Refine Your Search

Topic

Author

Affiliation

Search Results

Technical Paper

“Derivation of Conduction Heat Transfer in Thin Shell Toroids”

2000-07-10
2000-01-2487
This paper presents the derivation of the equations for circumferential, longitudinal and radial heat transfer conductance for a thin shell toroid or a segment of the toroid. A thin shell toroid is one in which the radius to thickness ratio is greater than 10. The equations for the surface area of a toroid or of a toroidal segment will also be derived along with the equation to determine the location of the centroid. The surface area is needed to determine the radial conductance in the toroid or toroidal segment and the centroid is needed to determine the heat transfer center of the toroid or toroidal segment for circumferential and longitudinal conductance. These equations can be used to obtain more accurate results for conductive heat transfer in toroid which is a curved spacecraft components. A comparison will be made (1) using the equations derived in this paper which takes into account the curvature of the toroid (true geometry) and (2) using flat plates to simulate the toroid.
Technical Paper

“Condensation – Why it Needs to be Addressed in Every Aircraft”

2003-09-08
2003-01-3000
A wide body aircraft carries almost a half–ton of water and ice between the cabin and skin of the aircraft. The water can get on wires and connectors, which can cause electrical problems, cause corrosion and rust, and, eventually, “rain in the plane”. The speaker is the CEO of CTT Systems that has developed a system that solves the condensation by using dry air. The speaker will discuss how condensation can be prevented and how airlines can also save maintenance costs in the process. This topic is relevant for the attendees at the Aerospace Expo, as they are decision makers who need to be aware of this issue. It is also important for the MRO shows as the attendees are on the front lines of dealing with this problem.
Technical Paper

‘Bigelow Aerospace® Life Support Laboratory - Planning and Status’

2004-07-19
2004-01-2474
This Life Support Laboratory consists of a simulator of the spacecraft called Nautilus, which houses Air Revitalization Subsystem, Atmospheric Control and Supply, and Fire Detection and Suppression in the Equipment Area. There are supporting facilities including a Human Metabolic Simulator, simulated Low and Moderate Temperature Coolant Loop, chemical analysis bench, purified water supply, vacuum and gas supplies. These facilities are scheduled to be completed and start to operate for demonstration purposes by March 2005. There are an ARES Ground Model (AGM) and a Trace Contaminant Control Assembly in the ARS. The latter will be integrated with the AGM and a Condensing Heat Exchanger. The unit of AGM is being engineered, built, and will be delivered in early 2005 by EADS Space Division. These assemblies will be operated for sensitivity analysis, integration and optimization studies. The main goal is the achievement for optimal recovery of oxygen.
Technical Paper

some development problems with Large Cryogenic Propellant Systems

1960-01-01
600022
HEAT TRANSFER causes loading and starting design problems in large missile systems powered by cryogenic propellants. This manifests itself during loading as effective density variation, violent surface conditions, boiloff, and ice formation — problems which may be solved by insulating the tank. During starting it causes overheating and caviation — effects which may be reduced by recirculators and subcooled charge injections. The study described in this paper centers around liquid oxygen and its variations in heat flux rate, which affect liquid density, surface condition, and replenishing requirements. The problem areas are made apparent by consideration of a hypothetical missile system.*
Technical Paper

Zone of Influence of Porous Suction Tubes in Condensing Heat Exchanger for Space Systems

2008-06-29
2008-01-2075
A “next generation” condensing heat exchanger for space systems has to satisfy demanding operational requirements under variable thermal and moisture loads and reduced gravity conditions. Mathematical models described here are used to investigate transient behavior of wetting and de-wetting dynamics in the binary porous system of porous tubes and porous cold plate. The model is based on the Richard's equation simplified for the zero-gravity conditions. The half-saturation distance or the zone of influence of the porous annular suction tubes on the cold-plate porous material will be in the range of 1 to 10 cm for the time scales ranging from 100 to 10,000 seconds and moisture diffusivity in the range of D = 10-4 to 10-6 m2/s.
Technical Paper

Zero-G Simulation using Neutral Buoyancy

1989-07-01
891529
For human beings who have been reared on the earth with its 1 G gravitational field, the condition of weightlessness is a world with which we are unfamiliar. Even if the layout and equipment configuration of a spacecraft designed to compensate for operation under Zero-G conditions, there are some things which are not effective under actual weightless conditions. In the design of a manned spacecraft, it is necessary to accumulate design data on human performance in a weightless condition, then to undertake design evaluations and verification under weightless conditions. In this paper, testing for the purpose of evaluating the effectiveness of Zero-G simulation using neutral buoyancy, conducted first of all in Japan, and recommendations on the equipment and Facilities required to conduct such simulations, are described.
Technical Paper

Zero Gravity Phase Separator Technologies - Past, Present and Future

1992-07-01
921160
Spacecraft life support equipment is often challenged with two phase flow, where liquid and gas exist together. In the zero gravity environment of an orbiting spacecraft, the behavior of a liquid/gas interface is dominated by forces not usually observed in one “G” due to the overwhelming effects of gravity. The normal perceptions no longer apply. Water does not run down hill and bubbles do not rise to the surface. Surface energy, capillary forces, wetting characteristics and momentum effects predominate. Techniques and equipment have been developed to separate the liquid/gas mixture into its constituent parts with various levels of efficiency and power consumption.
Standard

Zero Acceptance Number Sampling Procedures and Tables for Inspection by Attributes of A Continuous Manufacturing Process

2015-07-01
CURRENT
EIA584
Conventional attribute sampling plans based upon nonzero acceptance numbers are no longer desirable. In addition, emphasis is now placed on the quality level that is received by the customer. This relates directly to the Lot Tolerance Percent Defective (LTPD) value or the Limiting Quality Protection of MIL-STD-105. Measuring quality levels in percent nonconforming, although not incorrect, has been replaced with quality levels measured in parts per million (PPM). As a result, this standard addresses the need for sampling plans that can augment MIL-STD-105, are based upon a zero acceptance number, and address quality (nonconformance) levels in the parts per million range. This document does not address minor nonconformances, which are defined as nonconformances that are not likely to reduce materially the usability of the unit of product for its intended purpose.
Technical Paper

ZERO-ODP REFRIGERANTS FOR LOW TONNAGE CENTRIFUGAL CHILLER SYSTEMS

1996-05-01
961320
This paper investigates the use of several zero-ozone depleting potential (zero-ODP) HFC refrigerants, including HFC-134a, HFC-227ca, HFC-227ea, HFC-236ea, HFC-236cb, HFC-236fa, HFC-245cb, and HFC-254cb, for centrifugal chiller applications. We took into account the thermodynamic properties of the refrigerant and aerodynamic characteristics of the impeller compression process in this evaluation.. For a given operating temperature lift, there are significant differences in the pressure ratio required by each refrigerant and this variation in pressure ratio directly affects compressor size, efficiency, and performance. A comparison of the HFC refrigerant candidates with CFC-114 shows that HFC-236ea, HFC-227ca and HFC-227ea are viable alternatives for centrifugal water chillers. HFC-236ea has properties closest to CFC-114, and will result in comparible performance, but will require a slightly larger impeller and a purge system.
Technical Paper

XB-70A Laboratory for Progress

1966-02-01
660276
The development of the XB-70 research aircraft produced advancements in many fields of technology. This paper covers a few of these advancements in the areas of materials, equipment, and manufacturing. These include honeycomb construction, PH 15-7 alloy steel, vacuum melted H-11 steel, equipment capable of withstanding high temperatures, chemical milling of many different alloys, miniaturized welding equipment, and exothermic brazing techniques.
Technical Paper

XB-70 Ground Servicing and Safety Precautions

1966-02-01
660275
Planning for ground servicing and maintenance started in the proposal phase and has been followed by test program experience with the XB-70 Mach 3 air vehicle. Servicing and associated safety requirements are summarized. Discussion of maintenance and support actions includes mention of equipment provided to meet the requirements. Preflight, postflight, and periodic operations are outlined, along with some indication of changes that resulted when plans were put into practice. The demands of a high performance flight test air vehicle limit movements toward simplification.
Technical Paper

X-Ray Rocking Curve Analysis of the Aging and Deformation Characteristics in the Al-Li Alloy

1989-04-01
891057
A non-destructive x-ray technique, the double crystal diffractometer method, is presented as a tool to investigate the aging and deformation behavior of the Al-Li alloy. This is a sensitive method for measuring the strain and dislocation density within individual grains through the x-ray rocking curve. In addition, models were developed to describe the aging and deformation characteristics of this alloy.
Technical Paper

X-Ray - A Necessary Tool for Detecting Incipient Structural Failures in Service Aircraft

1964-01-01
640510
X-ray is an indispensable aid in locating and determining the extent of incipient failures in structure which is inaccessible by position or covered by multiple layers of metal. It is also the most feasible method for checking oil coolers for contamination; bonded honeycomb panels for water; fuel lines for erosion; and with a 360 deg emission tube, fuselage frames for structural integrity without removing the interior upholstery and panels from the passenger compartment or cargo compartments.
Technical Paper

X-29 Fuel/Auxiliary Oil Systems Thermal Management

1986-07-14
860913
The X-29 Fuel/Auxiliary Oil Thermal Management System provides total aircraft accessory oil cooling, including both flight and combined hydraulics, Integrated Drive Generator oil, and Accessory Drive Gearbox oil, with onboard fuel. Fuel cooling rates that are independent of engine demand are achieved through the use of a recirculation loop. Recirculation is minimized by maintaining the engine fuel inlet temperature at the maximum allowable. Fuel cooling results in lower, more uniform subsystem oil temperatures, less ram drag, and smaller, lighter-weight heat exchangers. Initial design studies and laboratory development testing will be discussed, along with comparisons of analytical predictions with flight test results.
X