Refine Your Search

Search Results

Technical Paper

Biofidelity Improvements to the Polar-II Pedestrian Dummy Lower Extremity

2007-04-16
2007-01-0757
Experimental tests were performed on the modified Polar-II pedestrian dummy lower extremity components to evaluate their biofidelity in lateral impact loading corresponding to a 40 km/h pedestrian-car collision. The bending moment-angle response from a newly developed knee joint, dynamically loaded in four-point valgus bending, was compared against previously published postmortem human subject (PMHS) response corridors. In addition to the stiffness characteristics of the knee joint, individual ligament forces were also recorded during the bending tests. The evaluated force-relative elongation response of the medial collateral ligament (MCL) in the new knee was compared against PMHS data on MCL tensile stiffness. Lower extremity long bones developed for improved anthropometrical accuracy and deformability were dynamically loaded in latero-medial three-point bending.
Technical Paper

Investigating Pedestrian Kinematics with the Polar-II Finite Element Model

2007-04-16
2007-01-0756
Previous full-scale pedestrian impact experiments using post-mortem human surrogates (PMHS) and sled-mounted vehicle bucks have shown that vehicle shape relative to pedestrian anthropometry may influence pedestrian kinematics and injury mechanisms. While a parametric study examining these factors could elucidate the complex relationships that govern pedestrian kinematics, it would be impractical with PMHS tests due to the relative expense involved in performing numerous experiments on subjects with varying anthropometry. Finite element (FE) modeling represents a more feasible approach since numerous experiments can be conducted with a fraction of the expense. However, there have been no studies to date depicting kinematic validation of a human pedestrian FE model in full-scale collisions using different vehicle and pedestrian geometries. Therefore, this study used an FE model of the Polar-II pedestrian dummy that was previously validated against full-scale test data.
Technical Paper

Thoracic Response to Shoulder Belt Loading: Investigation of Chest Stiffness and Longitudinal Strain Pattern of Ribs

2009-04-20
2009-01-0384
Two post-mortem human subjects were subjected to dynamic, non-injurious (up to 20% chest deflection) anterior shoulder belt loading at 0.5 m/s and 0.9 m/s loading rates. The human surrogates were mounted to a stationary apparatus that supported the spine and shoulder in a configuration comparable to that achieved in a 48 km/h sled test at the time of maximum chest deformation. A hydraulically driven shoulder belt was used to load the anterior thorax which was instrumented with a load cell for measuring reaction force and uniaxial strain gages at the 4th and 8th ribs. In addition, the deformation of the chest was measured using a 16- camera Vicon 3D motion capture system. In order to investigate the chest deformation pattern and ribcage loading in greater detail, a human finite element (FE) model of the thorax was used to simulate the tests.
Technical Paper

Assessment of the Thor and Hybrid III Crash Dummies: Steering Wheel Rim Impacts to the Upper Abdomen

2004-03-08
2004-01-0310
This investigation explored THOR's force-deflection response to upper abdomen/lower ribcage steering wheel rim impacts in comparison to the Hybrid III and cadaver test subjects. The stationary subjects were impacted by a ballasted surrogate wheel propelled at 4 m/s, a test condition designed to approximate the upper abdomen impacting a steering wheel rim in a frontal crash. Both the standard THOR and the Hybrid III crash dummies were substantially stiffer than the cadavers. Removing THOR's torso skin and foam from the upper abdomen and replacing the standard Hybrid III abdomen with a prototype gel-filled unit produced force-deflection results that were more similar to the cadavers. THOR offers advantages over the Hybrid III because of its ability to measure abdominal deflection. THOR, with modification, would be a useful instrument with which to assess the crashworthiness of steering assemblies and restraint systems in frontal crashes.
Technical Paper

Sled System Requirements for the Analysis of Side Impact Thoracic Injury Criteria and Occupant Protection

2001-03-05
2001-01-0721
This paper discusses struck-side occupant thoracic response to side-impact loading and the requirements of a sled system capable of reproducing the relevant motions of a laterally impacted vehicle. A simplified viscoelastic representation of a thorax is used to evaluate the effect of the door velocity-time profile on injury criteria and on the internal stress state of the thorax. Simulations using a prescribed door velocity-time profile (punch impact) are contrasted against simulations using a constant-velocity impact (Heidelberg-type impact). It is found that the stress distribution and magnitude within the thorax, in addition to the maximum thorax compression and viscous response, depend not only on the door-occupant closing velocity, but also on the shape of the door velocity-time profile throughout the time of contact with the occupant. A sled system capable of properly reproducing side-impact door and seat motion is described.
Technical Paper

Comparative Evaluation of Dummy Response with Thor-Lx/HIIIr and Hybrid III Lower Extremities

2002-03-04
2002-01-0016
Multiple series of frontal sled tests were performed to evaluate the new Thor-Lx/HIIIr lower extremity developed by the National Highway Traffic Safety Administration for retrofit use on the 50th percentile male Hybrid III. This study's objective was to compare the Thor-Lx/HIIIr to the existing Hybrid III dummy leg (HIII) from the standpoint of repeatability and effects on femur and upper body response values.\ The test-to-test repeatability of the dummy responses, as measured by the coefficient of variation (CV), was generally acceptable (CV < 10%) for all of the test conditions for both legs. Overall, tests with the Thor-Lx/HIIIr legs produced upper body movement and injury criteria values for the head and chest that were acceptably consistent and were generally indistinguishable from those produced with the HIII leg. Low right femur loads, which ranged from 4 to 25 percent of the injury assessment reference value, varied substantially test-to-test for tests with both types of legs.
Technical Paper

Load Distribution-Specific Viscoelastic Characterization of the Hybrid III Chest

2002-03-04
2002-01-0024
This paper presents a load distribution-specific viscoelastic structural characterization of the Hybrid III 50th percentile male anthropomorphic test dummy thorax. The dummy is positioned supine on a high-speed material testing machine and ramp-and-hold tests are performed using a distributed load, a hub load, and a diagonal belt load applied to the anterior thorax of the dummy. The force-deflection response is shown to be linear viscoelastic for all loading conditions when the internal dummy instrumentation is used to measure chest deflection. When an externally measured displacement (i.e., a measurement that includes the superficial skin material) is used for the characterization, a quasilinear viscoelastic characterization is necessary. Linear and quasilinear viscoelastic model coefficients are presented for all three loading conditions.
Technical Paper

Methodology for Measuring Tibial and Fibular Loads in a Cadaver

2002-03-04
2002-01-0682
Crash test dummies rely on biomechanical data from cadaver studies to biofidelically reproduce loading and predict injury. Unfortunately, it is difficult to obtain equivalent measurements of leg loading in a dummy and a cadaver, particularly for bending moments. A methodology is presented here to implant load cells in the tibia and fibula while minimally altering the functional anatomy of the two bones. The location and orientation of the load cells can be measured in all six degrees of freedom from post-test radiographs. Equations are given to transform tibial and fibular load cell measurements from a cadaver or dummy to a common leg coordinate frame so that test data can be meaningfully compared.
Technical Paper

Frequency Content Analysis and Filter Class Selection for the Small Female Instrumented Upper Extremity

2002-03-04
2002-01-0806
Although filter class specifications have been defined for most anthropomorphic test devices, no recommendation exists for the instrumented upper extremity. A three-part study was performed to determine the best channel filter class (CFC) to use for the instrumented upper extremity. By analyzing frequency content of signals from accelerometers and load cells, filtering data through three of the four possible CFC's to compare effects on the signals, and performing an injury comparison between cadaver data and the filtered load cell data, CFC 600 was chosen and recommended as the optimum filter class to use for upper extremity testing.
Technical Paper

Response of the Thor-Lx and Hybrid III Lower Extremities in Frontal Sled Tests

2003-03-03
2003-01-0161
The objectives of this study were to evaluate and compare the responses, repeatability, and durability of the Thor-Lx/HIIIr and Hybrid III/Denton lower extremities in frontal sled tests. Effectiveness of the two limb types was studied by evaluating responses in different test configurations using existing and proposed Injury Assessment Reference Values (IARVs) for both leg designs. Hybrid III or Thor-Lx legs were attached to the distal femurs of a 50th percentile male Hybrid III dummy, which was subjected to three series of 56 km/h frontal sled tests with and without toepan intrusion. Due to the design differences, many of the absolute response values were different between the Hybrid III and Thor-Lx legs. The expanded measurement capabilities, modified geometry and refined responses of the Thor-Lx limbs provide a more thorough and conservative judgment of injury risk.
Technical Paper

Comparison of Belted Hybrid III, THOR, and Cadaver Thoracic Responses in Oblique Frontal and Full Frontal Sled Tests

2003-03-03
2003-01-0160
This paper compares restrained Hybrid III and THOR thoracic kinematics and cadaver injury outcome in 30° oblique frontal and in full frontal sled tests. Peak shoulder belt tension, the primary source of chest loading, changed by less than four percent and peak chest resultant acceleration changed by less than 10% over the 30° range tested. Thoracic kinematics were likewise insensitive to the direction of the collision vector, though they were markedly different between the two dummies. Mid-sternal Hybrid III chest deflection, measured by the standard sternal potentiometer and by supplemental internal string potentiometers, was slightly lower (∼10%) in the oblique tests, but the oblique tests produced a negligible increase in lateral movement of the sternum. In an attempt to understand the biofidelity of these dummy responses, a series of 30-km/h human cadaver tests having several collision vectors (0°, 15°, 30°, 45°) was analyzed.
Technical Paper

Optical Measurement of High-Rate Dynamic Vehicle Roof Deformation during Rollover

2013-04-08
2013-01-0470
The goals of this study were to examine the dynamic force-deformation and kinematic response of a late model van subjected to an inverted drop test and to evaluate the accuracy of three-dimensional multi-point roof deformation measurements made by an optical system mounted inside the vehicle. The inverted drop test was performed using a dynamic rollover test system (Kerrigan et al., 2011 SAE) with an initial vehicle pitch of −5 degrees, a roll of +155 degrees and a vertical velocity of 2.7 m/s at initial contact. Measurements from the optical system, which was composed of two high speed imagers and a commercial optical processing software were compared to deformation measurements made by two sets of three string potentiometers. The optical and potentiometer measurements reported similar deformations: peak resultant deformations varied by 0.7 mm and 3 ms at the top of the A-pillar, and 1.7 mm and 2 ms at the top of the B-pillar.
Technical Paper

Development and Validation of a Finite Element Model for the Polar-II Upper Body

2006-04-03
2006-01-0684
The goal of this study was to develop and validate a finite element (FE) model of the Polar-II pedestrian dummy. An upper body model consisting of the head, neck, shoulder, thorax, and abdomen was coupled with a previously validated model of the lower limb The viscoelastic material properties of the dummy components were determined from dynamic compression tests of shoulder urethane, shoulder rubber and abdominal foam. For validation of the entire upper body, the model was compared with NHTSA response requirements for their advanced frontal dummy (Thor) including head and neck pendulum tests as well as ribcage and abdominal impact tests. In addition, the Polar-II full body FE model was subjected to simulated vehicle-pedestrian impacts that recreated published experiments. Simulated head and pelvis accelerations as well as upper body trajectories reasonably reproduced the experiment.
Technical Paper

Kinematic Analysis of Head/Neck Motion in Pedestrian-Vehicle Collisions Using 6-Degree-of-Freedom Instrumentation Cubes

2006-04-03
2006-01-0681
Given the quantity and severity of head injuries to pedestrians in vehicle-to-pedestrian collisions, human pedestrian finite element models and pedestrian dummies must possess a biofidelic head/neck response to accurately reproduce head-strike kinematics and kinetics. Full-scale pedestrian impact experiments were performed on post-mortem human surrogates (PMHS) using a mid-sized sport utility vehicle and a small sedan. Kinematics of the head and torso were obtained with a six-degree-of-freedom (6DOF) cube, which contained three orthogonally mounted linear accelerometers and three angular rate sensors. The goal of the current study was to present a methodology for analyzing the data obtained from the sensors on each cube, and to use the kinematics data to calculate spatial trajectories, as well as linear velocities and angular accelerations of the head and T1 vertebra.
Technical Paper

The Influence of Pelvis Design on the Lateral Pelvic Impact Response of the Polar-II Pedestrian Dummy

2006-04-03
2006-01-0682
Previous studies utilizing the Polar-II pedestrian dummy have suggested the need for a more biofidelic pelvis design in order to improve the overall dummy response kinematics. The current Polar-II dummy pelvis is a rigid steel structure. A preliminary version of a modified deformable pelvis equipped with sensors for measuring internal deflection and load has been designed. The goal of this study was to assess the biofidelity of these two pelves in full-scale tests with the Polar-II dummy that mimic lateral pelvic impact tests on PMHS (post-mortem human subjects) reported in the literature. The force - time, deflection - time, and force - deflection histories were compared to new PMHS response corridors determined using a normalization technique. In all tests with both pelves, the initial response (i.e., the first 3 ms to 5 ms following initial dummy - impactor contact) appeared to be totally determined by the mechanical behavior of the flesh.
Technical Paper

Design of a Full-Scale Impact System for Analysis of Vehicle Pedestrian Collisions

2005-04-11
2005-01-1875
The complexity of vehicle-pedestrian collisions necessitates extensive validation of pedestrian computational models. While body components can be individually simulated, overall validation of human pedestrian models requires full-scale testing with post mortem human surrogates (PMHS). This paper presents the development of a full-scale pedestrian impact test plan and experimental design that will be used to perform PMHS tests to validate human pedestrian models. The test plan and experimental design is developed based on the analysis of a combination of literature review, multi-body modeling, and epidemiologic studies. The proposed system has proven effective in testing an anthropometrically correct rescue dummy in multiple instances. The success of these tests suggests the potential for success in a full-scale pedestrian impact test using a PMHS.
Technical Paper

The Effects of Head Padding in Rear Facing Child Restraints

2005-04-11
2005-01-1839
Child restraint head padding is designed for the child's comfort under normal use. Under vehicle crash conditions, however, the padding in a rear facing child restraint may not be designed to sufficiently absorb impact energy. The objective of this paper is to evaluate the effects of various head padding conditions in rear facing child restraints in frontal impacts. Five sled tests were performed to measure the response of a CRABI 12 month dummy to different padding conditions in a rear facing child restraint. Static loading tests were performed on the padding materials. Results show that using padding of low stiffness increases head acceleration and HIC15 values.
Technical Paper

Dynamic Response Corridors of the Human Thigh and Leg in Non-Midpoint Three-Point Bending

2005-04-11
2005-01-0305
Current standards and test devices for pedestrian safety are developed using results from impact tests where inertial considerations have dominated and the vehicle pedestrian loading environment has not been properly replicated. When controlled tests have been conducted to evaluate the biofidelity of anthropometric test devices, current designs have faired poorly. The objective of the current study was to develop dynamic force-deflection and moment-deflection response corridors for the 50th percentile adult male thigh and leg subjected to non-midpoint 3-point bending at rates characteristic of the vehicle-pedestrian loading environment. Six thigh and eight leg specimens were harvested from eight adult male human cadavers and ramped to failure in dynamic 3-point bending in the latero-medial direction.
Technical Paper

Elimination of Thoracic Muscle Tensing Effects for Frontal Crash Dummies

2005-04-11
2005-01-0307
Current crash dummy biofidelity standards include the estimated effects of tensing the muscles of the thorax. This study reviewed the decision to incorporate muscle tensing by examining relevant past studies and by using an existing mathematical model of thoracic impacts. The study finds evidence that muscle tensing effects are less pronounced than implied by the biofidelity standard response corridors, that the response corridors were improperly modified to include tensing effects, and that tensing of other body regions, such as extremity bracing, may have a much greater effect on the response and injury potential than tensing of only the thoracic musculature. Based on these findings, it is recommended that muscle tensing should be eliminated from thoracic biofidelity requirements until there is sufficient information regarding multi-region muscle tensing response and the capability to incorporate this new data into a crash dummy.
Technical Paper

The Role of Axial Loading in Malleolar Fractures

2000-03-06
2000-01-0155
Though rotation is thought to be the most common mechanism of foot and ankle injury in both automobile crashes and in everyday life, axial impact loading is considered responsible for most severe lower extremity injuries. In this study, dynamic axial impact tests were conducted on 92 isolated human lower limbs. The test apparatus delivered the impact via a pendulum-driven plate which intruded longitudinally to simulate the motion of the toepan in an automobile crash. Magneto-hydrodynamic (MHD) angular rate sensors fixed to the limbs measured ankle rotations during the impact event. Malleolar or fibula fractures, which are commonly considered to be caused by excessive ankle rotation, were present in 38% (12 out of 32) of the injured specimens. Ankle rotations in these tests were always within 10° of neutral at the time of peak axial load and seldom exceeded failure boundaries reported in the literature at any point during the impact event.