a linkage which followed the least squares path of Tl relative to the pelvis.
Technical Paper

Development of a Three-Dimensional Finite Element Chest Model for the 5th Percentile Female

2005-11-09
2005-22-0012
Several three-dimensional (3D) finite element (FE) models of the human body have been developed to elucidate injury mechanisms due to automotive crashes. However, these models are mainly focused on 50th percentile male. As a first step towards a better understanding of injury biomechanics in the small female, a 3D FE model of a 5th percentile female human chest (FEM-5F) has been developed and validated against experimental data obtained from two sets of frontal impact, one set of lateral impact, two sets of oblique impact and a series of ballistic impacts. Two previous FE models, a small female Total HUman Model for Safety (THUMS-AF05) occupant version 1.0ϐ (Kimpara et al., 2002) and the Wayne State University Human Thoracic Model (WSUHTM, Wang 1995 and Shah et al., 2001) were integrated and modified for this model development.
Technical Paper

A Severe Ankle and Foot Injury in Frontal Crashes and Its Mechanism

1998-11-02
983145
In a frontal automotive crash, the driver's foot is usually stepping on the brake pedal as an instinctive response to avoid a collision. The tensile force generated in the Achilles tendon produces a compressive preload on the tibia. If there is intrusion of the toe board after the crash, an additional external force is applied to the driver's foot. A series of dynamic impact tests using human cadaveric specimens was conducted to investigate the combined effect of muscle preloading and external force. A constant tendon force was applied to the calcaneus while an external impact force was applied to the forefoot by a rigid pendulum. Preloading the tibia significantly increased the tibial axial force and the combination of these forces resulted in five tibial pylon fractures out of sixteen specimens.