Refine Your Search

Topic

Author

Affiliation

Search Results

Viewing 1 to 20 of 14556
Technical Paper

“Symbiose”: Technology Developments for Bioregeneration in Space

1994-06-01
941348
Dedicated technology has been developed to support long-term biological experiments on-board spacecraft. These developments include a microgravity compatible tubular photo bioreactor for the cultivation of micro algae at very high biomass concentrations and with very high gas exchange rates, a microgravity compatible gas / liquid phase separator which also works as a pneumatic low shear-stress pump, a microgravity compatible dehumidifier, and a maltose separating reverse osmosis unit. Integration of these technologies into a partially closed artificial ecosystem form the foundation of the SYMBIOSE concept (System for Microgravity Bioregenerative Support of Experiments).
Technical Paper

“Space-BEE: Space Biomedical Exercise Environment” A Personal Centrifuge within an Inflatable Structure

2005-07-11
2005-01-3049
This paper presents a conceptual design of a short-radius centrifuge for orbital application, contained in an inflatable structure. The objectives of this design are: to support the physical effectiveness of the crew by offering an exercise facility; to provide a test bed for biomedical experiments on human centrifugation in orbit; and to offer recreational benefits during long periods of confinement. The use of a pneumatic structure that can expand in orbit allows maximizing the radius of the centrifuge within mass and launch constraints. The proposed project is composed of elements with standard interfaces; its environmental design is based on human factor considerations from biomedical literature, and it respects current ergonomics and NASA standards.
Technical Paper

“Posture and Gait Control Enhancement Using Dermal Optical Sensitivity”

2004-07-19
2004-01-2484
Posture and gait controls underlie the fundamental physical and cognitive human factors necessary for astronauts’ safety and performance in Space. This central subsystem is adversely affected when exposed to an extreme or hostile environment. A specific stimulation, using dermal optical sensitivity, can be provided to the central nervous system to counteract peripheral stimulations due to microgravity as well as other negative stressors. We believe using dermal optical sensitivity-based stimulation can be key in the performance enhancement necessary to ensure human based space mission viability and success.
Technical Paper

“Personal Integrity” and Man-Machine Integration

1982-02-01
821348
A sense of “personal integrity” blocks pilot use of new information about how he thinks. Research on human performance under stress done over the past fifty years indicates increased rigidity and regression to earlier learned behavior in high stress, and in low Stress a shift in attention to any domestic situation or on the job controversy which is of higher stress than that of the job at hand, all without the pilot's knowledge. Informal surveys of commercial pilot training and commercial pilot attitudes towards these studies indicate that the study findings directly confront learned cultural responses. Pilot and trainer reactions prevent the information from being adequately investigated or formally taught. The findings are not written into training manuals and pilots who are informally given the information do not have adequate access to the knowledge when it is needed.
Technical Paper

“Greater Than the Sum of its Parts” Integrated Flight Training/Aircrew Coordination

1994-10-01
942132
The requirement for crew resource management (CRM), or aircrew coordination training (ACT) in military parlance, has been well documented and attested to. In addition, aircraft systems training has become more intense and more in-depth in the new aircraft designs, especially in multi-crew and complex aircraft such as the MV-22 Osprey Tiltrotor. (see Figure 1) Former training systems detailed training procedures that called for classroom training and simulation/simulator training followed by flight training. Improvements in aircraft flight skills training provide increased flying training capability coupled with reduced training time by integrating a mixed simulation/flight training syllabus, e.g. two to three simulation periods followed by one or two flight training periods covering the same material/skills. In addition, the simulation training will introduce new skills; the following flight periods will further refine/hone those skills.
Standard

electric Vertical Take Off and Landing (eVTOL) Emergency Lighting

2023-09-14
WIP
ARP8620
The purpose of this ARP is to provide criteria that will lead to and support existing regulatory standards of systems for UAM/AMM/eVTOL aircraft such that the emergency systems will facilitate egress under emergency conditions. Consideration is given to existing requirements of the FAA and to the recommendations of aircraft operators and those involved in the manufacture or use of the emergency lighting system. Occupant safety is the primary objective, with appropriate provisions for crew (pilot) system control taken into consideration. Consideration is also given to autonomous aircraft in which passengers are required to egress without the aid or direction of crew. The criteria established herein are intended to produce an emergency lighting system that will comply with the Federal and International Regulations. However, these recommendations are but one means of meeting the objective.
Technical Paper

considerations of some JET-DEFLECTION PRINCIPLES for - - directional control - - lift

1958-01-01
580062
THE performance characteristics of various devices applicable for jet directional control, lift augmentation, and VTOL-STOL studied at the NACA Lewis Laboratory are discussed, including jet deflection devices applicable to the conventonal round nozzle and novel nozzle configurations. The results indicate that many of the deflection devices applicable to conventional nozzles can readily be used for directional control or lift augmentation. Other deflection devices, such as movable plug, internal flap, cylindrical thrust reverser, swiveled primary with fixed shroud, and 90 deg side-bleed nozzle, are limited in application to jet directional control or aircraft trim because the loss in axial thrust for a given deflection force is prohibitive or the maximum deflected force obtainable is limited.
Technical Paper

Zn-Ni Plating as a Cadmium Alternative

2007-09-17
2007-01-3837
In a 2-year program sponsored by SJAC, an aqueous electroplating process using alkaline Zn-Ni with trivalent chromium post treatment is under evaluation for high strength steel for aircraft application as an alternative to cadmium. Commercial Zn-15%Ni rack/barrel plating solutions are basis for plating aircraft parts or fasteners. Brightener was reduced from the original formula to form porous plating that enables bake-out of hydrogen to avoid hydrogen embrittlement condition. Properties of the deposit, such as appearance, adhesion, un-scribed corrosion resistance, and galvanic corrosion resistance in contact with Al alloy, were evaluated. Coefficient of friction was compared with Cd plating by torque-tension measurements. Evaluation of the plating for scribed corrosion resistance, primer adhesion, etc. will continue in FY2007.
Standard

Zinc Phosphate Treatment Paint Base

2019-05-17
CURRENT
AMS2480J
This specification covers the requirements for producing a zinc phosphate coating on ferrous alloys and the properties of the coating.
Technical Paper

Zero-Waste PVD Cadmium for High Strength Steels

1998-11-11
983137
In spite of environmental issues related to cadmium and its electroplating process, electroplated cadmium is still extensively used in the aerospace and defense sectors. This trend is likely to continue especially for high strength steels because cadmium provides the best known corrosion and embrittlement protection for this application. Consequently, the environmental concerns related to the cadmium electroplating have been addressed using an alternative Zero-waste Physical Vapor Deposition (Z-PVD). This method does not use liquids, it recycles cadmium in situ, and is free of hydrogen embrittlement. The Z-PVD process is now in commercial production for the aerospace fasteners. The quality of the coatings has been at least equal to that of the electroplated cadmium.
Technical Paper

Zero-G Water Selection Separator: A Performance Tradeoff

1969-02-01
690642
This paper presents a trade-off study to select a water separator system for a 3-man, 140-day, zero-g mission. Included is a summary of feasible concepts, a compilation of data on existing hardware, and a comparison of the performance characteristics of each with respect to the overall system. Six approaches to zero-g water separation were considered and are discussed: hydrophobic/hydrophilic screens; integrated condenser-water separators; centrifugal separators; cellular sponges; vortex separators; and elbow separators. Some of these techniques have high-performance characteristics with regard to water removal efficiency. However, when reduced to hardware, these same techniques may not integrate well with the overall system. The system selected was the integrated condenser-water-separator. This system requires no power, has no moving parts, and has a very small envelope.
Technical Paper

Zero-G Simulation using Neutral Buoyancy

1989-07-01
891529
For human beings who have been reared on the earth with its 1 G gravitational field, the condition of weightlessness is a world with which we are unfamiliar. Even if the layout and equipment configuration of a spacecraft designed to compensate for operation under Zero-G conditions, there are some things which are not effective under actual weightless conditions. In the design of a manned spacecraft, it is necessary to accumulate design data on human performance in a weightless condition, then to undertake design evaluations and verification under weightless conditions. In this paper, testing for the purpose of evaluating the effectiveness of Zero-G simulation using neutral buoyancy, conducted first of all in Japan, and recommendations on the equipment and Facilities required to conduct such simulations, are described.
Standard

Zero Acceptance Number Sampling Procedures and Tables for Inspection by Attributes of A Continuous Manufacturing Process

2015-07-01
CURRENT
EIA584
Conventional attribute sampling plans based upon nonzero acceptance numbers are no longer desirable. In addition, emphasis is now placed on the quality level that is received by the customer. This relates directly to the Lot Tolerance Percent Defective (LTPD) value or the Limiting Quality Protection of MIL-STD-105. Measuring quality levels in percent nonconforming, although not incorrect, has been replaced with quality levels measured in parts per million (PPM). As a result, this standard addresses the need for sampling plans that can augment MIL-STD-105, are based upon a zero acceptance number, and address quality (nonconformance) levels in the parts per million range. This document does not address minor nonconformances, which are defined as nonconformances that are not likely to reduce materially the usability of the unit of product for its intended purpose.
Standard

ZINC PLATING

1991-10-01
HISTORICAL
AMS2402F
This specification covers the engineering requirements for electrodepositton of zinc and the properties of the deposit.
Technical Paper

ZERO-ODP REFRIGERANTS FOR LOW TONNAGE CENTRIFUGAL CHILLER SYSTEMS

1996-05-01
961320
This paper investigates the use of several zero-ozone depleting potential (zero-ODP) HFC refrigerants, including HFC-134a, HFC-227ca, HFC-227ea, HFC-236ea, HFC-236cb, HFC-236fa, HFC-245cb, and HFC-254cb, for centrifugal chiller applications. We took into account the thermodynamic properties of the refrigerant and aerodynamic characteristics of the impeller compression process in this evaluation.. For a given operating temperature lift, there are significant differences in the pressure ratio required by each refrigerant and this variation in pressure ratio directly affects compressor size, efficiency, and performance. A comparison of the HFC refrigerant candidates with CFC-114 shows that HFC-236ea, HFC-227ca and HFC-227ea are viable alternatives for centrifugal water chillers. HFC-236ea has properties closest to CFC-114, and will result in comparible performance, but will require a slightly larger impeller and a purge system.
X